<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>http://microwiki.org/wiki/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Test</id>
	<title>Microwiki - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="http://microwiki.org/wiki/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Test"/>
	<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php/Special:Contributions/Test"/>
	<updated>2026-04-04T16:09:58Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.31.1</generator>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH2-UMA&amp;diff=370</id>
		<title>Olympus BH2-UMA</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH2-UMA&amp;diff=370"/>
		<updated>2018-12-26T12:14:05Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
This has many parts. See the BH-2 page for a list of accessories.  Comes with slider blanks so that dust doesn't get in.&lt;br /&gt;
&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_0.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_1.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_2.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_4.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_5.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_6.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_7.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= Removing cubes =&lt;br /&gt;
&lt;br /&gt;
[[File:microscope_olympus_bh2-udf_removing.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
The cubes have a (6-32?) threaded part.  The illuminator should have a black screw/knob on the side for this but commodity screws can be used if its missing.  Thread the screw in and gently pull the cube out.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= Calibration procedure =&lt;br /&gt;
&lt;br /&gt;
Notes for calibrating CNC microscope to get optimal images and maximum light output&lt;br /&gt;
&lt;br /&gt;
First read &amp;quot;BH2-UMA Universal Veritcal Illuminator Instruction Manual&amp;quot;.  It details the following alignments:&lt;br /&gt;
* Centering light source (pg 21)&lt;br /&gt;
** With and without centering screen&lt;br /&gt;
** Centering screen enlarges image to make it a little easier&lt;br /&gt;
* Centering field iris diaphragm (pg 22)&lt;br /&gt;
* Adjusting field iris diaphragm (pg 23)&lt;br /&gt;
* Adjusting aperature iris diaphragm (pg 23)&lt;br /&gt;
&lt;br /&gt;
Setup:&lt;br /&gt;
* BH2-TR30 observation tube&lt;br /&gt;
* LH50A lamphouse&lt;br /&gt;
* Mitutoyo M Plan Apo objectives&lt;br /&gt;
* Special issue microscope body&lt;br /&gt;
* Custom built stage&lt;br /&gt;
&lt;br /&gt;
Adjustments / degredation sources:&lt;br /&gt;
* Lamphouse can be rolled by loosening screw on side and turning it&lt;br /&gt;
* Lamp can be moved a in/out by turning screw on side&lt;br /&gt;
* Lamp can be moved a little more in/out by loosening screw on side&lt;br /&gt;
* Lamp can be tilted up/down by loosening screw on side&lt;br /&gt;
* Objective can be misaligned if rail is not in entirely&lt;br /&gt;
* DIC prisms can cause misalignment based on collet position&lt;br /&gt;
* Stage can be uneven for variety of machined surfaces not being tight&lt;br /&gt;
* BH2-UMA may not be aligned to observation tube...issue?&lt;br /&gt;
* BH2-UMA may not be centered from the two setscrews on the sides&lt;br /&gt;
* BH2-UMA has pinhole centering screws&lt;br /&gt;
* BH2-UMA has iris centering screws&lt;br /&gt;
* Cube misalignment/issues?&lt;br /&gt;
* Prism misalignment in observation tube?&lt;br /&gt;
* Camera not stable in observation tube&lt;br /&gt;
* BH2-UMA to observation tube misalignment&lt;br /&gt;
* Wrong lamphouse bulb&lt;br /&gt;
* Dirty objective&lt;br /&gt;
* Broken objective&lt;br /&gt;
* Ensure cube fully engaged&lt;br /&gt;
* Dirty cube&lt;br /&gt;
* Broken lamphouse IR filter&lt;br /&gt;
* Polarizers installed when not needed&lt;br /&gt;
* Observation tube camera/eyepiece slider not on position&lt;br /&gt;
* Sample is uneven&lt;br /&gt;
&lt;br /&gt;
= Collector lens =&lt;br /&gt;
&lt;br /&gt;
== UCLW ==&lt;br /&gt;
&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_3.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
For halogen lamp&lt;br /&gt;
&lt;br /&gt;
== ? ==&lt;br /&gt;
&lt;br /&gt;
For mercury lamp&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH2-UMA&amp;diff=369</id>
		<title>Olympus BH2-UMA</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH2-UMA&amp;diff=369"/>
		<updated>2018-12-26T12:13:35Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
This has many parts. See the BH-2 page for a list of accessories.  Comes with slider blanks so that dust doesn't get in.&lt;br /&gt;
&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_0.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_1.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_2.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_4.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_5.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_6.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_7.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= Removing cubes =&lt;br /&gt;
&lt;br /&gt;
[[File:microscope_olympus_bh2-udf_removing.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
The cubes have a (6-32?) threaded part.  The illuminator should have a black screw/knob on the side for this but commodity screws can be used if its missing.  Thread the screw in and gently pull the cube out.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= Calibration procedure =&lt;br /&gt;
&lt;br /&gt;
Notes for calibrating CNC microscope to get optimal images and maximum light output&lt;br /&gt;
&lt;br /&gt;
First read &amp;quot;BH2-UMA Universal Veritcal Illuminator Instruction Manual&amp;quot;.  It details the following alignments:&lt;br /&gt;
* Centering light source (pg 21)&lt;br /&gt;
** With and without centering screen&lt;br /&gt;
** Centering screen enlarges image to make it a little easier&lt;br /&gt;
* Centering field iris diaphragm (pg 22)&lt;br /&gt;
* Adjusting field iris diaphragm (pg 23)&lt;br /&gt;
* Adjusting aperature iris diaphragm (pg 23)&lt;br /&gt;
&lt;br /&gt;
Setup:&lt;br /&gt;
* BH2-TR30 observation tube&lt;br /&gt;
* LH50A lamphouse&lt;br /&gt;
* Mitutoyo M Plan Apo objectives&lt;br /&gt;
* Special issue microscope body&lt;br /&gt;
* Custom built stage&lt;br /&gt;
&lt;br /&gt;
Adjustments / degredation sources:&lt;br /&gt;
* Lamphouse can be rolled by loosening screw on side and turning it&lt;br /&gt;
* Lamp can be moved a in/out by turning screw on side&lt;br /&gt;
* Lamp can be moved a little more in/out by loosening screw on side&lt;br /&gt;
* Lamp can be tilted up/down by loosening screw on side&lt;br /&gt;
* Objective can be misaligned if rail is not in entirely&lt;br /&gt;
* DIC prisms can cause misalignment based on collet position&lt;br /&gt;
* Stage can be uneven for variety of machined surfaces not being tight&lt;br /&gt;
* BH2-UMA may not be aligned to observation tube...issue?&lt;br /&gt;
* BH2-UMA may not be centered from the two setscrews on the sides&lt;br /&gt;
* BH2-UMA has pinhole centering screws&lt;br /&gt;
* BH2-UMA has iris centering screws&lt;br /&gt;
* Cube misalignment/issues?&lt;br /&gt;
* Prism misalignment in observation tube?&lt;br /&gt;
* Camera not stable in observation tube&lt;br /&gt;
* BH2-UMA to observation tube misalignment&lt;br /&gt;
* Wrong lamphouse bulb&lt;br /&gt;
* Dirty objective&lt;br /&gt;
* Broken objective&lt;br /&gt;
* Ensure cube fully engaged&lt;br /&gt;
* Dirty cube&lt;br /&gt;
* Broken lamphouse IR filter&lt;br /&gt;
* Polarizers installed when not needed&lt;br /&gt;
* Observation tube camera/eyepiece slider not on position&lt;br /&gt;
* Sample is uneven&lt;br /&gt;
&lt;br /&gt;
= UCLW =&lt;br /&gt;
&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_3.jpg|300 px]]&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH2-UMA&amp;diff=368</id>
		<title>Olympus BH2-UMA</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH2-UMA&amp;diff=368"/>
		<updated>2018-12-26T12:13:17Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
This has many parts. See the BH-2 page for a list of accessories.  Comes with slider blanks so that dust doesn't get in.&lt;br /&gt;
&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_0.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_1.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_2.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_3.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_4.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_5.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_6.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_7.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= Removing cubes =&lt;br /&gt;
&lt;br /&gt;
[[File:microscope_olympus_bh2-udf_removing.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
The cubes have a (6-32?) threaded part.  The illuminator should have a black screw/knob on the side for this but commodity screws can be used if its missing.  Thread the screw in and gently pull the cube out.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= Calibration procedure =&lt;br /&gt;
&lt;br /&gt;
Notes for calibrating CNC microscope to get optimal images and maximum light output&lt;br /&gt;
&lt;br /&gt;
