Difference between revisions of "Infrared"
(→SWIR camera) (Tag: Visual edit) |
(Tag: Visual edit) |
||
Line 68: | Line 68: | ||
Relatively compact, stand alone camera system. Comes with small rack with computer and chiller. System weighs around 250 lb. | Relatively compact, stand alone camera system. Comes with small rack with computer and chiller. System weighs around 250 lb. | ||
+ | <nowiki>http://www.fainstruments.com/FAQ.htm</nowiki> | ||
+ | |||
+ | ==== Hammumatsu Phemos 50 ==== | ||
+ | <br /> | ||
====Hypervision BEAMS==== | ====Hypervision BEAMS==== | ||
Complete probe station setup. Uses Princeton instruments cameras. For some reason I think they are MCT, but I'm not sure why I believe that. | Complete probe station setup. Uses Princeton instruments cameras. For some reason I think they are MCT, but I'm not sure why I believe that. | ||
Line 216: | Line 220: | ||
| | | | ||
| | | | ||
+ | |- | ||
+ | |ICI | ||
+ | |DetectIR | ||
+ | |MCT | ||
+ | |3000-5000 | ||
+ | |640x480 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |Camcorder | ||
+ | Listed on eBay for $83k | ||
|- | |- | ||
|Princeton Instruments | |Princeton Instruments | ||
Line 252: | Line 268: | ||
|- | |- | ||
|Xenics | |Xenics | ||
− | | | + | |XC117 |
− | | | + | |InGaAs |
| | | | ||
| | | |
Revision as of 08:09, 23 April 2019
This page focuses on SWIR for IC failure analysis. Note silicon bandgap is 1.14 eV => 1087 nm. General notes:
Technology | Typical um | Typical QE
@ ~1087 nm |
Sample cameras | Notes |
---|---|---|---|---|
InGaAs | 0.9 to 1.7 | SUI goodrich SU320KTSW | Very good choice, but relatively high cost | |
HgCdTe (MCT) | Axiom ZephIR | |||
IR vidicon | Hamamatsu C2741-03
FJW Find-R-Scope 85700 |
|||
Back illuminated CMOS | Touptek E3ISPM | |||
Basic CMOS | Amscope MU800 | |||
Cooled CCD | Apogee U2 | |||
Basic CCD | Shitty mall camera | |||
Microbolometer | Cuts of at around 1.4 um or something like that
Not suitable for emission use |
Contents
Emission microscope
Alpha Innotech FA-1000
Is there a standard microscope or is it more a camera unit + software?
Relatively compact, stand alone camera system. Comes with small rack with computer and chiller. System weighs around 250 lb.
http://www.fainstruments.com/FAQ.htm
Hammumatsu Phemos 50
Hypervision BEAMS
Complete probe station setup. Uses Princeton instruments cameras. For some reason I think they are MCT, but I'm not sure why I believe that.
SWIR camera
Camera
Vendor |
Camera
Model |
Sensor
Technology |
Typical
nm |
Sensor
Resolution |
Pixel
Size (um) |
Sensor
Vendor |
Sensor
Model |
Output | Notes |
---|---|---|---|---|---|---|---|---|---|
Allied Vision Technologies | P-008 | InGaAs | 900-1700 | ||||||
Allied Vision Technologies | P-032 | InGaAs | 900-1700 | ||||||
Alpha Innotech | FA-1000 | FIXME | See above section | ||||||
Axiom | ZephIR | MCT | |||||||
FLIR Systems | Alpha NIR | InGaAs | 900-1700 | 320x256 | 30x30 | ||||
FLIR Systems | Tua SWIR | 640x512 | |||||||
FJW | Find-R-Scope 85700 | ||||||||
Hamamatsu | C10633-13
C10633-23 |
32x256 | USB
Analogic |
||||||
Hamamatsu | C10633-34 | 640x512 | Analogic | RS-232 control
Liquid cooled | |||||
Hamamatsu | C2741-03 | ||||||||
Hamamatsu | C5840 | ||||||||
ICI | DetectIR | MCT | 3000-5000 | 640x480 | Camcorder
Listed on eBay for $83k | ||||
Princeton Instruments | OMAV | 1000-2000 | Linear | Spectrometer | |||||
Princeton Instruments | PloNIR | InGaAs
TEC |
400-1700 | 640x512 | GigE | ||||
Sensors Unlimited / SUI Goodrich | SU320KTSW | ||||||||
Xenics | XC117 | InGaAs |