= Part list =
+
=Part list=
  
== Model ==
+
==Model==
  
 
TODO: add standard metallurgical
 
TODO: add standard metallurgical
  
{| class="wikitable sortable" border=1
+
{| class="wikitable sortable" border="1"
! Image !! Name !! Description !! Notes
+
!Image!!Name!!Description!!Notes
 
|-
 
|-
| [[File:olympus_series_bh_microscope_system1.jpg|300 px]] <br />Source: [BH microscope, cover] [[BHA] || Bottom illumination, removable nosepiece ||
+
|[[File:olympus_series_bh_microscope_system1.jpg|300 px]] <br />Source: [BH microscope, cover] [[BHA]||Bottom illumination, removable nosepiece||
 
|-
 
|-
|   || [[BHB]] || Bottom illumination, fixed nosepiece ||
+
| ||[[BHB]]||Bottom illumination, fixed nosepiece||
 
|-
 
|-
|   || [[BHC]] || Bottom illumination, fixed nosepiece, integrated light source ||
+
| ||[[BHC]]||Bottom illumination, fixed nosepiece, integrated light source||
 
|-
 
|-
|   || [[BHMJ-02]] || Epi-illumination, sliding stanmd, BF, monocular ||
+
| ||[[BHMJ-02]]||Epi-illumination, sliding stanmd, BF, monocular||
 
|-
 
|-
|   || [[BHMJ-22]] || Epi-illumination, sliding stanmd, BF, binocular ||
+
| ||[[BHMJ-22]]||Epi-illumination, sliding stanmd, BF, binocular||
 
|-
 
|-
| [[File:olympus_bhmj_and_bhmj-n_bhmj.png|300 px]] <br />Source: [instruction BHMJ/-N, 3] [[BHMJ-42] ||   || Epi-illumination, sliding stanmd, BF, trinocular ||
+
|[[File:olympus_bhmj_and_bhmj-n_bhmj.png|300 px]] <br />Source: [instruction BHMJ/-N, 3] [[BHMJ-42]|| ||Epi-illumination, sliding stanmd, BF, trinocular||
 
|-
 
|-
|   || [[BHMJ-02-N]] || Epi-illumination, sliding stanmd, BF/DF, monocular ||
+
| ||[[BHMJ-02-N]]||Epi-illumination, sliding stanmd, BF/DF, monocular||
 
|-
 
|-
|   || [[BHMJ-22-N]] || Epi-illumination, sliding stanmd, BF/DF, binocular ||
+
| ||[[BHMJ-22-N]]||Epi-illumination, sliding stanmd, BF/DF, binocular||
 
|-
 
|-
|   || [[BHMJ-42-N]] || Epi-illumination, sliding stanmd, BF/DF, trinocular ||
+
| ||[[BHMJ-42-N]]||Epi-illumination, sliding stanmd, BF/DF, trinocular||
 
|-
 
|-
 
|}
 
|}
  
  
== Objective ==
+
==Objective==
  
 
M is BF only.  Neo are BF/DF.  All are M25 threaded
 
M is BF only.  Neo are BF/DF.  All are M25 threaded
  
{| class="wikitable sortable" border=1
+
{| class="wikitable sortable" border="1"
! Image !! Part # !! Type !! Description !! Notes
+
!Image!!Part #!!Type!!Description!!Notes
 
|-
 
|-
|   || [[M5X]] || Objective || 5x ||
+
| ||[[M5X]]||Objective||5x||
 
|-
 
|-
|   || [[M10X]] || Objective || 10x ||
+
| ||[[M10X]]||Objective||10x||
 
|-
 
|-
|   || [[M20X]] || Objective || 20x ||
+
| ||[[M20X]]||Objective||20x||
 
|-
 
|-
|   || [[M40X]] || Objective || 40x ||
+
| ||[[M40X]]||Objective||40x||
 
|-
 
|-
|   || [[Neo5X]] || Objective || 5x ||
+
| ||[[Neo5X]]||Objective||5x||
 
|-
 
|-
|   || [[Neo10X]] || Objective || 10x ||
+
| ||[[Neo10X]]||Objective||10x||
 
|-
 
|-
|   || [[Neo20X]] || Objective || 20x ||
+
| ||[[Neo20X]]||Objective||20x||
 
|-
 
|-
|   || [[Neo40X]] || Objective || 40x ||
+
| ||[[Neo40X]]||Objective||40x||
 
|-
 
|-
|   || [[BH-RE]] || Nosepiece   || Quintuple ||
+
| ||[[BH-RE]]||Nosepiece||Quintuple||
 
|-
 
|-
|   || [[BH-RE]] || Nosepiece ||   ||
+
| ||[[BH-RE]]||Nosepiece|| ||
 
|-
 
|-
|   || [[BH-NRE]] || Nosepiece ||   ||
+
| ||[[BH-NRE]]||Nosepiece|| ||
 
|-
 
|-
 
|}
 
|}
  
  
== Illuminator ==
+
==Illuminator==
  
{| class="wikitable sortable" border=1
+
{| class="wikitable sortable" border="1"
! Image !! Part # !! Type !! Description !! Notes
+
!Image!!Part #!!Type!!Description!!Notes
 