First read &amp;quot;BH2-UMA Universal Veritcal Illuminator Instruction Manual&amp;quot;.  It details the following alignments:&lt;br /&gt;
* Centering light source (pg 21)&lt;br /&gt;
** With and without centering screen&lt;br /&gt;
** Centering screen enlarges image to make it a little easier&lt;br /&gt;
* Centering field iris diaphragm (pg 22)&lt;br /&gt;
* Adjusting field iris diaphragm (pg 23)&lt;br /&gt;
* Adjusting aperature iris diaphragm (pg 23)&lt;br /&gt;
&lt;br /&gt;
Setup:&lt;br /&gt;
* BH2-TR30 observation tube&lt;br /&gt;
* LH50A lamphouse&lt;br /&gt;
* Mitutoyo M Plan Apo objectives&lt;br /&gt;
* Special issue microscope body&lt;br /&gt;
* Custom built stage&lt;br /&gt;
&lt;br /&gt;
Adjustments / degredation sources:&lt;br /&gt;
* Lamphouse can be rolled by loosening screw on side and turning it&lt;br /&gt;
* Lamp can be moved a in/out by turning screw on side&lt;br /&gt;
* Lamp can be moved a little more in/out by loosening screw on side&lt;br /&gt;
* Lamp can be tilted up/down by loosening screw on side&lt;br /&gt;
* Objective can be misaligned if rail is not in entirely&lt;br /&gt;
* DIC prisms can cause misalignment based on collet position&lt;br /&gt;
* Stage can be uneven for variety of machined surfaces not being tight&lt;br /&gt;
* BH2-UMA may not be aligned to observation tube...issue?&lt;br /&gt;
* BH2-UMA may not be centered from the two setscrews on the sides&lt;br /&gt;
* BH2-UMA has pinhole centering screws&lt;br /&gt;
* BH2-UMA has iris centering screws&lt;br /&gt;
* Cube misalignment/issues?&lt;br /&gt;
* Prism misalignment in observation tube?&lt;br /&gt;
* Camera not stable in observation tube&lt;br /&gt;
* BH2-UMA to observation tube misalignment&lt;br /&gt;
* Wrong lamphouse bulb&lt;br /&gt;
* Dirty objective&lt;br /&gt;
* Broken objective&lt;br /&gt;
* Ensure cube fully engaged&lt;br /&gt;
* Dirty cube&lt;br /&gt;
* Broken lamphouse IR filter&lt;br /&gt;
* Polarizers installed when not needed&lt;br /&gt;
* Observation tube camera/eyepiece slider not on position&lt;br /&gt;
* Sample is uneven&lt;br /&gt;
&lt;br /&gt;
= UCLW =&lt;br /&gt;
&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_3.jpg|300 px]]&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_UCLW&amp;diff=367</id>
		<title>Olympus UCLW</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_UCLW&amp;diff=367"/>
		<updated>2018-12-26T12:12:59Z</updated>

		<summary type="html">&lt;p&gt;Test: Blanked the page&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_UCLW&amp;diff=366</id>
		<title>Olympus UCLW</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_UCLW&amp;diff=366"/>
		<updated>2018-12-26T12:12:53Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_3.jpg|300 px]]&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_Turret&amp;diff=365</id>
		<title>Olympus Turret</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_Turret&amp;diff=365"/>
		<updated>2018-12-26T12:12:20Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
= BH, BH2 =&lt;br /&gt;
&lt;br /&gt;
These use the same horizontal linear dovetail turret:&lt;br /&gt;
&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-4nre_bottom.jpg|200 px]]&lt;br /&gt;
&lt;br /&gt;
However, be warned that BH (always?) uses 25 mm (M25) Neo finite objective where as BH2 uses 26 mm (M26) infinity corrected objectives.  Here is the underside of a M25 turret, note that they both look the same:&lt;br /&gt;
&lt;br /&gt;
[[File:zoidberg_bh_neo_turret.jpg|200 px]]&lt;br /&gt;
&lt;br /&gt;
From what I understand, the 25 mm objectives will fit into a 26 mm turret but 26 mm objectives do not fit into a 25 mm turret.  Here is a 26 mm turret:&lt;br /&gt;
&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-4nre_top.jpg|200 px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
There are also RMS turrets:&lt;br /&gt;
&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-5mre_top.jpg|200 px]]&lt;br /&gt;
&lt;br /&gt;
for which you can get plenty of finite objectives and even some infinity such as for MSPlan.  Note that all of the RMS turrets are BF while most, but not all, of the M25/M26 turrets are BF/DF.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= BH3 =&lt;br /&gt;
&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh3-nre5_back.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
Unlike earlier BH, the BH3 is motorized and uses a larger vertical linear dovetail.  I was able to take the 5 position revolving part off of this and transplant it onto BH2 dovetail to make a BH2 compatible.&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_Observation_Tube&amp;diff=364</id>
		<title>Olympus Observation Tube</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_Observation_Tube&amp;diff=364"/>
		<updated>2018-12-26T12:11:42Z</updated>

		<summary type="html">&lt;p&gt;Test: Replaced content with &amp;quot;= BH, BH2, BH3 =  These seem to be compatible at least mechanically.  I am less clear if the finite/infinite optics train comes into play here.  == Binocular ==  == Trinoc...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;= BH, BH2, BH3 =&lt;br /&gt;
&lt;br /&gt;
These seem to be compatible at least mechanically.  I am less clear if the finite/infinite optics train comes into play here.&lt;br /&gt;
&lt;br /&gt;
== Binocular ==&lt;br /&gt;
&lt;br /&gt;
== Trinocular ==&lt;br /&gt;
&lt;br /&gt;
== Other ==&lt;br /&gt;
&lt;br /&gt;
=== U-PMTVC ===&lt;br /&gt;
&lt;br /&gt;
[[File:microscope_olympus_u-pmtvc_box2.jpg|300 px]]&lt;br /&gt;
[[File:microscope_olympus_u-pmtvc_top1.jpg|300 px]]&lt;br /&gt;
[[File:microscope_olympus_u-pmtvc_top2.jpg|300 px]]&lt;br /&gt;
[[File:microscope_olympus_u-pmtvc_bottom.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
C-mount adapter&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_Observation_Tube&amp;diff=363</id>
		<title>Olympus Observation Tube</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_Observation_Tube&amp;diff=363"/>
		<updated>2018-12-26T12:10:16Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
Most info in this table from [Objective designations]&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=1&lt;br /&gt;
!Sample image !!Series !!Description !!Thread !!Tube length (mm) !!Parafocal distance (mm) !!Mag !!Notes &lt;br /&gt;
|-&lt;br /&gt;
|    ||    || Blank  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || A  || A  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || Apo  || Apo  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || C  || C  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || CPL  || CPL  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || DApo  || DApo  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || DPlan  || DPlan  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || DPlan  || DPlanApo  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || EA  || EA  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || FL  || FL  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || LWDC  || LWDC  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || LWDCA  || LWDCA  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || CDPlan  || LWDCDPlan  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || LWDCPlan  || LWDCPlan  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || LWDMPlan  || LWDMPlan  || RMS  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MSPlan  || LWDMSPlan  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MSPlan  || LWDMSPlanApo  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NeoSPlan  || LWDNeoSPlanApo  || M26  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || M  || M  || RMS  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MA  || MA  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MDPlan  || MDPlan  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MNH  || MNH  || RMS  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MNM  || MNM  || RMS  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MPL  || MPL  || RMS  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MPlan  || MPlan  || RMS  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MPLL  || MPLL  || RMS  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MPO  || MPO  || RMS  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MSPlan  || MSPlan  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MSPlan  || MSPlanApo  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MUVFL  || MUVFL  || M26  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NCDPlanFL  || NCDPlanFL  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NCSPlan  || NCSPlan  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NCSPlan  || NCSPlanApo  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NCUVFL  || NCUVFL  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NDA  || NDA  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NEA  || NEA  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || Neo  || Neo  || M25  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NeoDPlan  || NeoDPlan  || M26  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NeoPlan  || NeoPlan  || M25  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NeoSPlan  || NeoSPlan  || M26  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NH  || NH  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NM  || NM  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || PL  || PL  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || Plan  || Plan  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || Plan  || PlanApo  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || Plan  || PlanPL  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || PLL  || PLL  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || PO  || PO  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || PS  || PS  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || SPlan  || SPlan  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || SPlan  || SPlanApo  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || SPlan  || SPlanFL  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || CDPlan  || ULWDCDPlan  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MIRPlan  || ULWDMIRPlan  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MSPlan  || ULWDMSPlan  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NeoSPlan  || ULWDNeoSPlan  || M26  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || UVFL  || UVFL  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || WIMSPlan  || WIMSPlanApo  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || WPlan  || WPlan  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || WPlan  || WPlanApo  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || WPlan  || WPlanFL  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Where:&lt;br /&gt;
