Molectron
Information on Molectron / coherent laser power meters. Ultimately for the ezlaze project. I'm mostly interested in pyroelectric heads for pulsed power.
Contents
Ecosystem
Ecosystems:
- J DB-25 smart probes
- Interface: DB25
- Also known as JSA?
- 3sigma, FieldMax-TOP, FieldMax-TO, FieldMate.
- Intended to be used with J25, J50 power probes
- I also have an S10 energy probe, seems to be compatible
- LM DB-25 smart probes
- Interface: DB25
- Intended to be used with LM probes
Warning: J25 and LM are not compatible.
Lots of good info:
- Energy Sensors Coherent J25.pdf
- 2009_LMCCatalog86.pdf
There was a conversion box you could buy at one point though (thermal-smartsensor-adapter-data-sheet.pdf), so it might just be different EPROM format
- JSA-BNC Adapter
- 0012-2340: JSA-BNC Adapter for use with 3sigma, FieldMax-TOP, and FieldMax-P
- 1056827: SmartSensor Adapter for use with 3sigma, FieldMax-TOP, FieldMax-TO,and FieldMate
- Automatically configures itself to work with LM-model sensors
J25
TODO: figure out pinout, EEPROM format so I can recal and upgrade adapters
LM
3Sigma
File archive:
3sigmaAppQuickRef.pdf 3sigmaLVDriverUG.pdf 3sigma_LV_Driver.zip 3sigma Users Manual.pdf 3sigmaWinApps.zip
JD1000
Power supply: CS-1203000 (12V @ 3A, center positive)
McMaster
J25LP sensor
Came with JD1000. BNC output but no 25 pin adapter
Back:
MODEL NO: J25LP SERIAL NO: 238 RESPONSITIVITY 5.10 VOLT/JOULE 337.1 nm
S10 sensor
From 3Sigmal (eBay)
3Sigma output:
Probe Resp: 2.570E-1 A/W @ 514 nm Probe Cal Date Sep 10 2003 Wavelenth Corr 1064 nm / On Attenuation Corr: 1.00E0 / Off Area Corr 1.0000 sq cm / Off
DB25 label:
MODEL NO.: S10
J-25MB-HE sensor
3Sigma output:
FIXME
Cable label:
COHERENT Item# 1110748 Model: J-25MB-HE Serial#: 0984E07R
Responsitivity 6.694e + 0 V/J Cal 1064 nm
LM-10
LM-10 HTD 250-10600nm 10mW-10w 500mJ/cm2 10ns @ 1064n Laser
Relatively cheap impulse buy to compare EEPROM formats
3Sigma (eBay) meter
Came with CW sensor
3Sigma (dumpster dive) meter
Came w/ sensor + BNC adapter
Screen is messed up
Came with Lemo cable. Doesn't fit trigger ports or anything I can tell
JD1000 meter
Capacitor exploded when plugged in (presumably due to age). Didn't work after, although some lights turned on. Scrapped