|-
 
|-
|   || [[BH-MA]] || Illuminator (vertical) || Brightfield ||
+
| ||[[BH-MA]]||Illuminator (vertical)||Brightfield||
 
|-
 
|-
|   || [[BH-RLA]] || Illuminator (vertical) || Brightfield and darkfield ||
+
| ||[[BH-RLA]]||Illuminator (vertical)||Brightfield and darkfield||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bh-lh.png|300 px]] <br />Source: [BH microscope, 9] [[BH-LH] || Lamphouse || Tungsten, 30W || Pre-centered
+
|[[File:olympus_series_bh_microscope_bh-lh.png|300 px]] <br />Source: [BH microscope, 9] [[BH-LH]||Lamphouse||Tungsten, 30W||Pre-centered
 
|-
 
|-
|   || [[BH-LHM]] || Lamphouse || Tungsten ||
+
| ||[[BH-LHM]]||Lamphouse||Tungsten||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bh-lsh.png|300 px]] <br />Source: [BH microscope, 9] [[BH-LSH] || Lamphouse || Halogen 100W || Centerable
+
|[[File:olympus_series_bh_microscope_bh-lsh.png|300 px]] <br />Source: [BH microscope, 9] [[BH-LSH]||Lamphouse||Halogen 100W||Centerable
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bh-lh.png|300 px]] <br />Source: [BH microscope, 9] [[BH-LH] || Lamphouse ||   ||
+
|[[File:olympus_series_bh_microscope_bh-lh.png|300 px]] <br />Source: [BH microscope, 9] [[BH-LH]||Lamphouse|| ||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_ls30.png|100 px]] <br />Source: [BH microscope, 9] [[LS30] || Bulb || 6V, 30W tungsten ||
+
|[[File:olympus_series_bh_microscope_ls30.png|100 px]] <br />Source: [BH microscope, 9] [[LS30]||Bulb||6V, 30W tungsten||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_ls15.png|100 px]] <br />Source: [BH microscope, 9] [[LS15] || Bulb || 6V, 15W tungsten ||
+
|[[File:olympus_series_bh_microscope_ls15.png|100 px]] <br />Source: [BH microscope, 9] [[LS15]||Bulb||6V, 15W tungsten||
 
|-
 
|-
|   || [[FK5X]] || Eyepiece, photo || 5x ||
+
| ||[[FK5X]]||Eyepiece, photo||5x||
 
|-
 
|-
|   || [[TF]] || Power supply || Transformer || voltage range?
+
| ||[[TF]]||Power supply||Transformer||voltage range?
 
|-
 
|-
|   || [[45C]] || Filter || for what? ||
+
| ||[[45C]]||Filter||for what?||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_jc12v_100w.png|150 px]] <br />Source: [BH microscope, 9] [[jc12v 100W] || Bulb || Halogen ||
+
|[[File:olympus_series_bh_microscope_jc12v_100w.png|150 px]] <br />Source: [BH microscope, 9] [[jc12v 100W]||Bulb||Halogen||
 
|-
 
|-
 
|}
 
|}
  
  
== Observation tube ==
+
==Observation tube==
  
{| class="wikitable sortable" border=1
+
{| class="wikitable sortable" border="1"
! Image !! Part # !! Type !! Description !! Notes
+
!Image!!Part #!!Type!!Description!!Notes
 
|-
 
|-
|   || [[CH-M045]] || Observation tube || Monocular ||
+
| ||[[CH-M045]]||Observation tube||Monocular||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bh-swtr.png|300 px]] <br />Source: [BH microscope, 11] [[BH-SWTR] || Observation tube || Binocular w/ photo? ||
+
|[[File:olympus_series_bh_microscope_bh-swtr.png|300 px]] <br />Source: [BH microscope, 11] [[BH-SWTR]||Observation tube||Binocular w/ photo?||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bh-bi30_bi45.png|300 px]] <br />Source: [BH microscope, 11] [[BH-BI30] || Observation tube || Binocular, 30 degree ||
+
|[[File:olympus_series_bh_microscope_bh-bi30_bi45.png|300 px]] <br />Source: [BH microscope, 11] [[BH-BI30]||Observation tube||Binocular, 30 degree||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bh-bi30_bi45.png|300 px]] <br />Source: [BH microscope, 11] [[BH-BI45] || Observation tube || Binocular, 45 degree ||
+
|[[File:olympus_series_bh_microscope_bh-bi30_bi45.png|300 px]] <br />Source: [BH microscope, 11] [[BH-BI45]||Observation tube||Binocular, 45 degree||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bh-tr30_tr45.png|300 px]] <br />Source: [BH microscope, 11] [[BH-TR30] || Observation tube || Binocular, 30 degree (w/ photo) ||
+
|[[File:olympus_series_bh_microscope_bh-tr30_tr45.png|300 px]] <br />Source: [BH microscope, 11] [[BH-TR30]||Observation tube||Binocular, 30 degree (w/ photo)||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bh-tr30_tr45.png|300 px]] <br />Source: [BH microscope, 11] [[BH-TR45] || Observation tube || Binocular, 45 degree (w/ photo) ||
+
|[[File:olympus_series_bh_microscope_bh-tr30_tr45.png|300 px]] <br />Source: [BH microscope, 11] [[BH-TR45]||Observation tube||Binocular, 45 degree (w/ photo)||
 