&lt;br /&gt;
** Mag: magnification range availible&lt;br /&gt;
** SF: strain free (ie DIC, POL/polarizing, etc)&lt;br /&gt;
** RMS: Royal Microscope Society (RMS) 0.8&amp;quot; diameter x 36 thread-per-inch (TPI)&lt;br /&gt;
** M25: 25 mm diameter&lt;br /&gt;
** M26: 26 MM diameter&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= References =&lt;br /&gt;
&lt;br /&gt;
## Objective designations for BH and BH-2 microscopes [Objective designations]: [http://www.alanwood.net/photography/olympus/microscope-objectives.html http://www.alanwood.net/photography/olympus/microscope-objectives.html]]]&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_Objective&amp;diff=362</id>
		<title>Olympus Objective</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_Objective&amp;diff=362"/>
		<updated>2018-12-26T12:09:50Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
Most info in this table from [Objective designations]&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=1&lt;br /&gt;
!Sample image !!Series !!Description !!Thread !!Tube length (mm) !!Parafocal distance (mm) !!Mag !!Notes &lt;br /&gt;
|-&lt;br /&gt;
|    ||    || Blank  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || A  || A  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || Apo  || Apo  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || C  || C  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || CPL  || CPL  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || DApo  || DApo  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || DPlan  || DPlan  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || DPlan  || DPlanApo  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || EA  || EA  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || FL  || FL  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || LWDC  || LWDC  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || LWDCA  || LWDCA  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || CDPlan  || LWDCDPlan  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || LWDCPlan  || LWDCPlan  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || LWDMPlan  || LWDMPlan  || RMS  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MSPlan  || LWDMSPlan  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MSPlan  || LWDMSPlanApo  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NeoSPlan  || LWDNeoSPlanApo  || M26  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || M  || M  || RMS  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MA  || MA  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MDPlan  || MDPlan  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MNH  || MNH  || RMS  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MNM  || MNM  || RMS  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MPL  || MPL  || RMS  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MPlan  || MPlan  || RMS  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MPLL  || MPLL  || RMS  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MPO  || MPO  || RMS  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MSPlan  || MSPlan  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MSPlan  || MSPlanApo  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MUVFL  || MUVFL  || M26  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NCDPlanFL  || NCDPlanFL  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NCSPlan  || NCSPlan  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NCSPlan  || NCSPlanApo  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NCUVFL  || NCUVFL  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NDA  || NDA  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NEA  || NEA  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || Neo  || Neo  || M25  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NeoDPlan  || NeoDPlan  || M26  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NeoPlan  || NeoPlan  || M25  || 210  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NeoSPlan  || NeoSPlan  || M26  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NH  || NH  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NM  || NM  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || PL  || PL  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || Plan  || Plan  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || Plan  || PlanApo  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || Plan  || PlanPL  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || PLL  || PLL  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || PO  || PO  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || PS  || PS  || RMS  || 160  || 36.65  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || SPlan  || SPlan  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || SPlan  || SPlanApo  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || SPlan  || SPlanFL  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || CDPlan  || ULWDCDPlan  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MIRPlan  || ULWDMIRPlan  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || MSPlan  || ULWDMSPlan  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || NeoSPlan  || ULWDNeoSPlan  || M26  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || UVFL  || UVFL  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || WIMSPlan  || WIMSPlanApo  || RMS  || ∞ f=180  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || WPlan  || WPlan  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || WPlan  || WPlanApo  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    || WPlan  || WPlanFL  || RMS  || 160  || 45  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Where:&lt;br /&gt;
&lt;br /&gt;
** Mag: magnification range availible&lt;br /&gt;
** SF: strain free (ie DIC, POL/polarizing, etc)&lt;br /&gt;
** RMS: Royal Microscope Society (RMS) 0.8&amp;quot; diameter x 36 thread-per-inch (TPI)&lt;br /&gt;
** M25: 25 mm diameter&lt;br /&gt;
** M26: 26 MM diameter&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= References =&lt;br /&gt;
&lt;br /&gt;
## Objective designations for BH and BH-2 microscopes [Objective designations]: [http://www.alanwood.net/photography/olympus/microscope-objectives.html http://www.alanwood.net/photography/olympus/microscope-objectives.html]]]&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_Illuminator&amp;diff=361</id>
		<title>Olympus Illuminator</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_Illuminator&amp;diff=361"/>
		<updated>2018-12-26T12:09:02Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
= BH series =&lt;br /&gt;
&lt;br /&gt;
[[File:microscope_olympus_bh2_lamp_comparison_cimg1784.jpg|300 px]]&lt;br /&gt;
[[File:microscope_olympus_bh2_lamp_comparison_cimg1786.jpg|300 px]]&lt;br /&gt;
[[File:microscope_olympus_bh2_lamp_comparison_cimg1787.jpg|300 px]]&lt;br /&gt;
[[File:microscope_olympus_bh2_lamp_comparison_cimg1789.jpg|300 px]]&lt;br /&gt;
[[File:microscope_olympus_bh2_lamp_comparison_cimg1792.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
The LH-50A and what I think is the BH2-MLSH45/50 look very similar.  The main difference is the illuminator diameter which is much larger on the LH-50A.  The LH-50A actually says LH-50A on it (upper left on second picture, hard to see above) and the other has no model listed on it.&lt;br /&gt;
&lt;br /&gt;
Others:&lt;br /&gt;
* BH2-HLSH45/100 (&amp;quot;100W Halogen Lamp Housing&amp;quot;): much larger and white&lt;br /&gt;
* BH2-LSRF (&amp;quot;Fluoresence Lamp Housing&amp;quot;): requires BH3-UET8 extension tube designed for BH3-MJL bulb holder&lt;br /&gt;
* BH3-MJLT: different construction than others.  Requires &amp;quot;BHS-LSH50 for 8&amp;quot; arm and the BH3-LSH50-10 for for 10&amp;quot; arm&amp;quot;&lt;br /&gt;
&lt;br /&gt;
I've also seen reference to BH2-ULSH80&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH2-UMA&amp;diff=360</id>
