Difference between revisions of "Olympus BH"
Line 8: | Line 8: | ||
{| class="wikitable sortable" border=1 | {| class="wikitable sortable" border=1 | ||
− | ! Image !! Name !! Description !! Notes | + | ! Image !! Name !! Description !! Notes |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_system1.jpg|300 px]] <br />Source: [BH microscope, cover] [[BHA] || Bottom illumination, removable nosepiece || |
|- | |- | ||
− | | || [[BHB]] || Bottom illumination, fixed nosepiece || | + | | || [[BHB]] || Bottom illumination, fixed nosepiece || |
|- | |- | ||
− | | || [[BHC]] || Bottom illumination, fixed nosepiece, integrated light source || | + | | || [[BHC]] || Bottom illumination, fixed nosepiece, integrated light source || |
|- | |- | ||
− | | || [[BHMJ-02]] || Epi-illumination, sliding stanmd, BF, monocular || | + | | || [[BHMJ-02]] || Epi-illumination, sliding stanmd, BF, monocular || |
|- | |- | ||
− | | || [[BHMJ-22]] || Epi-illumination, sliding stanmd, BF, binocular || | + | | || [[BHMJ-22]] || Epi-illumination, sliding stanmd, BF, binocular || |
|- | |- | ||
− | | | + | | [[File:olympus_bhmj_and_bhmj-n_bhmj.png|300 px]] <br />Source: [instruction BHMJ/-N, 3] [[BHMJ-42] || || Epi-illumination, sliding stanmd, BF, trinocular || |
|- | |- | ||
− | | || [[BHMJ-02-N]] || Epi-illumination, sliding stanmd, BF/DF, monocular || | + | | || [[BHMJ-02-N]] || Epi-illumination, sliding stanmd, BF/DF, monocular || |
|- | |- | ||
− | | || [[BHMJ-22-N]] || Epi-illumination, sliding stanmd, BF/DF, binocular || | + | | || [[BHMJ-22-N]] || Epi-illumination, sliding stanmd, BF/DF, binocular || |
|- | |- | ||
− | | || [[BHMJ-42-N]] || Epi-illumination, sliding stanmd, BF/DF, trinocular || | + | | || [[BHMJ-42-N]] || Epi-illumination, sliding stanmd, BF/DF, trinocular || |
|- | |- | ||
|} | |} | ||
Line 36: | Line 36: | ||
{| class="wikitable sortable" border=1 | {| class="wikitable sortable" border=1 | ||
− | ! Image !! Part # !! Type !! Description !! Notes | + | ! Image !! Part # !! Type !! Description !! Notes |
|- | |- | ||
− | | || [[M5X]] || Objective || 5x || | + | | || [[M5X]] || Objective || 5x || |
|- | |- | ||
− | | || [[M10X]] || Objective || 10x || | + | | || [[M10X]] || Objective || 10x || |
|- | |- | ||
− | | || [[M20X]] || Objective || 20x || | + | | || [[M20X]] || Objective || 20x || |
|- | |- | ||
− | | || [[M40X]] || Objective || 40x || | + | | || [[M40X]] || Objective || 40x || |
|- | |- | ||
− | | || [[Neo5X]] || Objective || 5x || | + | | || [[Neo5X]] || Objective || 5x || |
|- | |- | ||
− | | || [[Neo10X]] || Objective || 10x || | + | | || [[Neo10X]] || Objective || 10x || |
|- | |- | ||
− | | || [[Neo20X]] || Objective || 20x || | + | | || [[Neo20X]] || Objective || 20x || |
|- | |- | ||
− | | || [[Neo40X]] || Objective || 40x || | + | | || [[Neo40X]] || Objective || 40x || |
|- | |- | ||
− | | || [[BH-RE]] || Nosepiece || Quintuple || | + | | || [[BH-RE]] || Nosepiece || Quintuple || |
|- | |- | ||
− | | || [[BH-RE]] || Nosepiece || || | + | | || [[BH-RE]] || Nosepiece || || |
|- | |- | ||
− | | || [[BH-NRE]] || Nosepiece || || | + | | || [[BH-NRE]] || Nosepiece || || |
|- | |- | ||
|} | |} | ||
Line 66: | Line 66: | ||
{| class="wikitable sortable" border=1 | {| class="wikitable sortable" border=1 | ||
