Difference between revisions of "Molectron"
(Created page with "Information on Molectron / coherent laser power meters. Ultimately for the ezlaze project Old power supply") |
|||
Line 2: | Line 2: | ||
− | + | ||
+ | |||
+ | = JD1000 = | ||
+ | |||
+ | Power supply: CS-1203000 (12V @ 3A, center positive) | ||
+ | |||
+ | = McMaster = | ||
+ | |||
+ | McMaster inventory: | ||
+ | * Meter | ||
+ | ** 3Sigma (nice screen) | ||
+ | ** 3Sigma (messy screen) | ||
+ | ** JD1000: broken, trashing | ||
+ | *** Capacitor exploded when plugged in. After that didn't seem to really work | ||
+ | * Sensor | ||
+ | ** J25LP | ||
+ | |||
+ | == J25LP == | ||
+ | |||
+ | Came with JD1000. No 25 pin adapter | ||
+ | |||
+ | Back: | ||
+ | MODEL NO: J25LP | ||
+ | SERIAL NO: 238 | ||
+ | |||
+ | RESPONSITIVITY | ||
+ | 5.10 VOLT/JOULE | ||
+ | 337.1 nm | ||
+ | |||
+ | == 3Sigma (eBay) sensor == | ||
+ | |||
+ | 3Sigma output: | ||
+ | Probe Resp: 2.570E-1 A/W @ 514 nm | ||
+ | Probe Cal Date Sep 10 2003 | ||
+ | Wavelenth Corr 1064 nm / On | ||
+ | Attenuation Corr: 1.00E0 / Off | ||
+ | Area Corr 1.0000 sq cm / Off | ||
+ | |||
+ | DB25 label: | ||
+ | FIXME | ||
+ | |||
+ | Sensor label: | ||
+ | FIXME | ||
+ | |||
+ | == J-25MB-HE sensor == | ||
+ | |||
+ | 3Sigma output: | ||
+ | FIXME | ||
+ | |||
+ | Cable label: | ||
+ | COHERENT | ||
+ | Item# 1110748 | ||
+ | Model: J-25MB-HE | ||
+ | Serial#: 0984E07R | ||
+ | |||
+ | Responsitivity | ||
+ | 6.694e + 0 V/J | ||
+ | Cal 1064 nm | ||
+ | |||
+ | == 3Sigma (eBay) meter == | ||
+ | |||
+ | Came with CW sensor | ||
+ | |||
+ | == 3Sigma (dumpster dive) meter == | ||
+ | |||
+ | Came w/ sensor + BNC adapter | ||
+ | |||
+ | Screen is messed up | ||
+ | |||
+ | Came with Lemo cable. Doesn't fit trigger ports or anything I can tell |
Revision as of 00:20, 27 October 2021
Information on Molectron / coherent laser power meters. Ultimately for the ezlaze project
Contents
JD1000
Power supply: CS-1203000 (12V @ 3A, center positive)
McMaster
McMaster inventory:
- Meter
- 3Sigma (nice screen)
- 3Sigma (messy screen)
- JD1000: broken, trashing
- Capacitor exploded when plugged in. After that didn't seem to really work
- Sensor
- J25LP
J25LP
Came with JD1000. No 25 pin adapter
Back:
MODEL NO: J25LP SERIAL NO: 238 RESPONSITIVITY 5.10 VOLT/JOULE 337.1 nm
3Sigma (eBay) sensor
3Sigma output:
Probe Resp: 2.570E-1 A/W @ 514 nm Probe Cal Date Sep 10 2003 Wavelenth Corr 1064 nm / On Attenuation Corr: 1.00E0 / Off Area Corr 1.0000 sq cm / Off
DB25 label:
FIXME
Sensor label:
FIXME
J-25MB-HE sensor
3Sigma output:
FIXME
Cable label:
COHERENT Item# 1110748 Model: J-25MB-HE Serial#: 0984E07R
Responsitivity 6.694e + 0 V/J Cal 1064 nm
3Sigma (eBay) meter
Came with CW sensor
3Sigma (dumpster dive) meter
Came w/ sensor + BNC adapter
Screen is messed up
Came with Lemo cable. Doesn't fit trigger ports or anything I can tell