		<title>Olympus BH2-UMA</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH2-UMA&amp;diff=360"/>
		<updated>2018-12-26T12:07:08Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
This has many parts. See the BH-2 page for a list of accessories.  Comes with slider blanks so that dust doesn't get in.&lt;br /&gt;
&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_0.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_1.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_2.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_3.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_4.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_5.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_6.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2_uma_7.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= Removing cubes =&lt;br /&gt;
&lt;br /&gt;
[[File:microscope_olympus_bh2-udf_removing.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
The cubes have a (6-32?) threaded part.  The illuminator should have a black screw/knob on the side for this but commodity screws can be used if its missing.  Thread the screw in and gently pull the cube out.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= Calibration procedure =&lt;br /&gt;
&lt;br /&gt;
Notes for calibrating CNC microscope to get optimal images and maximum light output&lt;br /&gt;
&lt;br /&gt;
First read &amp;quot;BH2-UMA Universal Veritcal Illuminator Instruction Manual&amp;quot;.  It details the following alignments:&lt;br /&gt;
* Centering light source (pg 21)&lt;br /&gt;
** With and without centering screen&lt;br /&gt;
** Centering screen enlarges image to make it a little easier&lt;br /&gt;
* Centering field iris diaphragm (pg 22)&lt;br /&gt;
* Adjusting field iris diaphragm (pg 23)&lt;br /&gt;
* Adjusting aperature iris diaphragm (pg 23)&lt;br /&gt;
&lt;br /&gt;
Setup:&lt;br /&gt;
* BH2-TR30 observation tube&lt;br /&gt;
* LH50A lamphouse&lt;br /&gt;
* Mitutoyo M Plan Apo objectives&lt;br /&gt;
* Special issue microscope body&lt;br /&gt;
* Custom built stage&lt;br /&gt;
&lt;br /&gt;
Adjustments / degredation sources:&lt;br /&gt;
* Lamphouse can be rolled by loosening screw on side and turning it&lt;br /&gt;
* Lamp can be moved a in/out by turning screw on side&lt;br /&gt;
* Lamp can be moved a little more in/out by loosening screw on side&lt;br /&gt;
* Lamp can be tilted up/down by loosening screw on side&lt;br /&gt;
* Objective can be misaligned if rail is not in entirely&lt;br /&gt;
* DIC prisms can cause misalignment based on collet position&lt;br /&gt;
* Stage can be uneven for variety of machined surfaces not being tight&lt;br /&gt;
* BH2-UMA may not be aligned to observation tube...issue?&lt;br /&gt;
* BH2-UMA may not be centered from the two setscrews on the sides&lt;br /&gt;
* BH2-UMA has pinhole centering screws&lt;br /&gt;
* BH2-UMA has iris centering screws&lt;br /&gt;
* Cube misalignment/issues?&lt;br /&gt;
* Prism misalignment in observation tube?&lt;br /&gt;
* Camera not stable in observation tube&lt;br /&gt;
* BH2-UMA to observation tube misalignment&lt;br /&gt;
* Wrong lamphouse bulb&lt;br /&gt;
* Dirty objective&lt;br /&gt;
* Broken objective&lt;br /&gt;
* Ensure cube fully engaged&lt;br /&gt;
* Dirty cube&lt;br /&gt;
* Broken lamphouse IR filter&lt;br /&gt;
* Polarizers installed when not needed&lt;br /&gt;
* Observation tube camera/eyepiece slider not on position&lt;br /&gt;
* Sample is uneven&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH2-UMA&amp;diff=359</id>
		<title>Olympus BH2-UMA</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH2-UMA&amp;diff=359"/>
		<updated>2018-12-26T12:06:18Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
This has many parts. See the BH-2 page for a list of accessories.  Comes with slider blanks so that dust doesn't get in.&lt;br /&gt;
&lt;br /&gt;
mcmaster:microscope:olympus:bh2_uma:0.jpg?300}}&lt;br /&gt;
mcmaster:microscope:olympus:bh2_uma:1.jpg?300}}&lt;br /&gt;
mcmaster:microscope:olympus:bh2_uma:2.jpg?300}}&lt;br /&gt;
mcmaster:microscope:olympus:bh2_uma:3.jpg?300}}&lt;br /&gt;
mcmaster:microscope:olympus:bh2_uma:4.jpg?300}}&lt;br /&gt;
mcmaster:microscope:olympus:bh2_uma:5.jpg?300}}&lt;br /&gt;
mcmaster:microscope:olympus:bh2_uma:6.jpg?300}}&lt;br /&gt;
mcmaster:microscope:olympus:bh2_uma:7.jpg?300}}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= Removing cubes =&lt;br /&gt;
&lt;br /&gt;
[[File:microscope_olympus_bh2-udf_removing.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
The cubes have a (6-32?) threaded part.  The illuminator should have a black screw/knob on the side for this but commodity screws can be used if its missing.  Thread the screw in and gently pull the cube out.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= Calibration procedure =&lt;br /&gt;
&lt;br /&gt;
Notes for calibrating CNC microscope to get optimal images and maximum light output&lt;br /&gt;
&lt;br /&gt;
First read &amp;quot;BH2-UMA Universal Veritcal Illuminator Instruction Manual&amp;quot;.  It details the following alignments:&lt;br /&gt;
* Centering light source (pg 21)&lt;br /&gt;
** With and without centering screen&lt;br /&gt;
** Centering screen enlarges image to make it a little easier&lt;br /&gt;
* Centering field iris diaphragm (pg 22)&lt;br /&gt;
* Adjusting field iris diaphragm (pg 23)&lt;br /&gt;
* Adjusting aperature iris diaphragm (pg 23)&lt;br /&gt;
&lt;br /&gt;
Setup:&lt;br /&gt;
* BH2-TR30 observation tube&lt;br /&gt;
* LH50A lamphouse&lt;br /&gt;
* Mitutoyo M Plan Apo objectives&lt;br /&gt;
* Special issue microscope body&lt;br /&gt;
* Custom built stage&lt;br /&gt;
&lt;br /&gt;
Adjustments / degredation sources:&lt;br /&gt;
* Lamphouse can be rolled by loosening screw on side and turning it&lt;br /&gt;
* Lamp can be moved a in/out by turning screw on side&lt;br /&gt;
* Lamp can be moved a little more in/out by loosening screw on side&lt;br /&gt;
* Lamp can be tilted up/down by loosening screw on side&lt;br /&gt;
* Objective can be misaligned if rail is not in entirely&lt;br /&gt;
* DIC prisms can cause misalignment based on collet position&lt;br /&gt;
* Stage can be uneven for variety of machined surfaces not being tight&lt;br /&gt;
* BH2-UMA may not be aligned to observation tube...issue?&lt;br /&gt;
* BH2-UMA may not be centered from the two setscrews on the sides&lt;br /&gt;
* BH2-UMA has pinhole centering screws&lt;br /&gt;
* BH2-UMA has iris centering screws&lt;br /&gt;
* Cube misalignment/issues?&lt;br /&gt;
* Prism misalignment in observation tube?&lt;br /&gt;
* Camera not stable in observation tube&lt;br /&gt;
* BH2-UMA to observation tube misalignment&lt;br /&gt;
* Wrong lamphouse bulb&lt;br /&gt;
* Dirty objective&lt;br /&gt;
* Broken objective&lt;br /&gt;
* Ensure cube fully engaged&lt;br /&gt;
* Dirty cube&lt;br /&gt;
* Broken lamphouse IR filter&lt;br /&gt;
* Polarizers installed when not needed&lt;br /&gt;
* Observation tube camera/eyepiece slider not on position&lt;br /&gt;
* Sample is uneven&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH2-ULSH80&amp;diff=358</id>
		<title>Olympus BH2-ULSH80</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH2-ULSH80&amp;diff=358"/>
		<updated>2018-12-26T11:52:39Z</updated>

		<summary type="html">&lt;p&gt;Test: Created page with &amp;quot;Category:Olympus  I can't say for sure this is actually the part I think it is but it came with my BH2-UMA and looks similar to the illuminator in the diagrams.  The conne...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
I can't say for sure this is actually the part I think it is but it came with my BH2-UMA and looks similar to the illuminator in the diagrams.  The connector might not be standard as mine goes to a Nikon power supply.&lt;br /&gt;
&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-ulsh80_0.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-ulsh80_1.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-ulsh80_2.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-ulsh80_3.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-ulsh80_4.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-ulsh80_5.jpg|300 px]]&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_bh2-ulsh80&amp;diff=357</id>
		<title>Olympus bh2-ulsh80</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_bh2-ulsh80&amp;diff=357"/>
		<updated>2018-12-26T11:52:15Z</updated>

		<summary type="html">&lt;p&gt;Test: Blanked the page&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH2-UDF&amp;diff=356</id>
		<title>Olympus BH2-UDF</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH2-UDF&amp;diff=356"/>
		<updated>2018-12-26T11:52:03Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
[[File:microscope_olympus_bh2-udf_0.jpg|300 px]]&lt;br /&gt;
[[File:microscope_olympus_bh2-udf_1.jpg|300 px]]&lt;br /&gt;
[[File:microscope_olympus_bh2-udf_2.jpg|300 px]]&lt;br /&gt;
[[File:microscope_olympus_bh2-udf_3.jpg|300 px]]&lt;br /&gt;
[[File:microscope_olympus_bh2-udf_4.jpg|300 px]]&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH2-RLA&amp;diff=355</id>
		<title>Olympus BH2-RLA</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH2-RLA&amp;diff=355"/>
		<updated>2018-12-26T11:51:44Z</updated>

		<summary type="html">&lt;p&gt;Test: Created page with &amp;quot;Category:Olympus  Filter tube is broken and has severe fungal damage  300 px File:mcmaster_microscope_olympus_bh2-...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