− | ! Image !! Part # !! Type !! Description !! Notes | + | ! Image !! Part # !! Type !! Description !! Notes |
|- | |- | ||
− | | || [[BH-MA]] || Illuminator (vertical) || Brightfield || | + | | || [[BH-MA]] || Illuminator (vertical) || Brightfield || |
|- | |- | ||
− | | || [[BH-RLA]] || Illuminator (vertical) || Brightfield and darkfield || | + | | || [[BH-RLA]] || Illuminator (vertical) || Brightfield and darkfield || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bh-lh.png|300 px]] <br />Source: [BH microscope, 9] [[BH-LH] || Lamphouse || Tungsten, 30W || Pre-centered |
|- | |- | ||
− | | || [[BH-LHM]] || Lamphouse || Tungsten || | + | | || [[BH-LHM]] || Lamphouse || Tungsten || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bh-lsh.png|300 px]] <br />Source: [BH microscope, 9] [[BH-LSH] || Lamphouse || Halogen 100W || Centerable |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bh-lh.png|300 px]] <br />Source: [BH microscope, 9] [[BH-LH] || Lamphouse || || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_ls30.png|100 px]] <br />Source: [BH microscope, 9] [[LS30] || Bulb || 6V, 30W tungsten || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_ls15.png|100 px]] <br />Source: [BH microscope, 9] [[LS15] || Bulb || 6V, 15W tungsten || |
|- | |- | ||
− | | || [[FK5X]] || Eyepiece, photo || 5x || | + | | || [[FK5X]] || Eyepiece, photo || 5x || |
|- | |- | ||
− | | || [[TF]] || Power supply || Transformer || voltage range? | + | | || [[TF]] || Power supply || Transformer || voltage range? |
|- | |- | ||
− | | || [[45C]] || Filter || for what? || | + | | || [[45C]] || Filter || for what? || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_jc12v_100w.png|150 px]] <br />Source: [BH microscope, 9] [[jc12v 100W] || Bulb || Halogen || |
|- | |- | ||
|} | |} | ||
Line 98: | Line 98: | ||
{| class="wikitable sortable" border=1 | {| class="wikitable sortable" border=1 | ||
− | ! Image !! Part # !! Type !! Description !! Notes | + | ! Image !! Part # !! Type !! Description !! Notes |
|- | |- | ||
− | | || [[CH-M045]] || Observation tube || Monocular || | + | | || [[CH-M045]] || Observation tube || Monocular || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bh-swtr.png|300 px]] <br />Source: [BH microscope, 11] [[BH-SWTR] || Observation tube || Binocular w/ photo? || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bh-bi30_bi45.png|300 px]] <br />Source: [BH microscope, 11] [[BH-BI30] || Observation tube || Binocular, 30 degree || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bh-bi30_bi45.png|300 px]] <br />Source: [BH microscope, 11] [[BH-BI45] || Observation tube || Binocular, 45 degree || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bh-tr30_tr45.png|300 px]] <br />Source: [BH microscope, 11] [[BH-TR30] || Observation tube || Binocular, 30 degree (w/ photo) || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bh-tr30_tr45.png|300 px]] <br />Source: [BH microscope, 11] [[BH-TR45] || Observation tube || Binocular, 45 degree (w/ photo) || |
|- | |- | ||