|-
 
|-
|   || [[BiWF10X]] || Eyepiece || HEP, paired ||
+
| ||[[BiWF10X]]||Eyepiece||HEP, paired||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_emm-vi.png|300 px]] <br />Source: [BH microscope, 15] [[EMM-VI] ||   ||   ||
+
|[[File:olympus_series_bh_microscope_emm-vi.png|300 px]] <br />Source: [BH microscope, 15] [[EMM-VI]|| || ||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_pm-10-35a.png|300 px]] <br />Source: [BH microscope, 15] [[PM-10-35A] ||   ||   ||
+
|[[File:olympus_series_bh_microscope_pm-10-35a.png|300 px]] <br />Source: [BH microscope, 15] [[PM-10-35A]|| || ||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_pm-10-35l2a.png|300 px]] <br />Source: [BH microscope, 15] [[PM-10-35L2A] ||   ||   ||
+
|[[File:olympus_series_bh_microscope_pm-10-35l2a.png|300 px]] <br />Source: [BH microscope, 15] [[PM-10-35L2A]|| || ||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_pm-10-35m.png|300 px]] <br />Source: [BH microscope, 15] [[PM-10-35M] ||   ||   ||
+
|[[File:olympus_series_bh_microscope_pm-10-35m.png|300 px]] <br />Source: [BH microscope, 15] [[PM-10-35M]|| || ||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_pm-6.png|300 px]] <br />Source: [BH microscope, 15] [[PM-6] ||   ||   ||
+
|[[File:olympus_series_bh_microscope_pm-6.png|300 px]] <br />Source: [BH microscope, 15] [[PM-6]|| || ||
 
|-
 
|-
 
|}
 
|}
  
  
== Misc ==
+
==Misc==
  
{| class="wikitable sortable" border=1
+
{| class="wikitable sortable" border="1"
! Image !! Part # !! Type !! Description !! Notes
+
!Image!!Part #!!Type!!Description!!Notes
 
|-
 
|-
| [[File:zoidberg_bh_neo_turret.jpg|200 px]] [[BH-RE] || Nosepiece   || Quintuple || Neo objectives (M25)
+
|[[File:zoidberg_bh_neo_turret.jpg|200 px]] [[BH-RE]||Nosepiece||Quintuple||Neo objectives (M25)
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bha-f.png|300 px]] <br />Source: [BH microscope, 9] [[BHA-F] || Stand || Bottom illumination, removable nosepiece ||
+
|[[File:olympus_series_bh_microscope_bha-f.png|300 px]] <br />Source: [BH microscope, 9] [[BHA-F]||Stand||Bottom illumination, removable nosepiece||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bhb-f.png|300 px]] <br />Source: [BH microscope, 9] [[BHB-F] || Stand || Bottom illumination, fixed nosepiece ||
+
|[[File:olympus_series_bh_microscope_bhb-f.png|300 px]] <br />Source: [BH microscope, 9] [[BHB-F]||Stand||Bottom illumination, fixed nosepiece||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bhc-f.png|300 px]] <br />Source: [BH microscope, 9] [[BHC-F] || Stand || Bottom illumination, fixed nosepiece, integrated light || Lowest cost?
+
|[[File:olympus_series_bh_microscope_bhc-f.png|300 px]] <br />Source: [BH microscope, 9] [[BHC-F]||Stand||Bottom illumination, fixed nosepiece, integrated light||Lowest cost?
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bh-sv.png|300 px]] <br />Source: [BH microscope, 13] [[BH-SV] || Stage ||   ||
+
|[[File:olympus_series_bh_microscope_bh-sv.png|300 px]] <br />Source: [BH microscope, 13] [[BH-SV]||Stage|| ||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bh-cd.png|300 px]] <br />Source: [BH microscope, 13] [[BH-CD] || Condenser || Abbe ||
+
|[[File:olympus_series_bh_microscope_bh-cd.png|300 px]] <br />Source: [BH microscope, 13] [[BH-CD]||Condenser||Abbe||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bh-aac.png|300 px]] <br />Source: [BH microscope, 13] [[BH-AAC] || Condenser || Ach/Apla ||
+
|[[File:olympus_series_bh_microscope_bh-aac.png|300 px]] <br />Source: [BH microscope, 13] [[BH-AAC]||Condenser||Ach/Apla||
 
|-
 
|-
|   || [[BHMJ-ST]], [[BHMJ-F]] || Body/base ||
+
| ||[[BHMJ-ST]], [[BHMJ-F]]||Body/base||
 
|-
 
|-
|   || [[FK3.3X]] || Photo eyepiece ||   ||
+
| ||[[FK3.3X]]||Photo eyepiece|| ||
 