Filter tube is broken and has severe fungal damage&lt;br /&gt;
&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-rla_front.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-rla_lamp_arm_removed.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-rla_perspective_bottom.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-rla_perspective_top.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-rla_top_cover_removed.jpg|300 px]]&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_bh2-rla&amp;diff=354</id>
		<title>Olympus bh2-rla</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_bh2-rla&amp;diff=354"/>
		<updated>2018-12-26T11:51:04Z</updated>

		<summary type="html">&lt;p&gt;Test: Blanked the page&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH2-BI30&amp;diff=353</id>
		<title>Olympus BH2-BI30</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH2-BI30&amp;diff=353"/>
		<updated>2018-12-26T11:50:52Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-bi30_front.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-bi30_bottom.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-bi30_back_left.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh2-bi30_back_right.jpg|300 px]]&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH3-NRE5&amp;diff=352</id>
		<title>Olympus BH3-NRE5</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH3-NRE5&amp;diff=352"/>
		<updated>2018-12-26T11:50:18Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh3-nre5_back.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh3-nre5_side_with_prisms.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh3-nre5_top.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh3-nre5_top_with_prisms.jpg|300 px]]&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh3-nre5_turret_with_prisms.jpg|300 px]]&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH-3&amp;diff=351</id>
		<title>Olympus BH-3</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH-3&amp;diff=351"/>
		<updated>2018-12-26T11:48:39Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
The BH3 is essentially an ergonomic version of the BH2.  It features a motorized turret and more advanced stage mechanisms.&lt;br /&gt;
&lt;br /&gt;
Nosepiece&lt;br /&gt;
* [[Olympus BH3-NRE5]]&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH&amp;diff=350</id>
		<title>Olympus BH</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH&amp;diff=350"/>
		<updated>2018-12-26T11:47:41Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
= Part list =&lt;br /&gt;
&lt;br /&gt;
== Model ==&lt;br /&gt;
&lt;br /&gt;
TODO: add standard metallurgical&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=1&lt;br /&gt;
! Image !! Name !! Description !! Notes&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_system1.jpg|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, cover] [[BHA]  ||  Bottom illumination, removable nosepiece  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BHB]]  ||  Bottom illumination, fixed nosepiece  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BHC]]  ||  Bottom illumination, fixed nosepiece, integrated light source  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BHMJ-02]]  ||  Epi-illumination, sliding stanmd, BF, monocular  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BHMJ-22]]  ||  Epi-illumination, sliding stanmd, BF, binocular  ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_bhmj_and_bhmj-n_bhmj.png|300 px]] &amp;lt;br /&amp;gt;Source: [instruction BHMJ/-N, 3] [[BHMJ-42]  ||    ||  Epi-illumination, sliding stanmd, BF, trinocular  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BHMJ-02-N]]  ||  Epi-illumination, sliding stanmd, BF/DF, monocular  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BHMJ-22-N]]  ||  Epi-illumination, sliding stanmd, BF/DF, binocular  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BHMJ-42-N]]  ||  Epi-illumination, sliding stanmd, BF/DF, trinocular  ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Objective ==&lt;br /&gt;
&lt;br /&gt;
M is BF only.  Neo are BF/DF.  All are M25 threaded&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=1&lt;br /&gt;
! Image !! Part # !! Type !! Description !! Notes&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[M5X]]  ||  Objective  ||  5x  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[M10X]]  ||  Objective  ||  10x  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[M20X]]  ||  Objective  ||  20x  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[M40X]]  ||  Objective  ||  40x  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[Neo5X]]  ||  Objective  ||  5x  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[Neo10X]]  ||  Objective  ||  10x  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[Neo20X]]  ||  Objective  ||  20x  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[Neo40X]]  ||  Objective  ||  40x  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH-RE]]  ||  Nosepiece   ||  Quintuple  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH-RE]]  ||  Nosepiece  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH-NRE]]  ||  Nosepiece  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Illuminator ==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=1&lt;br /&gt;
! Image !! Part # !! Type !! Description !! Notes&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH-MA]]  ||  Illuminator (vertical)  ||  Brightfield  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH-RLA]]  ||  Illuminator (vertical)  ||  Brightfield and darkfield  ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bh-lh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BH-LH]  ||  Lamphouse  ||  Tungsten, 30W  ||  Pre-centered&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH-LHM]]  ||  Lamphouse  ||  Tungsten  ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bh-lsh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BH-LSH]  ||  Lamphouse  ||  Halogen 100W  ||  Centerable&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bh-lh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BH-LH]  ||  Lamphouse  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_ls30.png|100 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[LS30]  ||  Bulb  ||  6V, 30W tungsten ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_ls15.png|100 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[LS15]  ||  Bulb  ||  6V, 15W tungsten  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[FK5X]]  ||  Eyepiece, photo  ||  5x  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[TF]]  ||  Power supply  ||  Transformer  ||  voltage range?&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[45C]]  ||  Filter  ||  for what?  ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_jc12v_100w.png|150 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[jc12v 100W]  ||  Bulb  ||  Halogen  ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Observation tube ==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=1&lt;br /&gt;
! Image !! Part # !! Type !! Description !! Notes&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[CH-M045]]  ||  Observation tube  ||  Monocular  ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bh-swtr.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-SWTR]  ||  Observation tube  ||  Binocular w/ photo?  ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bh-bi30_bi45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-BI30]  ||  Observation tube  ||  Binocular, 30 degree  ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bh-bi30_bi45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-BI45]  ||  Observation tube  ||  Binocular, 45 degree  ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bh-tr30_tr45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-TR30]  ||  Observation tube  ||  Binocular, 30 degree (w/ photo)  ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bh-tr30_tr45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-TR45]  ||  Observation tube  ||  Binocular, 45 degree (w/ photo)  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BiWF10X]]  ||  Eyepiece  ||  HEP, paired  ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_emm-vi.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[EMM-VI]  ||    ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_pm-10-35a.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-10-35A]  ||    ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_pm-10-35l2a.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-10-35L2A]  ||    ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_pm-10-35m.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-10-35M]  ||    ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_pm-6.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-6]  ||    ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Misc ==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=1&lt;br /&gt;