− | | || [[BiWF10X]] || Eyepiece || HEP, paired || | + | | || [[BiWF10X]] || Eyepiece || HEP, paired || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_emm-vi.png|300 px]] <br />Source: [BH microscope, 15] [[EMM-VI] || || || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_pm-10-35a.png|300 px]] <br />Source: [BH microscope, 15] [[PM-10-35A] || || || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_pm-10-35l2a.png|300 px]] <br />Source: [BH microscope, 15] [[PM-10-35L2A] || || || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_pm-10-35m.png|300 px]] <br />Source: [BH microscope, 15] [[PM-10-35M] || || || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_pm-6.png|300 px]] <br />Source: [BH microscope, 15] [[PM-6] || || || |
|- | |- | ||
|} | |} | ||
Line 130: | Line 130: | ||
{| class="wikitable sortable" border=1 | {| class="wikitable sortable" border=1 | ||
− | ! Image !! Part # !! Type !! Description !! Notes | + | ! Image !! Part # !! Type !! Description !! Notes |
|- | |- | ||
− | | | + | | [[File:zoidberg_bh_neo_turret.jpg|200 px]] [[BH-RE] || Nosepiece || Quintuple || Neo objectives (M25) |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bha-f.png|300 px]] <br />Source: [BH microscope, 9] [[BHA-F] || Stand || Bottom illumination, removable nosepiece || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bhb-f.png|300 px]] <br />Source: [BH microscope, 9] [[BHB-F] || Stand || Bottom illumination, fixed nosepiece || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bhc-f.png|300 px]] <br />Source: [BH microscope, 9] [[BHC-F] || Stand || Bottom illumination, fixed nosepiece, integrated light || Lowest cost? |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bh-sv.png|300 px]] <br />Source: [BH microscope, 13] [[BH-SV] || Stage || || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bh-cd.png|300 px]] <br />Source: [BH microscope, 13] [[BH-CD] || Condenser || Abbe || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bh-aac.png|300 px]] <br />Source: [BH microscope, 13] [[BH-AAC] || Condenser || Ach/Apla || |
|- | |- | ||
− | | || [[BHMJ-ST]], [[BHMJ-F]] || Body/base || | + | | || [[BHMJ-ST]], [[BHMJ-F]] || Body/base || |
|- | |- | ||
− | | || [[FK3.3X]] || Photo eyepiece || || | + | | || [[FK3.3X]] || Photo eyepiece || || |
|- | |- | ||
− | | || [[32.5C]] || Blue filter || | + | | || [[32.5C]] || Blue filter || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_ah-ca.png|300 px]] <br />Source: [BH microscope, 11] [[AH-CA] || || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_ah-fa.png|300 px]] <br />Source: [BH microscope, 11] [[AH-FA] || || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bh-dcd.png|300 px]] <br />Source: [BH microscope, 13] [[BH-DCD] || || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bh-dcw.png|300 px]] <br />Source: [BH microscope, 13] [[BH-DCW] || || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bh-pc.png|300 px]] <br />Source: [BH microscope, 13] [[BH-PC] || || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bh-sh.png|300 px]] <br />Source: [BH microscope, 13] [[BH-SH] || || |
|- | |- | ||
− | | | + | | [[File:olympus_series_bh_microscope_bh-swc.png|300 px]] <br />Source: [BH microscope, 13] [[BH-SWC] || || |
|- | |- | ||
|} | |} | ||
Line 172: | Line 172: | ||
= BHA/BHB/BHC configurations = | = BHA/BHB/BHC configurations = | ||