|-
 
|-
|   || [[32.5C]] || Blue filter ||
+
| ||[[32.5C]]||Blue filter||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_ah-ca.png|300 px]] <br />Source: [BH microscope, 11] [[AH-CA] ||   ||
+
|[[File:olympus_series_bh_microscope_ah-ca.png|300 px]] <br />Source: [BH microscope, 11] [[AH-CA]|| ||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_ah-fa.png|300 px]] <br />Source: [BH microscope, 11] [[AH-FA] ||   ||
+
|[[File:olympus_series_bh_microscope_ah-fa.png|300 px]] <br />Source: [BH microscope, 11] [[AH-FA]|| ||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bh-dcd.png|300 px]] <br />Source: [BH microscope, 13] [[BH-DCD] ||   ||
+
|[[File:olympus_series_bh_microscope_bh-dcd.png|300 px]] <br />Source: [BH microscope, 13] [[BH-DCD]|| ||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bh-dcw.png|300 px]] <br />Source: [BH microscope, 13] [[BH-DCW] ||   ||
+
|[[File:olympus_series_bh_microscope_bh-dcw.png|300 px]] <br />Source: [BH microscope, 13] [[BH-DCW]|| ||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bh-pc.png|300 px]] <br />Source: [BH microscope, 13] [[BH-PC] ||   ||
+
|[[File:olympus_series_bh_microscope_bh-pc.png|300 px]] <br />Source: [BH microscope, 13] [[BH-PC]|| ||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bh-sh.png|300 px]] <br />Source: [BH microscope, 13] [[BH-SH] ||   ||
+
|[[File:olympus_series_bh_microscope_bh-sh.png|300 px]] <br />Source: [BH microscope, 13] [[BH-SH]|| ||
 
|-
 
|-
| [[File:olympus_series_bh_microscope_bh-swc.png|300 px]] <br />Source: [BH microscope, 13] [[BH-SWC] ||   ||
+
|[[File:olympus_series_bh_microscope_bh-swc.png|300 px]] <br />Source: [BH microscope, 13] [[BH-SWC]|| ||
 
|-
 
|-
 
|}
 
|}
  
  
 
+
=BHA/BHB/BHC configurations=
= BHA/BHB/BHC configurations =
 
  
 
[[File:olympus_series_bh_microscope_system1.jpg|300 px]]
 
[[File:olympus_series_bh_microscope_system1.jpg|300 px]]
Line 180: Line 179:
 
NOTE: -1, -2, etc are my notation for the color columns in [BH microscope, 18]
 
NOTE: -1, -2, etc are my notation for the color columns in [BH microscope, 18]
  
{| class="wikitable sortable" border=1
+
{| class="wikitable sortable" border="1"
! Part # !! Type !! Description !! BHA-1 !! BHA-2 !! BHA-3 !! BHA-4 !! BHB-1 !! BHB-2 !! BHB-3 !! BHB-4 !! BHC-1 !! BHC-2
+
!Part #!!Type!!Description!!BHA-1!!BHA-2!!BHA-3!!BHA-4!!BHB-1!!BHB-2!!BHB-3!!BHB-4!!BHC-1!!BHC-2
 
|-
 
|-
| [[BHA-F]] || Stand ||   || Y || Y || Y || Y ||   ||   ||   ||   ||   ||
+
|[[BHA-F]]||Stand|| ||Y||Y||Y||Y|| || || || || ||
 
|-
 
|-
| [[BHB-F]] || Stand ||   ||   ||   ||   ||   || Y || Y || Y || Y ||   ||
+
|[[BHB-F]]||Stand|| || || || || ||Y||Y||Y||Y|| ||
 
|-
 
|-
| [[BHC-F]] || Stand ||   ||   ||   ||   ||   ||   ||   ||   ||   || Y || Y
+
|[[BHC-F]]||Stand|| || || || || || || || || ||Y||Y
 
|-
 
|-
| [[BH-RE]] || Nosepiece   || Quintuple || Y || Y || Y || Y ||   ||   ||   ||   ||   ||
+
|[[BH-RE]]||Nosepiece||Quintuple||Y||Y||Y||Y|| || || || || ||
 
|-
 
|-
| [[BH-LH]] || Lamphouse ||   || Y || Y || Y || Y || Y || Y || Y || Y ||   ||
+
|[[BH-LH]]||Lamphouse|| ||Y||Y||Y||Y||Y||Y||Y||Y|| ||
 
|-
 
|-
| [[LS30]] || Bulb || 6V, 30W || Y || Y || Y || Y || Y || Y || Y || Y ||   ||
+
|[[LS30]]||Bulb||6V, 30W||Y||Y||Y||Y||Y||Y||Y||Y|| ||
 
|-
 
|-
| [[LS15]] || Bulb || 6V, 15W ||   ||   ||   ||   ||   ||   ||   ||   || Y || Y
+
|[[LS15]]||Bulb||6V, 15W|| || || || || || || || ||Y||Y
 
|-
 
|-
| [[BH-BI45]] || Observation tube || 45 deg binocular ||   || Y ||   || Y ||   || Y ||   || Y ||   || Y
+
|[[BH-BI45]]||Observation tube||45 deg binocular|| ||Y|| ||Y|| ||Y|| ||Y|| ||Y
 
