Difference between revisions of "Infrared"
(Tag: Visual edit) |
(Tag: Visual edit) |
||
Line 10: | Line 10: | ||
|- | |- | ||
|InGaAs | |InGaAs | ||
− | |0.9 | + | |0.9 - 1.7 |
| | | | ||
|SUI goodrich SU320KTSW | |SUI goodrich SU320KTSW | ||
Line 16: | Line 16: | ||
|- | |- | ||
|HgCdTe (MCT) | |HgCdTe (MCT) | ||
− | | | + | |3 - 5 |
| | | | ||
|Axiom ZephIR | |Axiom ZephIR | ||
Line 65: | Line 65: | ||
|- | |- | ||
|Microbolometer | |Microbolometer | ||
− | |[http://support.flir.com/Answers/A932/Ulis_3Elements.png 8 | + | |[http://support.flir.com/Answers/A932/Ulis_3Elements.png 8 - 18] |
| | | | ||
| | | |
Revision as of 18:08, 23 April 2019
\This page focuses on SWIR for IC failure analysis. Note silicon bandgap is 1.14 eV => 1087 nm. General notes:
Technology | Typical um | Typical QE
@ ~1087 nm |
Sample cameras | Notes |
---|---|---|---|---|
InGaAs | 0.9 - 1.7 | SUI goodrich SU320KTSW | Very good choice, but relatively high cost | |
HgCdTe (MCT) | 3 - 5 | Axiom ZephIR | ||
IR vidicon | Hamamatsu C2741-03
FJW Find-R-Scope 85700 |
|||
InSb | Very exotic. Don't use this unless you know what you are doing | |||
PtSi | Very exotic. Don't use this unless you know what you are doing | |||
Back illuminated CMOS | Touptek E3ISPM | |||
Basic CMOS | Amscope MU800 | |||
Cooled CCD | Apogee U2 | |||
Basic CCD | Shitty mall camera | |||
Microbolometer | 8 - 18 | Not suitable |
https://www.osti.gov/servlets/purl/1141916
Contents
Emission microscope
Related: "The Research Devices Model F infrared microscope allows observations in the near158 infrared light region in the wavelength range between λ = 800 - 1200 nm (= 0.8 – 1.2 µm) with a maximum 159 magnification of 400 X."
Alpha Innotech FA-1000
Is there a standard microscope or is it more a camera unit + software?
Relatively compact, stand alone camera system. Comes with small rack with computer and chiller. System weighs around 250 lb.
http://www.fainstruments.com/FAQ.htm
Hammumatsu Phemos 50
Hypervision BEAMS
Complete probe station setup. Uses Princeton instruments cameras. For some reason I think they are MCT, but I'm not sure why I believe that.
SWIR camera
Camera
Vendor |
Camera
Model |
Sensor
Technology |
Typical
nm |
Sensor
Resolution |
Pixel
Size (um) |
Sensor
Vendor |
Sensor
Model |
Output | Notes |
---|---|---|---|---|---|---|---|---|---|
Allied Vision Technologies | P-008 | InGaAs | 900-1700 | ||||||
Allied Vision Technologies | P-032 | InGaAs | 900-1700 | ||||||
Alpha Innotech | FA-1000 | FIXME | See above section | ||||||
Axiom | ZephIR | MCT | |||||||
FLIR Systems | Alpha NIR | InGaAs | 900-1700 | 320x256 | 30x30 | ||||
FLIR Systems | Tua SWIR | 640x512 | |||||||
FJW | Find-R-Scope 85700 | ||||||||
Hamamatsu | C10633-13
C10633-23 |
32x256 | USB
Analogic |
||||||
Hamamatsu | C10633-34 | 640x512 | Analogic | RS-232 control
Liquid cooled | |||||
Hamamatsu | C2741-03 | ||||||||
Hamamatsu | C5840 | ||||||||
ICI | DetectIR | MCT | 3000-5000 | 640x480 | Camcorder
Listed on eBay for $83k | ||||
Princeton Instruments | OMAV | 1000-2000 | Linear | Spectrometer | |||||
Princeton Instruments | PloNIR | InGaAs
TEC |
400-1700 | 640x512 | GigE | ||||
Sensors Unlimited / SUI Goodrich | SU320KTSW | ||||||||
Xenics | XC117 | InGaAs |