− | + | [[File:olympus_series_bh_microscope_system1.jpg|300 px]] | |
Above: probably a BHA. Source: [BH microscope, cover] | Above: probably a BHA. Source: [BH microscope, cover] | ||
Line 181: | Line 181: | ||
{| class="wikitable sortable" border=1 | {| class="wikitable sortable" border=1 | ||
− | ! Part # !! Type !! Description !! BHA-1 !! BHA-2 !! BHA-3 !! BHA-4 !! BHB-1 !! BHB-2 !! BHB-3 !! BHB-4 !! BHC-1 !! BHC-2 | + | ! Part # !! Type !! Description !! BHA-1 !! BHA-2 !! BHA-3 !! BHA-4 !! BHB-1 !! BHB-2 !! BHB-3 !! BHB-4 !! BHC-1 !! BHC-2 |
|- | |- | ||
− | | [[BHA-F]] || Stand || || Y || Y || Y || Y || || || || || || | + | | [[BHA-F]] || Stand || || Y || Y || Y || Y || || || || || || |
|- | |- | ||
− | | [[BHB-F]] || Stand || || || || || || Y || Y || Y || Y || || | + | | [[BHB-F]] || Stand || || || || || || Y || Y || Y || Y || || |
|- | |- | ||
− | | [[BHC-F]] || Stand || || || || || || || || || || Y || Y | + | | [[BHC-F]] || Stand || || || || || || || || || || Y || Y |
|- | |- | ||
− | | [[BH-RE]] || Nosepiece || Quintuple || Y || Y || Y || Y || || || || || || | + | | [[BH-RE]] || Nosepiece || Quintuple || Y || Y || Y || Y || || || || || || |
|- | |- | ||
− | | [[BH-LH]] || Lamphouse || || Y || Y || Y || Y || Y || Y || Y || Y || || | + | | [[BH-LH]] || Lamphouse || || Y || Y || Y || Y || Y || Y || Y || Y || || |
|- | |- | ||
− | | [[LS30]] || Bulb || 6V, 30W || Y || Y || Y || Y || Y || Y || Y || Y || || | + | | [[LS30]] || Bulb || 6V, 30W || Y || Y || Y || Y || Y || Y || Y || Y || || |
|- | |- | ||
− | | [[LS15]] || Bulb || 6V, 15W || || || || || || || || || Y || Y | + | | [[LS15]] || Bulb || 6V, 15W || || || || || || || || || Y || Y |
|- | |- | ||
− | | [[BH-BI45]] || Observation tube || 45 deg binocular || || Y || || Y || || Y || || Y || || Y | + | | [[BH-BI45]] || Observation tube || 45 deg binocular || || Y || || Y || || Y || || Y || || Y |
|- | |- | ||
− | | [[BH-TR45]] || Observation tube || 45 deg trinocular || Y || || Y || || Y || || Y || || Y || | + | | [[BH-TR45]] || Observation tube || 45 deg trinocular || Y || || Y || || Y || || Y || || Y || |
|- | |- | ||
− | | [[BH-SV]] || Stage || || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y | + | | [[BH-SV]] || Stage || || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y |
|- | |- | ||
− | | [[BH-CD]] || Condenser || Abbe || || || Y || Y || Y || Y || Y || Y || Y || Y | + | | [[BH-CD]] || Condenser || Abbe || || || Y || Y || Y || Y || Y || Y || Y || Y |
|- | |- | ||
− | | [[BH-AAC]] || Condenser || Ach/Apla || Y || Y || || || || || || || || | + | | [[BH-AAC]] || Condenser || Ach/Apla || Y || Y || || || || || || || || |
|- | |- | ||
− | | || Objective || Achromat 4x, 10x, S-40x (spring), S-100x (spring, oil) set || || || Y || Y || || || Y || Y || Y || Y | + | | || Objective || Achromat 4x, 10x, S-40x (spring), S-100x (spring, oil) set || || || Y || Y || || || Y || Y || Y || Y |
|- | |- | ||
− | | || Objective || Plan achromat 4x, 10x, 40x (spring), 100x (spring, oil) set || Y || Y || || || Y || Y || || || || | + | | || Objective || Plan achromat 4x, 10x, 40x (spring), 100x (spring, oil) set || Y || Y || || || Y || Y || || || || |
|- | |- | ||