|-
 
|-
| [[BH-TR45]] || Observation tube || 45 deg trinocular || Y ||   || Y ||   || Y ||   || Y ||   || Y ||
+
|[[BH-TR45]]||Observation tube||45 deg trinocular||Y|| ||Y|| ||Y|| ||Y|| ||Y||
 
|-
 
|-
| [[BH-SV]] || Stage ||   || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y
+
|[[BH-SV]]||Stage|| ||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y
 
|-
 
|-
| [[BH-CD]] || Condenser || Abbe ||   ||   || Y || Y || Y || Y || Y || Y || Y || Y
+
|[[BH-CD]]||Condenser||Abbe|| || ||Y||Y||Y||Y||Y||Y||Y||Y
 
|-
 
|-
| [[BH-AAC]] || Condenser || Ach/Apla || Y || Y ||   ||   ||   ||   ||   ||   ||   ||
+
|[[BH-AAC]]||Condenser||Ach/Apla||Y||Y|| || || || || || || ||
 
|-
 
|-
|   || Objective || Achromat 4x, 10x, S-40x (spring), S-100x (spring, oil) set ||   ||   || Y || Y ||   ||   || Y || Y || Y || Y
+
| ||Objective||Achromat 4x, 10x, S-40x (spring), S-100x (spring, oil) set|| || ||Y||Y|| || ||Y||Y||Y||Y
 
|-
 
|-
|   || Objective || Plan achromat 4x, 10x, 40x (spring), 100x (spring, oil) set || Y || Y ||   ||   || Y || Y ||   ||   ||   ||
+
| ||Objective||Plan achromat 4x, 10x, 40x (spring), 100x (spring, oil) set||Y||Y|| || ||Y||Y|| || || ||
 
|-
 
|-
|   || Objective || Plan achromat 20x (spring) || Y || Y ||   ||   ||   ||   ||   ||   ||   ||
+
| ||Objective||Plan achromat 20x (spring)||Y||Y|| || || || || || || ||
 
|-
 
|-
| [[BiWF10X]] || Eyepiece || HEP, paired || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y
+
|[[BiWF10X]]||Eyepiece||HEP, paired||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y
 
|-
 
|-
| [[FK5X]] || Eyepiece, photo || 5x || Y ||   || Y ||   || Y ||   || Y ||   || Y ||
+
|[[FK5X]]||Eyepiece, photo||5x||Y|| ||Y|| ||Y|| ||Y|| ||Y||
 
|-
 
|-
| [[45C]] || Filter || for what? ||   ||   ||   ||   ||   ||   ||   ||   ||   ||
+
|[[45C]]||Filter||for what?|| || || || || || || || || ||
 
|-
 
|-
|   || Bulb || Spare bulb (2x) || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y
+
| ||Bulb||Spare bulb (2x)||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y
 
|-
 
|-
|   || Fuse || Spare fuse (2x) || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y
+
| ||Fuse||Spare fuse (2x)||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y
 
|-
 
|-
|   || Oil || Immersion oil || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y
+
| ||Oil||Immersion oil||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y
 
|-
 
|-
|   || Cover || Vintyl dust cover || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y
+
| ||Cover||Vintyl dust cover||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y
 
|-
 
|-
 
|}
 
|}
  
  
= BHMJ configurations =
+
=BHMJ configurations=
  
 
[[File:olympus_bhmj_and_bhmj-n_bhmj.png|300 px]]
 
[[File:olympus_bhmj_and_bhmj-n_bhmj.png|300 px]]
Line 240: Line 239:
 
-N adds darkfield
 
-N adds darkfield
  
{| class="wikitable sortable" border=1
+
{| class="wikitable sortable" border="1"
! Part # !! Type !! Description !! BHMJ-02 !! BHMJ-22 !! BHMJ-42 !! BHMJ-02-N !! BHMJ-22-N !! BHMJ-42-N
+
!Part #!!Type!!Description!!BHMJ-02!!BHMJ-22!!BHMJ-42!!BHMJ-02-N!!BHMJ-22-N!!BHMJ-42-N
 
|-
 
|-
| [[BHMJ-ST]], [[BHMJ-F]] || Body/base ||   || Y || Y || Y || Y || Y || Y
+
|[[BHMJ-ST]], [[BHMJ-F]]||Body/base|| ||Y||Y||Y||Y||Y||Y
 
|-
 
|-
| [[BH-RE]] || Nosepiece ||   || Y || Y || Y ||   ||   ||
+
|[[BH-RE]]||Nosepiece|| ||Y||Y||Y|| || ||
 
|-
 
|-
| [[BH-NRE]] || Nosepiece ||     ||   ||   ||   || Y || Y || Y
+
|[[BH-NRE]]||Nosepiece|| || || || ||Y||Y||Y
 
|-
 
|-
| [[BH-MA]] || Illuminator (vertical) || Brightfield || Y || Y || Y ||   ||   ||
+
|[[BH-MA]]||Illuminator (vertical)||Brightfield||Y||Y||Y|| || ||
 
|-
 
|-
| [[BH-RLA]] || Illuminator (vertical) || Brightfield and darkfield ||   ||   ||   || Y || Y || Y
+
|[[BH-RLA]]||Illuminator (vertical)||Brightfield and darkfield|| || || ||Y||Y||Y
 