! Image !! Part # !! Type !! Description !! Notes&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:zoidberg_bh_neo_turret.jpg|200 px]] [[BH-RE]  ||  Nosepiece   ||  Quintuple  ||  Neo objectives (M25)&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bha-f.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BHA-F]  ||  Stand  ||  Bottom illumination, removable nosepiece  ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bhb-f.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BHB-F]  ||  Stand  ||  Bottom illumination, fixed nosepiece  ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bhc-f.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BHC-F]  ||  Stand  ||  Bottom illumination, fixed nosepiece, integrated light  ||  Lowest cost?&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bh-sv.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-SV]  ||  Stage  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bh-cd.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-CD]  ||  Condenser  ||  Abbe  ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bh-aac.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-AAC]  ||  Condenser  ||  Ach/Apla  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BHMJ-ST]], [[BHMJ-F]]  ||  Body/base  ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[FK3.3X]]  ||  Photo eyepiece  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[32.5C]]  ||  Blue filter  ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_ah-ca.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[AH-CA]  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_ah-fa.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[AH-FA]  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bh-dcd.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-DCD]  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bh-dcw.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-DCW]  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bh-pc.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-PC]  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bh-sh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-SH]  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[File:olympus_series_bh_microscope_bh-swc.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-SWC]  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= BHA/BHB/BHC configurations =&lt;br /&gt;
&lt;br /&gt;
[[File:olympus_series_bh_microscope_system1.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
Above: probably a BHA.  Source: [BH microscope, cover]&lt;br /&gt;
&lt;br /&gt;
Source: [BH microscope, 18]&lt;br /&gt;
&lt;br /&gt;
NOTE: -1, -2, etc are my notation for the color columns in [BH microscope, 18]&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=1&lt;br /&gt;
! Part # !! Type !! Description !! BHA-1 !! BHA-2 !! BHA-3 !! BHA-4 !! BHB-1 !! BHB-2 !! BHB-3 !! BHB-4 !! BHC-1 !! BHC-2&lt;br /&gt;
|-&lt;br /&gt;
|  [[BHA-F]]  ||  Stand  ||    ||  Y  ||  Y  ||  Y  ||  Y  ||    ||    ||    ||    ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[BHB-F]]  ||  Stand  ||    ||    ||    ||    ||    ||  Y  ||  Y  ||  Y  ||  Y  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[BHC-F]]  ||  Stand  ||    ||    ||    ||    ||    ||    ||    ||    ||    ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|  [[BH-RE]]  ||  Nosepiece   ||  Quintuple  ||  Y  ||  Y  ||  Y  ||  Y  ||    ||    ||    ||    ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[BH-LH]]  ||  Lamphouse  ||    ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[LS30]]  ||  Bulb  ||  6V, 30W  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[LS15]]  ||  Bulb  ||  6V, 15W  ||    ||    ||    ||    ||    ||    ||    ||    ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|  [[BH-BI45]]  ||  Observation tube  ||  45 deg binocular  ||    ||  Y  ||    ||  Y  ||    ||  Y  ||    ||  Y  ||    ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|  [[BH-TR45]]  ||  Observation tube  ||  45 deg trinocular  ||  Y  ||    ||  Y  ||    ||  Y  ||    ||  Y  ||    ||  Y  ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[BH-SV]]  ||  Stage  ||    ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|  [[BH-CD]]  ||  Condenser  ||  Abbe  ||    ||    ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|  [[BH-AAC]]  ||  Condenser  ||  Ach/Apla  ||  Y  ||  Y  ||    ||    ||    ||    ||    ||    ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  Objective  ||  Achromat 4x, 10x, S-40x (spring), S-100x (spring, oil) set  ||    ||    ||  Y  ||  Y  ||    ||    ||  Y  ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|    ||  Objective  ||  Plan achromat 4x, 10x, 40x (spring), 100x (spring, oil) set  ||  Y  ||  Y  ||    ||    ||  Y  ||  Y  ||    ||    ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  Objective  ||  Plan achromat 20x (spring)  ||  Y  ||  Y  ||    ||    ||    ||    ||    ||    ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[BiWF10X]]  ||  Eyepiece  ||  HEP, paired  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|  [[FK5X]]  ||  Eyepiece, photo  ||  5x  ||  Y  ||    ||  Y  ||    ||  Y  ||    ||  Y  ||    ||  Y  ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[45C]]  ||  Filter  ||  for what?  ||    ||    ||    ||    ||    ||    ||    ||    ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|    ||  Bulb  ||  Spare bulb (2x)  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|    ||  Fuse  ||  Spare fuse (2x)  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|    ||  Oil  ||  Immersion oil  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|    ||  Cover  ||  Vintyl dust cover  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= BHMJ configurations =&lt;br /&gt;
&lt;br /&gt;
[[File:olympus_bhmj_and_bhmj-n_bhmj.png|300 px]]&lt;br /&gt;
&lt;br /&gt;
Above: A BHMJ, probably a BHMJ-42.  Source: [instruction BHMJ/-N, 3]&lt;br /&gt;
&lt;br /&gt;
Source: [instruction BHMJ/-N, 2]&lt;br /&gt;
&lt;br /&gt;
-N adds darkfield&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=1&lt;br /&gt;
! Part # !! Type !! Description !! BHMJ-02 !! BHMJ-22 !! BHMJ-42 !! BHMJ-02-N !! BHMJ-22-N !! BHMJ-42-N&lt;br /&gt;
|-&lt;br /&gt;
|  [[BHMJ-ST]], [[BHMJ-F]]  ||  Body/base  ||    ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|  [[BH-RE]]  ||  Nosepiece  ||    ||  Y  ||  Y  ||  Y  ||    ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[BH-NRE]]  ||  Nosepiece  ||     ||    ||    ||    ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|  [[BH-MA]]  ||  Illuminator (vertical)  ||  Brightfield  ||  Y  ||  Y  ||  Y  ||    ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[BH-RLA]]  ||  Illuminator (vertical)  ||  Brightfield and darkfield  ||    ||    ||    ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|  [[CH-M045]]  ||  Observation tube  ||  Monocular   ||  Y  ||    ||    ||  Y  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[BH-BI45]]  ||  Observation tube  ||  Monocular  ||    ||  Y  ||    ||    ||  Y  ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[BH-TR45]]  ||  Observation tube  ||  Binocular (w/ photo)  ||    ||    ||  Y  ||    ||    ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|  [[BH-LHM]]  ||  Lamphouse  ||  Tungsten  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|  [[LS15]]  ||  Bulb  ||  15W tungsten  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|  [[TF]]  ||  Power supply  ||  Transformer  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|  [[M5X]] &amp;lt;br /&amp;gt;[[M10X]] &amp;lt;br /&amp;gt;[[M20X]] &amp;lt;br /&amp;gt;[[M40X]]  ||  Objective  ||  Set  ||  Y  ||  Y  ||  Y  ||    ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[Neo5X]] &amp;lt;br /&amp;gt;[[Neo10X]] &amp;lt;br /&amp;gt;[[Neo20X]] &amp;lt;br /&amp;gt;[[Neo40x]]  ||  Objective  ||  Set  ||    ||    ||    ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|    ||  High eyepoint BiWF10X,paired eyepiece   ||    ||  Y  ||  Y  ||    ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|    ||  High eyepoint WF10X eyepiece  ||  Y  ||    ||    ||  Y  ||    ||&lt;br /&gt;
|-&lt;br /&gt;
|  [[FK3.3X]]  ||  Photo eyepiece  ||    ||    ||  Y  ||    ||    ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|    ||  Stage plate  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|    ||  Stage clips  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|    ||  Eyepiece caps   ||    ||  Y  ||  Y  ||    ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|  [[32.5C]]  ||  Blue filter  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|    ||  Vinyl dust cover  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y  ||  Y&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= References =&lt;br /&gt;
&lt;br /&gt;
* Olympus Series BH System Microscope [BH microscope]: [http://www.alanwood.net/downloads/olympus-bh-bha-bhb-bhc-brochure.pdf]&lt;br /&gt;
* Olympus metallurgical microscopes instruction manual, models BHMJ &amp;amp; BHMJ-N [instruction BHMJ/-N]: [http://www.alanwood.net/downloads/olympus-bhmj-bhmj-n-instructions.pdf]&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Zoidberg_bh_neo_turret.jpg&amp;diff=349</id>
		<title>File:Zoidberg bh neo turret.jpg</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Zoidberg_bh_neo_turret.jpg&amp;diff=349"/>
		<updated>2018-12-26T11:47:14Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH2_Prism_Mount&amp;diff=348</id>
		<title>Olympus BH2 Prism Mount</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH2_Prism_Mount&amp;diff=348"/>
		<updated>2018-12-26T11:42:02Z</updated>