− | | || Objective || Plan achromat 20x (spring) || Y || Y || || || || || || || || | + | | || Objective || Plan achromat 20x (spring) || Y || Y || || || || || || || || |
|- | |- | ||
− | | [[BiWF10X]] || Eyepiece || HEP, paired || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y | + | | [[BiWF10X]] || Eyepiece || HEP, paired || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y |
|- | |- | ||
− | | [[FK5X]] || Eyepiece, photo || 5x || Y || || Y || || Y || || Y || || Y || | + | | [[FK5X]] || Eyepiece, photo || 5x || Y || || Y || || Y || || Y || || Y || |
|- | |- | ||
− | | [[45C]] || Filter || for what? || || || || || || || || || || | + | | [[45C]] || Filter || for what? || || || || || || || || || || |
|- | |- | ||
− | | || Bulb || Spare bulb (2x) || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y | + | | || Bulb || Spare bulb (2x) || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y |
|- | |- | ||
− | | || Fuse || Spare fuse (2x) || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y | + | | || Fuse || Spare fuse (2x) || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y |
|- | |- | ||
− | | || Oil || Immersion oil || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y | + | | || Oil || Immersion oil || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y |
|- | |- | ||
− | | || Cover || Vintyl dust cover || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y | + | | || Cover || Vintyl dust cover || Y || Y || Y || Y || Y || Y || Y || Y || Y || Y |
|- | |- | ||
|} | |} | ||
Line 232: | Line 232: | ||
= BHMJ configurations = | = BHMJ configurations = | ||
− | + | [[File:olympus_bhmj_and_bhmj-n_bhmj.png|300 px]] | |
Above: A BHMJ, probably a BHMJ-42. Source: [instruction BHMJ/-N, 3] | Above: A BHMJ, probably a BHMJ-42. Source: [instruction BHMJ/-N, 3] | ||
Line 241: | Line 241: | ||
{| class="wikitable sortable" border=1 | {| class="wikitable sortable" border=1 | ||
− | ! Part # !! Type !! Description !! BHMJ-02 !! BHMJ-22 !! BHMJ-42 !! BHMJ-02-N !! BHMJ-22-N !! BHMJ-42-N | + | ! Part # !! Type !! Description !! BHMJ-02 !! BHMJ-22 !! BHMJ-42 !! BHMJ-02-N !! BHMJ-22-N !! BHMJ-42-N |
|- | |- | ||
− | | [[BHMJ-ST]], [[BHMJ-F]] || Body/base || || Y || Y || Y || Y || Y || Y | + | | [[BHMJ-ST]], [[BHMJ-F]] || Body/base || || Y || Y || Y || Y || Y || Y |
|- | |- | ||
− | | [[BH-RE]] || Nosepiece || || Y || Y || Y || || || | + | | [[BH-RE]] || Nosepiece || || Y || Y || Y || || || |
|- | |- | ||
− | | [[BH-NRE]] || Nosepiece || || || || || Y || Y || Y | + | | [[BH-NRE]] || Nosepiece || || || || || Y || Y || Y |
|- | |- | ||
− | | [[BH-MA]] || Illuminator (vertical) || Brightfield || Y || Y || Y || || || | + | | [[BH-MA]] || Illuminator (vertical) || Brightfield || Y || Y || Y || || || |
|- | |- | ||
− | | [[BH-RLA]] || Illuminator (vertical) || Brightfield and darkfield || || || || Y || Y || Y | + | | [[BH-RLA]] || Illuminator (vertical) || Brightfield and darkfield || || || || Y || Y || Y |
|- | |- | ||
− | | [[CH-M045]] || Observation tube || Monocular || Y || || || Y || || | + | | [[CH-M045]] || Observation tube || Monocular || Y || || || Y || || |
|- | |- | ||
− | | [[BH-BI45]] || Observation tube || Monocular || || Y || || || Y || | + | | [[BH-BI45]] || Observation tube || Monocular || || Y || || || Y || |
|- | |- | ||