|-
 
|-
| [[CH-M045]] || Observation tube || Monocular   || Y ||   ||   || Y ||   ||
+
|[[CH-M045]]||Observation tube||Monocular||Y|| || ||Y|| ||
 
|-
 
|-
| [[BH-BI45]] || Observation tube || Monocular ||   || Y ||   ||   || Y ||
+
|[[BH-BI45]]||Observation tube||Monocular|| ||Y|| || ||Y||
 
|-
 
|-
| [[BH-TR45]] || Observation tube || Binocular (w/ photo) ||   ||   || Y ||   ||   || Y
+
|[[BH-TR45]]||Observation tube||Binocular (w/ photo)|| || ||Y|| || ||Y
 
|-
 
|-
| [[BH-LHM]] || Lamphouse || Tungsten || Y || Y || Y || Y || Y || Y
+
|[[BH-LHM]]||Lamphouse||Tungsten||Y||Y||Y||Y||Y||Y
 
|-
 
|-
| [[LS15]] || Bulb || 15W tungsten || Y || Y || Y || Y || Y || Y
+
|[[LS15]]||Bulb||15W tungsten||Y||Y||Y||Y||Y||Y
 
|-
 
|-
| [[TF]] || Power supply || Transformer || Y || Y || Y || Y || Y || Y
+
|[[TF]]||Power supply||Transformer||Y||Y||Y||Y||Y||Y
 
|-
 
|-
| [[M5X]] <br />[[M10X]] <br />[[M20X]] <br />[[M40X]] || Objective || Set || Y || Y || Y ||   ||   ||
+
|[[M5X]] <br />[[M10X]] <br />[[M20X]] <br />[[M40X]]||Objective||Set||Y||Y||Y|| || ||
 
|-
 
|-
| [[Neo5X]] <br />[[Neo10X]] <br />[[Neo20X]] <br />[[Neo40x]] || Objective || Set ||   ||   ||   || Y || Y || Y
+
|[[Neo5X]] <br />[[Neo10X]] <br />[[Neo20X]] <br />[[Neo40x]]||Objective||Set|| || || ||Y||Y||Y
 
|-
 
|-
|   || High eyepoint BiWF10X,paired eyepiece   ||   || Y || Y ||   || Y || Y
+
| ||High eyepoint BiWF10X,paired eyepiece|| ||Y||Y|| ||Y||Y
 
|-
 
|-
|   || High eyepoint WF10X eyepiece || Y ||   ||   || Y ||   ||
+
| ||High eyepoint WF10X eyepiece||Y|| || ||Y|| ||
 
|-
 
|-
| [[FK3.3X]] || Photo eyepiece ||   ||   || Y ||   ||   || Y
+
|[[FK3.3X]]||Photo eyepiece|| || ||Y|| || ||Y
 
|-
 
|-
|   || Stage plate || Y || Y || Y || Y || Y || Y
+
| ||Stage plate||Y||Y||Y||Y||Y||Y
 
|-
 
|-
|   || Stage clips || Y || Y || Y || Y || Y || Y
+
| ||Stage clips||Y||Y||Y||Y||Y||Y
 
|-
 
|-
|   || Eyepiece caps   ||   || Y || Y ||   || Y || Y
+
| ||Eyepiece caps|| ||Y||Y|| ||Y||Y
 
|-
 
|-
| [[32.5C]] || Blue filter || Y || Y || Y || Y || Y || Y
+
|[[32.5C]]||Blue filter||Y||Y||Y||Y||Y||Y
 
|-
 
|-
|   || Vinyl dust cover || Y || Y || Y || Y || Y || Y
+
| ||Vinyl dust cover||Y||Y||Y||Y||Y||Y
 
|-
 
|-
 
|}
 
|}
  
 +
= Measurements =
 +
Taken from Andrew Zonenberg's BHM unless otherwise stated.
 +
 +
=== Base plate ===
 +
Attaches to microscope frame with four M6x1.0 screws, 15mm long, in a 2x2 hole pattern. Base plate has 6.7mm clearance holes, scope body is tapped.
 +
 +
Back row: outside to outside 42.7 mm so center to center 36 mm
 +
 +
Front row: outside to outside 50.5 mm so center to center 43.8 mm
  
 +
Row spacing (diagonal): outside to outside 46.9 mm so center to center 40.2 mm.
  
 +
Screw heads are 9.9mm OD.
  
