Difference between revisions of "Infrared"
(Tag: Visual edit) |
(→SWIR camera) (Tag: Visual edit) |
||
Line 61: | Line 61: | ||
<br /> | <br /> | ||
− | == Emission microscope == | + | ==Emission microscope== |
− | ==== Alpha Innotech FA-1000 ==== | + | ====Alpha Innotech FA-1000==== |
Is there a standard microscope or is it more a camera unit + software? | Is there a standard microscope or is it more a camera unit + software? | ||
Relatively compact, stand alone camera system. Comes with small rack with computer and chiller. System weighs around 250 lb. | Relatively compact, stand alone camera system. Comes with small rack with computer and chiller. System weighs around 250 lb. | ||
− | ==== Hypervision BEAMS ==== | + | ====Hypervision BEAMS==== |
Complete probe station setup. Uses Princeton instruments cameras. For some reason I think they are MCT, but I'm not sure why I believe that. | Complete probe station setup. Uses Princeton instruments cameras. For some reason I think they are MCT, but I'm not sure why I believe that. | ||
− | == SWIR camera == | + | ==SWIR camera== |
{| class="wikitable" | {| class="wikitable" | ||
|+ | |+ | ||
Line 80: | Line 80: | ||
!Sensor | !Sensor | ||
Technology | Technology | ||
+ | !Typical | ||
+ | nm | ||
+ | !Sensor | ||
+ | Resolution | ||
+ | !Pixel | ||
+ | Size (um) | ||
!Sensor | !Sensor | ||
Vendor | Vendor | ||
!Sensor | !Sensor | ||
Model | Model | ||
+ | !Output | ||
!Notes | !Notes | ||
+ | |- | ||
+ | |Allied Vision Technologies | ||
+ | |P-008 | ||
+ | |InGaAs | ||
+ | |900-1700 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |Allied Vision Technologies | ||
+ | |P-032 | ||
+ | |InGaAs | ||
+ | |900-1700 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |Alpha Innotech | ||
+ | |FA-1000 | ||
+ | |FIXME | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
|- | |- | ||
|Axiom | |Axiom | ||
|ZephIR | |ZephIR | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |FLIR Systems | ||
+ | |Alpha NIR | ||
+ | |InGaAs | ||
+ | |900-1700 | ||
+ | |320x256 | ||
+ | |30x30 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |FLIR Systems | ||
+ | |Tua SWIR | ||
+ | | | ||
+ | | | ||
+ | |640x512 | ||
+ | | | ||
| | | | ||
| | | | ||
Line 99: | Line 165: | ||
| | | | ||
| | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |Hamamatsu | ||
+ | |C10633-13 | ||
+ | C10633-23 | ||
+ | | | ||
+ | | | ||
+ | |32x256 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |USB | ||
+ | Analogic | ||
+ | | | ||
+ | |- | ||
+ | |Hamamatsu | ||
+ | |C10633-34 | ||
+ | | | ||
+ | | | ||
+ | |640x512 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |Analogic | ||
+ | |RS-232 control | ||
+ | Liquid cooled | ||
|- | |- | ||
|Hamamatsu | |Hamamatsu | ||
|C2741-03 | |C2741-03 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
| | | | ||
| | | | ||
Line 107: | Line 206: | ||
| | | | ||
|- | |- | ||
− | | | + | |Hamamatsu |
− | | | + | |C5840 |
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | |Princeton Instruments | ||
+ | |OMAV | ||
+ | | | ||
+ | |1000-2000 | ||
+ | |Linear | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |Spectrometer | ||
+ | |- | ||
+ | |Princeton Instruments | ||
+ | |PloNIR | ||
+ | |InGaAs | ||
+ | TEC | ||
+ | |400-1700 | ||
+ | |640x512 | ||
| | | | ||
| | | | ||
| | | | ||
+ | |GigE | ||
| | | | ||
|- | |- | ||
+ | |Sensors Unlimited / SUI Goodrich | ||
+ | |SU320KTSW | ||
+ | | | ||
+ | | | ||
| | | | ||
| | | | ||
Line 121: | Line 251: | ||
| | | | ||
|- | |- | ||
+ | |Xenics | ||
+ | | | ||
+ | | | ||
+ | | | ||
| | | | ||
| | | |
Revision as of 07:04, 23 April 2019
This page focuses on SWIR for IC failure analysis. Note silicon bandgap is 1.14 eV => 1087 nm. General notes:
Technology | Typical um | Typical QE
@ ~1087 nm |
Sample cameras | Notes |
---|---|---|---|---|
InGaAs | 0.9 to 1.7 | SUI goodrich SU320KTSW | Very good choice, but relatively high cost | |
HgCdTe (MCT) | Axiom ZephIR | |||
IR vidicon | Hamamatsu C2741-03
FJW Find-R-Scope 85700 |
|||
Back illuminated CMOS | Touptek E3ISPM | |||
Basic CMOS | Amscope MU800 | |||
Cooled CCD | Apogee U2 | |||
Basic CCD | Shitty mall camera | |||
Microbolometer | Cuts of at around 1.4 um or something like that
Not suitable for emission use |
Emission microscope
Alpha Innotech FA-1000
Is there a standard microscope or is it more a camera unit + software?
Relatively compact, stand alone camera system. Comes with small rack with computer and chiller. System weighs around 250 lb.
Hypervision BEAMS
Complete probe station setup. Uses Princeton instruments cameras. For some reason I think they are MCT, but I'm not sure why I believe that.
SWIR camera
Camera
Vendor |
Camera
Model |
Sensor
Technology |
Typical
nm |
Sensor
Resolution |
Pixel
Size (um) |
Sensor
Vendor |
Sensor
Model |
Output | Notes |
---|---|---|---|---|---|---|---|---|---|
Allied Vision Technologies | P-008 | InGaAs | 900-1700 | ||||||
Allied Vision Technologies | P-032 | InGaAs | 900-1700 | ||||||
Alpha Innotech | FA-1000 | FIXME | |||||||
Axiom | ZephIR | ||||||||
FLIR Systems | Alpha NIR | InGaAs | 900-1700 | 320x256 | 30x30 | ||||
FLIR Systems | Tua SWIR | 640x512 | |||||||
FJW | Find-R-Scope 85700 | ||||||||
Hamamatsu | C10633-13
C10633-23 |
32x256 | USB
Analogic |
||||||
Hamamatsu | C10633-34 | 640x512 | Analogic | RS-232 control
Liquid cooled | |||||
Hamamatsu | C2741-03 | ||||||||
Hamamatsu | C5840 | ||||||||
Princeton Instruments | OMAV | 1000-2000 | Linear | Spectrometer | |||||
Princeton Instruments | PloNIR | InGaAs
TEC |
400-1700 | 640x512 | GigE | ||||
Sensors Unlimited / SUI Goodrich | SU320KTSW | ||||||||
Xenics |