− | | [[BH-TR45]] || Observation tube || Binocular (w/ photo) || || || Y || || || Y | + | | [[BH-TR45]] || Observation tube || Binocular (w/ photo) || || || Y || || || Y |
|- | |- | ||
− | | [[BH-LHM]] || Lamphouse || Tungsten || Y || Y || Y || Y || Y || Y | + | | [[BH-LHM]] || Lamphouse || Tungsten || Y || Y || Y || Y || Y || Y |
|- | |- | ||
− | | [[LS15]] || Bulb || 15W tungsten || Y || Y || Y || Y || Y || Y | + | | [[LS15]] || Bulb || 15W tungsten || Y || Y || Y || Y || Y || Y |
|- | |- | ||
− | | [[TF]] || Power supply || Transformer || Y || Y || Y || Y || Y || Y | + | | [[TF]] || Power supply || Transformer || Y || Y || Y || Y || Y || Y |
|- | |- | ||
− | | [[M5X]] <br />[[M10X]] <br />[[M20X]] <br />[[M40X]] || Objective || Set || Y || Y || Y || || || | + | | [[M5X]] <br />[[M10X]] <br />[[M20X]] <br />[[M40X]] || Objective || Set || Y || Y || Y || || || |
|- | |- | ||
− | | [[Neo5X]] <br />[[Neo10X]] <br />[[Neo20X]] <br />[[Neo40x]] || Objective || Set || || || || Y || Y || Y | + | | [[Neo5X]] <br />[[Neo10X]] <br />[[Neo20X]] <br />[[Neo40x]] || Objective || Set || || || || Y || Y || Y |
|- | |- | ||
− | | || High eyepoint BiWF10X,paired eyepiece || || Y || Y || || Y || Y | + | | || High eyepoint BiWF10X,paired eyepiece || || Y || Y || || Y || Y |
|- | |- | ||
− | | || High eyepoint WF10X eyepiece || Y || || || Y || || | + | | || High eyepoint WF10X eyepiece || Y || || || Y || || |
|- | |- | ||
− | | [[FK3.3X]] || Photo eyepiece || || || Y || || || Y | + | | [[FK3.3X]] || Photo eyepiece || || || Y || || || Y |
|- | |- | ||
− | | || Stage plate || Y || Y || Y || Y || Y || Y | + | | || Stage plate || Y || Y || Y || Y || Y || Y |
|- | |- | ||
− | | || Stage clips || Y || Y || Y || Y || Y || Y | + | | || Stage clips || Y || Y || Y || Y || Y || Y |
|- | |- | ||
− | | || Eyepiece caps || || Y || Y || || Y || Y | + | | || Eyepiece caps || || Y || Y || || Y || Y |
|- | |- | ||
− | | [[32.5C]] || Blue filter || Y || Y || Y || Y || Y || Y | + | | [[32.5C]] || Blue filter || Y || Y || Y || Y || Y || Y |
|- | |- | ||
− | | || Vinyl dust cover || Y || Y || Y || Y || Y || Y | + | | || Vinyl dust cover || Y || Y || Y || Y || Y || Y |
|- | |- | ||
|} | |} | ||
Line 292: | Line 292: | ||
= References = | = References = | ||
− | * Olympus Series BH System Microscope [BH microscope]: http: | + | * Olympus Series BH System Microscope [BH microscope]: [http://www.alanwood.net/downloads/olympus-bh-bha-bhb-bhc-brochure.pdf] |
− | * Olympus metallurgical microscopes instruction manual, models BHMJ & BHMJ-N [instruction BHMJ/-N]: http: | + | * Olympus metallurgical microscopes instruction manual, models BHMJ & BHMJ-N [instruction BHMJ/-N]: [http://www.alanwood.net/downloads/olympus-bhmj-bhmj-n-instructions.pdf] |
Revision as of 11:47, 26 December 2018
Contents
Part list
Model
TODO: add standard metallurgical
Image | Name | Description | Notes |
---|---|---|---|
Source: [BH microscope, cover] [[BHA] |
Bottom illumination, removable nosepiece | ||
BHB | Bottom illumination, fixed nosepiece | ||
BHC | Bottom illumination, fixed nosepiece, integrated light source | ||
BHMJ-02 | Epi-illumination, sliding stanmd, BF, monocular | ||
BHMJ-22 | Epi-illumination, sliding stanmd, BF, binocular | ||