= References =
+
=References=
  
* Olympus Series BH System Microscope [BH microscope]: [http://www.alanwood.net/downloads/olympus-bh-bha-bhb-bhc-brochure.pdf]
+
*Olympus Series BH System Microscope [BH microscope]: [http://www.alanwood.net/downloads/olympus-bh-bha-bhb-bhc-brochure.pdf]
* Olympus metallurgical microscopes instruction manual, models BHMJ & BHMJ-N [instruction BHMJ/-N]: [http://www.alanwood.net/downloads/olympus-bhmj-bhmj-n-instructions.pdf]
+
*Olympus metallurgical microscopes instruction manual, models BHMJ & BHMJ-N [instruction BHMJ/-N]: [http://www.alanwood.net/downloads/olympus-bhmj-bhmj-n-instructions.pdf]

Revision as of 02:42, 5 September 2019


Part list

Model

TODO: add standard metallurgical

Image Name Description Notes
Olympus series bh microscope system1.jpg
Source: [BH microscope, cover] [[BHA]
Bottom illumination, removable nosepiece
BHB Bottom illumination, fixed nosepiece
BHC Bottom illumination, fixed nosepiece, integrated light source
BHMJ-02 Epi-illumination, sliding stanmd, BF, monocular
BHMJ-22 Epi-illumination, sliding stanmd, BF, binocular
Olympus bhmj and bhmj-n bhmj.png
Source: [instruction BHMJ/-N, 3] [[BHMJ-42]
Epi-illumination, sliding stanmd, BF, trinocular
BHMJ-02-N Epi-illumination, sliding stanmd, BF/DF, monocular
BHMJ-22-N Epi-illumination, sliding stanmd, BF/DF, binocular
BHMJ-42-N Epi-illumination, sliding stanmd, BF/DF, trinocular


Objective

M is BF only. Neo are BF/DF. All are M25 threaded

Image Part # Type Description Notes
M5X Objective 5x
M10X Objective 10x
M20X Objective 20x
M40X Objective 40x
Neo5X Objective 5x
Neo10X Objective 10x
Neo20X Objective 20x
Neo40X Objective 40x
BH-RE Nosepiece Quintuple
BH-RE Nosepiece
BH-NRE Nosepiece


Illuminator

Image Part # Type Description Notes
BH-MA Illuminator (vertical) Brightfield
BH-RLA Illuminator (vertical) Brightfield and darkfield
Olympus series bh microscope bh-lh.png
Source: [BH microscope, 9] [[BH-LH]
Lamphouse Tungsten, 30W Pre-centered
BH-LHM Lamphouse Tungsten
Olympus series bh microscope bh-lsh.png
Source: [BH microscope, 9] [[BH-LSH]
Lamphouse Halogen 100W Centerable
Olympus series bh microscope bh-lh.png
Source: [BH microscope, 9] [[BH-LH]
Lamphouse
Olympus series bh microscope ls30.png
Source: [BH microscope, 9] [[LS30]
Bulb 6V, 30W tungsten
Olympus series bh microscope ls15.png
Source: [BH microscope, 9] [[LS15]
Bulb 6V, 15W tungsten
FK5X Eyepiece, photo 5x
TF Power supply Transformer voltage range?
45C Filter for what?
Olympus series bh microscope jc12v 100w.png
Source: [BH microscope, 9] [[jc12v 100W]
Bulb Halogen


Observation tube

Image Part # Type Description Notes
CH-M045 Observation tube Monocular
Olympus series bh microscope bh-swtr.png
Source: [BH microscope, 11] [[BH-SWTR]
Observation tube Binocular w/ photo?
Olympus series bh microscope bh-bi30 bi45.png
Source: [BH microscope, 11] [[BH-BI30]
Observation tube Binocular, 30 degree
Olympus series bh microscope bh-bi30 bi45.png
Source: [BH microscope, 11] [[BH-BI45]
Observation tube Binocular, 45 degree
Olympus series bh microscope bh-tr30 tr45.png
Source: [BH microscope, 11] [[BH-TR30]
Observation tube Binocular, 30 degree (w/ photo)
Olympus series bh microscope bh-tr30 tr45.png
Source: [BH microscope, 11] [[BH-TR45]
Observation tube Binocular, 45 degree (w/ photo)
BiWF10X Eyepiece HEP, paired
Olympus series bh microscope emm-vi.png
Source: [BH microscope, 15] [[EMM-VI]
Olympus series bh microscope pm-10-35a.png
Source: [BH microscope, 15] [[PM-10-35A]
Olympus series bh microscope pm-10-35l2a.png
Source: [BH microscope, 15] [[PM-10-35L2A]
Olympus series bh microscope pm-10-35m.png
Source: [BH microscope, 15] [[PM-10-35M]
Olympus series bh microscope pm-6.png
Source: [BH microscope, 15] [[PM-6]


Misc

Image Part # Type Description Notes
Zoidberg bh neo turret.jpg [[BH-RE] Nosepiece Quintuple Neo objectives (M25)
Olympus series bh microscope bha-f.png
Source: [BH microscope, 9] [[BHA-F]
Stand Bottom illumination, removable nosepiece
Olympus series bh microscope bhb-f.png
Source: [BH microscope, 9] [[BHB-F]
Stand Bottom illumination, fixed nosepiece
Olympus series bh microscope bhc-f.png
Source: [BH microscope, 9] [[BHC-F]
Stand Bottom illumination, fixed nosepiece, integrated light Lowest cost?
Olympus series bh microscope bh-sv.png
Source: [BH microscope, 13] [[BH-SV]
Stage
Olympus series bh microscope bh-cd.png
Source: [BH microscope, 13] [[BH-CD]
Condenser Abbe
Olympus series bh microscope bh-aac.png
Source: [BH microscope, 13] [[BH-AAC]
Condenser Ach/Apla
BHMJ-ST, BHMJ-F Body/base
FK3.3X Photo eyepiece
32.5C Blue filter
Olympus series bh microscope ah-ca.png
Source: [BH microscope, 11] [[AH-CA]
Olympus series bh microscope ah-fa.png
Source: [BH microscope, 11] [[AH-FA]
Olympus series bh microscope bh-dcd.png
Source: [BH microscope, 13] [[BH-DCD]
Olympus series bh microscope bh-dcw.png
Source: [BH microscope, 13] [[BH-DCW]
Olympus series bh microscope bh-pc.png
Source: [BH microscope, 13] [[BH-PC]
Olympus series bh microscope bh-sh.png
Source: [BH microscope, 13] [[BH-SH]
Olympus series bh microscope bh-swc.png
Source: [BH microscope, 13] [[BH-SWC]