		<summary type="html">&lt;p&gt;Test: Created page with &amp;quot;Category:Olympus  These allow the prisms to be mounted nicely without worry about how they'll happen to line up when you screw them in.  Instead you screw in the prism mou...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
These allow the prisms to be mounted nicely without worry about how they'll happen to line up when you screw them in.  Instead you screw in the prism mount and the prism is rotated as desired and then screwed down with an allen wrench.&lt;br /&gt;
&lt;br /&gt;
[[File:mcmaster_microscope_olympus_bh3-nre5_side_with_prisms.jpg|300 px]]&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH2_prism_mount&amp;diff=347</id>
		<title>Olympus BH2 prism mount</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH2_prism_mount&amp;diff=347"/>
		<updated>2018-12-26T11:39:51Z</updated>

		<summary type="html">&lt;p&gt;Test: Blanked the page&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH2_prism_mount&amp;diff=346</id>
		<title>Olympus BH2 prism mount</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH2_prism_mount&amp;diff=346"/>
		<updated>2018-12-26T11:39:47Z</updated>

		<summary type="html">&lt;p&gt;Test: Created page with &amp;quot;Category:Olympus  These allow the prisms to be mounted nicely without worry about how they'll happen to line up when you screw them in.  Instead you screw in the prism mou...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
These allow the prisms to be mounted nicely without worry about how they'll happen to line up when you screw them in.  Instead you screw in the prism mount and the prism is rotated as desired and then screwed down with an allen wrench.&lt;br /&gt;
&lt;br /&gt;
{{gallery&amp;gt;mcmaster:microscope:olympus:bh3-nre5:side_with_prisms.jpg}}&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_bh2_prism_mount&amp;diff=345</id>
		<title>Olympus bh2 prism mount</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_bh2_prism_mount&amp;diff=345"/>
		<updated>2018-12-26T11:39:38Z</updated>

		<summary type="html">&lt;p&gt;Test: Blanked the page&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH2&amp;diff=344</id>
		<title>Olympus BH2</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH2&amp;diff=344"/>
		<updated>2018-12-26T11:39:02Z</updated>

		<summary type="html">&lt;p&gt;Test: Created page with &amp;quot;Category:Olympus  The BH2 and BH3 are very similiar and so have been combined to the same page. Basically, the BH3 adds motorized turret while keeping the same objectives,...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
The BH2 and BH3 are very similiar and so have been combined to the same page.&lt;br /&gt;
Basically, the BH3 adds motorized turret while keeping the same objectives, observation tube, etc.&lt;br /&gt;
Many of its parts use BH2 rather than BH3 prefix.&lt;br /&gt;
Thus, most of the parts are interchangable.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= Model =&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=1&lt;br /&gt;
! Image !! Name !! Description !! Notes &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH2-BHTP]]  ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH3-MJLA2]]  ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH3-MJLA4]]  ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH3-MJLT2]]  ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH3-MJT4]]  ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH3-MJL]]  ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= BH2-UMA =&lt;br /&gt;
&lt;br /&gt;
{{gallery&amp;gt;:mcmaster:microscope:olympus:bh2_uma:0.jpg}}&lt;br /&gt;
&lt;br /&gt;
[[BH2-UMA]]: universal vertical illuminator&lt;br /&gt;
&lt;br /&gt;
Parts:&lt;br /&gt;
* Mirror units&lt;br /&gt;
''' [[BH2-UBF]]: brighlfield half-mirror unit&lt;br /&gt;
{{gallery&amp;gt;:mcmaster:microscope:olympus:bh2_uma:7.jpg}}&lt;br /&gt;
''' [[BH2-UBFL]]: brightfield half-mirror unit with ND05 filter&lt;br /&gt;
''' [[BH2-UDF]]: darkfield half-mirror unit&lt;br /&gt;
{{gallery&amp;gt;:microscope:olympus:bh2-udf:0.jpg?300|}}&lt;br /&gt;
''' [[BH2-UDMB]]: blue nuorescence half-mirror unit&lt;br /&gt;
''' [[BH2·UDMG]]: green fluorescence half-mirror unit&lt;br /&gt;
''' [[BH2-UDMV]]: violet fluorescence half-mirror unit&lt;br /&gt;
* Sliders / filters&lt;br /&gt;
''' [[BH2-UND]]: ND filler slider, including ND 12 filter&lt;br /&gt;
''' [[BH2-UTP-530]]: tint plate. including NO 12 filter&lt;br /&gt;
''' [[BH2-UFO]]: polarizer&lt;br /&gt;
''' [[BH2-UAN]]: analyzer&lt;br /&gt;
''' [[20LB03-W]]: Light balancing daylight filler&lt;br /&gt;
* [[UCLW]]: halogen collector lens&lt;br /&gt;
{{gallery&amp;gt;:mcmaster:microscope:olympus:bh2_uma:3.jpg}}&lt;br /&gt;
* [[BH2-ULSH80]]: Halogen lamp housing (wilh halogen collector lens)&lt;br /&gt;
{{gallery&amp;gt;:mcmaster:microscope:olympus:bh2-ulsh80:1.jpg}}&lt;br /&gt;
* [[12V SOW HAL]]: halogen bulb&lt;br /&gt;
* [[BH2-TGH]]: transformer&lt;br /&gt;
* [[BH2-URF]]: fluorescence supplementary unit&lt;br /&gt;
''' [[BH2-UFF]]: Supplementary exciter slider&lt;br /&gt;
''' [[BH2-UL]]: fluorescence collector lens&lt;br /&gt;
''' [[BH2-UA]]: supporting block&lt;br /&gt;
''' [[BH2-UCCV]]: UV protective shield&lt;br /&gt;
&lt;br /&gt;
Objective&lt;br /&gt;
* NIC&lt;br /&gt;
''' [[NEOSPL5X-NIC]]: Neo S Plan 5X NIC&lt;br /&gt;
''' [[NEOSPL10X-NIC]]: Neo S Plan 10X NIC&lt;br /&gt;
''' [[NEOSPL20X-NIC]]: Neo S Plan 20X NIC&lt;br /&gt;
''' [[NEOSPL50X-NIC]]: Neo S Plan 50X NIC&lt;br /&gt;
''' [[NEOSPL100X-NIC]]: Neo S Plan 100X NIC&lt;br /&gt;
* Standard achromatic&lt;br /&gt;
''' [[NEOSPL5X]]: Neo S Plan Ach SX&lt;br /&gt;
''' [[NEOSPL10X-T]]: Neo S Plan Acb 1OX&lt;br /&gt;
''' [[NEOSPL20X-T]]: Neo S Plan Ach 20X&lt;br /&gt;
''' [[NEOSPL50X]]: Neo S Plan Ach 5OX &lt;br /&gt;
&lt;br /&gt;
Normanski prism&lt;br /&gt;
{{gallery&amp;gt;:mcmaster:microscope:olympus:bh3-nre5:top_with_prisms.jpg}}&lt;br /&gt;
* [[bh2-prism_mount]]: Normanksi prism mount&lt;br /&gt;
* [[U-NIC5-N]]: Nomarski 5X&lt;br /&gt;
* [[U-NIC10-N]]: Nomarski 10X&lt;br /&gt;
* [[U-NIC20-N]]: Nomarski 20X&lt;br /&gt;
* [[U-NIC50-N]]: Nomarski 50X&lt;br /&gt;
* [[U-NIC100-N]]: Nomarski 100X&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= BH2-RFCA =&lt;br /&gt;
&lt;br /&gt;
Parts:&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=1&lt;br /&gt;
! Image !! Part # !! Type !! Description !! Notes &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH2-LSRF-2]]  ||  Lamphouse  ||  fluoresence  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH2-RFL-T3]]  ||  Power supply  ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[USH-l02D]]  ||  Mercury burner  ||  mercury burner  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH2-LSRH]]  ||  Lamphouse  ||  &amp;quot;halogen lamp housing&amp;quot;  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[TGH]]  ||  Transformer  ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[JC12V50WHAL-L]]  ||  Bulb  ||  Halogen  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[UYCP]]  ||  Cable  ||  power cord  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH2-SGRF]]  ||  Eyepiece  ||  centering screen  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH2-DMU]]  ||  Mirror  ||  Dichrotic assembly: U  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH2-DMV]]  ||  Mirror  ||  Dichrotic assembly: V  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH2-DMBV]]  ||  Mirror  ||  Dichrotic assembly: BV  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH2-DMB]]  ||  Mirror  ||  Dichrotic assembly: B  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH2-DMG]]  ||  Mirror  ||  Dichrotic assembly: G  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH2-DMIB]]  ||  Mirror  ||  Dichrotic assembly: IB  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH2-BF]]  ||  Cube  ||  brightfield  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[20EY455-W22]]  ||  Filter  ||  Supplemental exciting: B  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[20EY475-W22]]  ||  Filter  ||  Supplemental exciting: IB  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[2OE0515-W22]]  ||  Filter  ||  Supplemental exciting: G  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[20E0530-W22]]  ||  Filter  ||  Supplemental exciting: G  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[20EL420-W22]]  ||  Filter  ||  Supplemental exciting: BV  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[20L435-W22]]  ||  Filter  ||  Supplemental barrier: U  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[2OY455-W22]]  ||  Filter  ||  Supplemental barrier: U  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[20Y475-W22]]  ||  Filter  ||  Supplemental barrier: V  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[20Y495-W22]]  ||  Filter  ||  Supplemental barrier: V, BV  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[200515-W22]]  ||  Filter  ||  Supplemental barrier: V, BV  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[2OB460-W22]]  ||  Filter  ||  Supplemental barrier: B, IB  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[2OG520-W22]]  ||  Filter  ||  Supplemental barrier: B, IB  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[20053D-W22]]  ||  Filter  ||  Supplemental barrier: B, IB  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[20057D-W22]]  ||  Filter  ||  Supplemental barrier: B, IB  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[200590-W22]]  ||  Filter  ||  Supplemental barrier: B, IB  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[20R61D-W22]]  ||  Filter  ||  Supplemental barrier: G  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[DPLAP010XUV]]  ||  Objective  ||  10x UV?  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[DPLAP020XUV]]  ||  Objective  ||  40x UV, oil?  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[DPLAP040XUV]]  ||  Objective  ||  40x spring, iris, oil?  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[DPLAP0100XUV]]  ||  Objective  ||  100x spring, iris, oil?  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[DAP040XUV]]  ||  Objective  ||  40x spring, iris, oil?  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[DAP0100XUV]]  ||  Objective  ||  100x spring, iris, oil?  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH2-FLPC]]  ||  Illuminator  ||  flouresence phase contrast  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  DPlanAPO 10x UVPL  ||  Objective  ||    ||  For BH2-FLPC &lt;br /&gt;