Source: [instruction BHMJ/-N, 3] [[BHMJ-42] |
Epi-illumination, sliding stanmd, BF, trinocular | ||
BHMJ-02-N | Epi-illumination, sliding stanmd, BF/DF, monocular | ||
BHMJ-22-N | Epi-illumination, sliding stanmd, BF/DF, binocular | ||
BHMJ-42-N | Epi-illumination, sliding stanmd, BF/DF, trinocular |
Objective
M is BF only. Neo are BF/DF. All are M25 threaded
Image | Part # | Type | Description | Notes |
---|---|---|---|---|
M5X | Objective | 5x | ||
M10X | Objective | 10x | ||
M20X | Objective | 20x | ||
M40X | Objective | 40x | ||
Neo5X | Objective | 5x | ||
Neo10X | Objective | 10x | ||
Neo20X | Objective | 20x | ||
Neo40X | Objective | 40x | ||
BH-RE | Nosepiece | Quintuple | ||
BH-RE | Nosepiece | |||
BH-NRE | Nosepiece |
Illuminator
Image | Part # | Type | Description | Notes |
---|---|---|---|---|
BH-MA | Illuminator (vertical) | Brightfield | ||
BH-RLA | Illuminator (vertical) | Brightfield and darkfield | ||
Source: [BH microscope, 9] [[BH-LH] |
Lamphouse | Tungsten, 30W | Pre-centered | |
BH-LHM | Lamphouse | Tungsten | ||
Source: [BH microscope, 9] [[BH-LSH] |
Lamphouse | Halogen 100W | Centerable | |
Source: [BH microscope, 9] [[BH-LH] |
Lamphouse | |||
Source: [BH microscope, 9] [[LS30] |
Bulb | 6V, 30W tungsten | ||
Source: [BH microscope, 9] [[LS15] |
Bulb | 6V, 15W tungsten | ||
FK5X | Eyepiece, photo | 5x | ||
TF | Power supply | Transformer | voltage range? | |
45C | Filter | for what? | ||
Source: [BH microscope, 9] [[jc12v 100W] |
Bulb | Halogen |
Observation tube
Image | Part # | Type | Description | Notes |
---|---|---|---|---|
CH-M045 | Observation tube | Monocular | ||
Source: [BH microscope, 11] [[BH-SWTR] |
Observation tube | Binocular w/ photo? | ||
Source: [BH microscope, 11] [[BH-BI30] |
Observation tube | Binocular, 30 degree | ||
Source: [BH microscope, 11] [[BH-BI45] |
Observation tube | Binocular, 45 degree | ||
Source: [BH microscope, 11] [[BH-TR30] |
Observation tube | Binocular, 30 degree (w/ photo) | ||
Source: [BH microscope, 11] [[BH-TR45] |
Observation tube | Binocular, 45 degree (w/ photo) | ||
BiWF10X | Eyepiece | HEP, paired | ||
Source: [BH microscope, 15] [[EMM-VI] |
||||
Source: [BH microscope, 15] [[PM-10-35A] |
||||
Source: [BH microscope, 15] [[PM-10-35L2A] |
||||
Source: [BH microscope, 15] [[PM-10-35M] |
||||
Source: [BH microscope, 15] [[PM-6] |
Misc
Image | Part # | Type | Description | Notes |
---|---|---|---|---|
[[BH-RE] | Nosepiece | Quintuple | Neo objectives (M25) | |
Source: [BH microscope, 9] [[BHA-F] |
Stand | Bottom illumination, removable nosepiece | ||
Source: [BH microscope, 9] [[BHB-F] |
Stand | Bottom illumination, fixed nosepiece | ||
Source: [BH microscope, 9] [[BHC-F] |
Stand | Bottom illumination, fixed nosepiece, integrated light | Lowest cost? | |
Source: [BH microscope, 13] [[BH-SV] |
Stage | |||
Source: [BH microscope, 13] [[BH-CD] |
Condenser | Abbe | ||
Source: [BH microscope, 13] [[BH-AAC] |
Condenser | Ach/Apla | ||
BHMJ-ST, BHMJ-F | Body/base | |||
FK3.3X | Photo eyepiece | |||
32.5C | Blue filter | |||
Source: [BH microscope, 11] [[AH-CA] |
||||
Source: [BH microscope, 11] [[AH-FA] |
||||
Source: [BH microscope, 13] [[BH-DCD] |
||||
Source: [BH microscope, 13] [[BH-DCW] |
||||
Source: [BH microscope, 13] [[BH-PC] |