BHA/BHB/BHC configurations

Olympus series bh microscope system1.jpg

Above: probably a BHA. Source: [BH microscope, cover]

Source: [BH microscope, 18]

NOTE: -1, -2, etc are my notation for the color columns in [BH microscope, 18]

Part # Type Description BHA-1 BHA-2 BHA-3 BHA-4 BHB-1 BHB-2 BHB-3 BHB-4 BHC-1 BHC-2
BHA-F Stand Y Y Y Y
BHB-F Stand Y Y Y Y
BHC-F Stand Y Y
BH-RE Nosepiece Quintuple Y Y Y Y
BH-LH Lamphouse Y Y Y Y Y Y Y Y
LS30 Bulb 6V, 30W Y Y Y Y Y Y Y Y
LS15 Bulb 6V, 15W Y Y
BH-BI45 Observation tube 45 deg binocular Y Y Y Y Y
BH-TR45 Observation tube 45 deg trinocular Y Y Y Y Y
BH-SV Stage Y Y Y Y Y Y Y Y Y Y
BH-CD Condenser Abbe Y Y Y Y Y Y Y Y
BH-AAC Condenser Ach/Apla Y Y
Objective Achromat 4x, 10x, S-40x (spring), S-100x (spring, oil) set Y Y Y Y Y Y
Objective Plan achromat 4x, 10x, 40x (spring), 100x (spring, oil) set Y Y Y Y
Objective Plan achromat 20x (spring) Y Y
BiWF10X Eyepiece HEP, paired Y Y Y Y Y Y Y Y Y Y
FK5X Eyepiece, photo 5x Y Y Y Y Y
45C Filter for what?
Bulb Spare bulb (2x) Y Y Y Y Y Y Y Y Y Y
Fuse Spare fuse (2x) Y Y Y Y Y Y Y Y Y Y
Oil Immersion oil Y Y Y Y Y Y Y Y Y Y
Cover Vintyl dust cover Y Y Y Y Y Y Y Y Y Y


BHMJ configurations

Olympus bhmj and bhmj-n bhmj.png

Above: A BHMJ, probably a BHMJ-42. Source: [instruction BHMJ/-N, 3]

Source: [instruction BHMJ/-N, 2]

-N adds darkfield

Part # Type Description BHMJ-02 BHMJ-22 BHMJ-42 BHMJ-02-N BHMJ-22-N BHMJ-42-N
BHMJ-ST, BHMJ-F Body/base Y Y Y Y Y Y
BH-RE Nosepiece Y Y Y
BH-NRE Nosepiece Y Y Y
BH-MA Illuminator (vertical) Brightfield Y Y Y
BH-RLA Illuminator (vertical) Brightfield and darkfield Y Y Y
CH-M045 Observation tube Monocular Y Y
BH-BI45 Observation tube Monocular Y Y
BH-TR45 Observation tube Binocular (w/ photo) Y Y
BH-LHM Lamphouse Tungsten Y Y Y Y Y Y
LS15 Bulb 15W tungsten Y Y Y Y Y Y
TF Power supply Transformer Y Y Y Y Y Y
M5X
M10X
M20X
M40X
Objective Set Y Y Y
Neo5X
Neo10X
Neo20X
Neo40x
Objective Set Y Y Y
High eyepoint BiWF10X,paired eyepiece Y Y Y Y
High eyepoint WF10X eyepiece Y Y
FK3.3X Photo eyepiece Y Y
Stage plate Y Y Y Y Y Y
Stage clips Y Y Y Y Y Y
Eyepiece caps Y Y Y Y
32.5C Blue filter Y Y Y Y Y Y
Vinyl dust cover Y Y Y Y Y Y

Measurements

Taken from Andrew Zonenberg's BHM unless otherwise stated.

Base plate

Attaches to microscope frame with four M6x1.0 screws, 15mm long, in a 2x2 hole pattern. Base plate has 6.7mm clearance holes, scope body is tapped.

Back row: outside to outside 42.7 mm so center to center 36 mm

Front row: outside to outside 50.5 mm so center to center 43.8 mm

Row spacing (diagonal): outside to outside 46.9 mm so center to center 40.2 mm.

Screw heads are 9.9mm OD.

References

  • Olympus Series BH System Microscope [BH microscope]: [1]
  • Olympus metallurgical microscopes instruction manual, models BHMJ & BHMJ-N [instruction BHMJ/-N]: [2]