||||
Source: [BH microscope, 13] [[BH-SH] |
||||
Source: [BH microscope, 13] [[BH-SWC] |
BHA/BHB/BHC configurations
Above: probably a BHA. Source: [BH microscope, cover]
Source: [BH microscope, 18]
NOTE: -1, -2, etc are my notation for the color columns in [BH microscope, 18]
Part # | Type | Description | BHA-1 | BHA-2 | BHA-3 | BHA-4 | BHB-1 | BHB-2 | BHB-3 | BHB-4 | BHC-1 | BHC-2 |
---|---|---|---|---|---|---|---|---|---|---|---|---|
BHA-F | Stand | Y | Y | Y | Y | |||||||
BHB-F | Stand | Y | Y | Y | Y | |||||||
BHC-F | Stand | Y | Y | |||||||||
BH-RE | Nosepiece | Quintuple | Y | Y | Y | Y | ||||||
BH-LH | Lamphouse | Y | Y | Y | Y | Y | Y | Y | Y | |||
LS30 | Bulb | 6V, 30W | Y | Y | Y | Y | Y | Y | Y | Y | ||
LS15 | Bulb | 6V, 15W | Y | Y | ||||||||
BH-BI45 | Observation tube | 45 deg binocular | Y | Y | Y | Y | Y | |||||
BH-TR45 | Observation tube | 45 deg trinocular | Y | Y | Y | Y | Y | |||||
BH-SV | Stage | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | |
BH-CD | Condenser | Abbe | Y | Y | Y | Y | Y | Y | Y | Y | ||
BH-AAC | Condenser | Ach/Apla | Y | Y | ||||||||
Objective | Achromat 4x, 10x, S-40x (spring), S-100x (spring, oil) set | Y | Y | Y | Y | Y | Y | |||||
Objective | Plan achromat 4x, 10x, 40x (spring), 100x (spring, oil) set | Y | Y | Y | Y | |||||||
Objective | Plan achromat 20x (spring) | Y | Y | |||||||||
BiWF10X | Eyepiece | HEP, paired | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
FK5X | Eyepiece, photo | 5x | Y | Y | Y | Y | Y | |||||
45C | Filter | for what? | ||||||||||
Bulb | Spare bulb (2x) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | |
Fuse | Spare fuse (2x) | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | |
Oil | Immersion oil | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | |
Cover | Vintyl dust cover | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
BHMJ configurations
Above: A BHMJ, probably a BHMJ-42. Source: [instruction BHMJ/-N, 3]
Source: [instruction BHMJ/-N, 2]
-N adds darkfield
Part # | Type | Description | BHMJ-02 | BHMJ-22 | BHMJ-42 | BHMJ-02-N | BHMJ-22-N | BHMJ-42-N |
---|---|---|---|---|---|---|---|---|
BHMJ-ST, BHMJ-F | Body/base | Y | Y | Y | Y | Y | Y | |
BH-RE | Nosepiece | Y | Y | Y | ||||
BH-NRE | Nosepiece | Y | Y | Y | ||||
BH-MA | Illuminator (vertical) | Brightfield | Y | Y | Y | |||
BH-RLA | Illuminator (vertical) | Brightfield and darkfield | Y | Y | Y | |||
CH-M045 | Observation tube | Monocular | Y | Y | ||||
BH-BI45 | Observation tube | Monocular | Y | Y | ||||
BH-TR45 | Observation tube | Binocular (w/ photo) | Y | Y | ||||
BH-LHM | Lamphouse | Tungsten | Y | Y | Y | Y | Y | Y |
LS15 | Bulb | 15W tungsten | Y | Y | Y | Y | Y | Y |
TF | Power supply | Transformer | Y | Y | Y | Y | Y | Y |
M5X M10X M20X M40X |
Objective | Set | Y | Y | Y | |||
Neo5X Neo10X Neo20X Neo40x |
Objective | Set | Y | Y | Y | |||
High eyepoint BiWF10X,paired eyepiece | Y | Y | Y | Y | ||||
High eyepoint WF10X eyepiece | Y | Y | ||||||
FK3.3X | Photo eyepiece | Y | Y | |||||
Stage plate | Y | Y | Y | Y | Y | Y | ||
Stage clips | Y | Y | Y | Y | Y | Y | ||
Eyepiece caps | Y | Y | Y | Y | ||||
32.5C | Blue filter | Y | Y | Y | Y | Y | Y | |
Vinyl dust cover | Y | Y | Y | Y | Y | Y |