|-&lt;br /&gt;
|    ||  DPlanAPO 4Ox oil UVPL  ||  Objective  ||    ||  For BH2-FLPC &lt;br /&gt;
|-&lt;br /&gt;
|    ||  DPlanAPO 100x oil UVPL  ||  Objective  ||    ||  For BH2-FLPC &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH2-ANF]]  ||    ||  analyzer  ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||  [[BH2-NAF]]  ||    ||  prism slider  ||   &lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
The BH3 is essentially an ergonomic version of the BH2.  It features a motorized turret and more advanced stage mechanisms.&lt;br /&gt;
&lt;br /&gt;
Nosepiece&lt;br /&gt;
[[BH3-NRE5]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= BH3 configurations =&lt;br /&gt;
&lt;br /&gt;
== IC (standard) ==&lt;br /&gt;
&lt;br /&gt;
From [Olympus BH3-MJLT &amp;amp; BH3-MJLA IC Inspection Microscope Instructions]&lt;br /&gt;
&lt;br /&gt;
FIXME: adjust columns&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=1&lt;br /&gt;
! Part # !! Type !! Description !! BH3-MJLA2 !! BH3-MJLA4 !! BH3-MJLT2 !! BH3-MJT4 !! BH3-MJL &lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=1&lt;br /&gt;
! Name !! Part # !! BH3-MJLA2 !! BH3-MJLA4 !! BH3-MJLT2 !! BH3-MJT4 !! BH3-MJL &lt;br /&gt;
|-&lt;br /&gt;
| &lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== IC (fluorescence) ==&lt;br /&gt;
&lt;br /&gt;
From [Olympus BH3-MJLT &amp;amp; BH3-MJLA IC Inspection Microscope Instructions]&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=1&lt;br /&gt;
! Name !! Part # !! BH3-MJLA2 !! BH3-MJLA4 !! BH3-MJLT2 !! BH3-MJT4 !! BH3-MJL &lt;br /&gt;
|-&lt;br /&gt;
|  Microscope stand  ||  [[BH3-MJLA2-F]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  Microscope stand  ||  [[BH3-MJLA4-F]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  Microscope stand  ||  [[BH3-MJLT2-F]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  Microscope stand  ||  [[BH3-MJLT4-F]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  Power cord  ||  [[UYCP]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  Trinocular tube  ||  [[BH2-TR30]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  Tilting trinocular tube  ||  [[BH2-TTR]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  Motorized 5 revolving nosepiece (M obj)  ||  [[BH3-5MRE-M]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  Universal vertical illuminator  ||  [[BH2-UMA]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  Brightfield half-mirror unit ND05 filter  ||  [[BH2-UBFL]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  Dichromtic mirror unit (B)  ||  [[BH2-UDMB]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  Dichromtic mirror unit (G)  ||  [[BH2-UDMG]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  Dichromtic mirror unit (V)  ||  [[BH2-UDMV]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  Roof cover  ||  [[BH2-UCO]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  Breath shield  ||  [[BH3-BSH]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  Light balancing filter  ||  [[45BD22-N]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  Fluoresence supplementary unit  ||  [[BH2-URF]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  Extension tube  ||  [[BH3-UETB]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  flourescence lamp housing  ||  [[BH2-LSRF]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  mercury burner  ||  [[USH102D]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  power supply  ||  [[BH2-RFL-T3]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  centering screen  ||  [[BH2-SGRF]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  halogen lamp housing (50W, for transmitted light)  ||  [[BHS-LSH-50]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  halogen bulb  ||  [[JC12V50WHAL-L]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  mechanical stage w/ right-hand low drive controls  ||  [[BH3-SIC6-R]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  mechanical stage w/ right-hand low drive controls  ||  [[BH3-SIC8-R]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  stage grip for right-hand side  ||  [[BH3-SGR-R]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  wafer holder plate  ||  [[BH3-WHP6]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  6&amp;quot; and 5&amp;quot; wafer holder ring  ||  [[BH3-WHR65]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  wafer holder plate including 8&amp;quot; and 6&amp;quot; wafer holder ring  ||  [[BH3-WHPR86]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  5&amp;quot; x 5&amp;quot; mask holder  ||  [[BH3-MH5]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  7&amp;quot; x 7&amp;quot; mask holder  ||  [[BH3-MH7]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  MS PL achromatic objective (5x)  ||  [[MS PL5X]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  MS PL achromatic objective (10x)  ||  [[MS PL10X]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  MS PL achromatic objective (20x)  ||  [[MS PL20X]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  MS PL achromatic objective (50x)  ||  [[MS PL50X]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  MS PL achromatic objective (100x)  ||  [[MS PL100X]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  LB eyepiece 10x  ||  [[WHK10X]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  LB eyepiece 10x w/ built-in 35 mm mask  ||  [[35WHK10X]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|  LB Photo eyepiece 3.3x  ||  [[NFK 3.3X LD]]  ||    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== LCD ==&lt;br /&gt;
&lt;br /&gt;
Polarizing microscope for inspecting LCD screens&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= Illuminators =&lt;br /&gt;
&lt;br /&gt;
Include:&lt;br /&gt;
* [[BH2-UMA]]: powerful unit developed later in the series and used on BH3.  Compatible lamphouses:&lt;br /&gt;
''' [[BH2-ULSH80]]: halogen lamp housing (wilh halogen collector lens)&lt;br /&gt;
''' [[BH2-HLSH]]: 100W version (use UCLW?)&lt;br /&gt;
''' FIXME: mercury burner.  Requires special power supply and HCL collector lens&lt;br /&gt;
* [[BH2-RFCA]]: &amp;quot;Fluorescence Illuminator, including UV Protective Shield, Immersion Oil 50cc and Dust Cover B071&amp;quot;&lt;br /&gt;
''' similar in purpose to BH2-UMA, may even take compatible cubes.  Much less common&lt;br /&gt;
''' My guess is that this was pre-BH2-UMA flouresence option.  BH2-UMA combined all illuminators&lt;br /&gt;
''' Might be intended to be used with [[BHS-RFC]] microscope&lt;br /&gt;
* [[BH2-RLA]]: BF/DF unit?&lt;br /&gt;
* [[BH2-BHA]]: BF only unit?&lt;br /&gt;
&lt;br /&gt;
The illuminator filter assemblies seem to be compatible (or at least fit) between a number of models.  I took my beat up BH2-RLA and was able to swap parts to a BH2-BHA.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= Master part list =&lt;br /&gt;
&lt;br /&gt;
Misc parts (scraped from BH2 manuals):&lt;br /&gt;
* [[BH2-UET]]: extension tube&lt;br /&gt;
* [[BH2-LSRF]]: mercury lamp housing&lt;br /&gt;
* [[USH IQZO]]: mercury lamp&lt;br /&gt;
* [[BH2-RFL]]: power supply unit&lt;br /&gt;
* [[BH2-SGRF]]: centering screen&lt;br /&gt;
* [[BH2-BI30]]: binocular observation tube&lt;br /&gt;
{{gallery&amp;gt;:mcmaster:microscope:olympus:bh2-bi30:front.jpg}}&lt;br /&gt;
* [[BH2-TR30]]: trinocular observation tube&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= Lighting =&lt;br /&gt;
&lt;br /&gt;
Lamphouses, bulbs, power supplies, etc&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=1&lt;br /&gt;
! Part # !! Desc !! BH2? !! BH3? !! Notes &lt;br /&gt;
|-&lt;br /&gt;
|  BH2-UMA  ||    ||    ||    ||  See page for sub-parts &lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= Objectives =&lt;br /&gt;
&lt;br /&gt;
Including accessories such as Normanski prisms&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=1&lt;br /&gt;
! Part # !! Desc !! BH2? !! BH3? !! Notes &lt;br /&gt;
|-&lt;br /&gt;
|    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|    ||    ||    ||    ||   &lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== BH3-NRE5 ==&lt;br /&gt;
&lt;br /&gt;
{{gallery&amp;gt;:mcmaster:microscope:olympus:bh3-nre5:back.jpg}}&lt;br /&gt;
{{gallery&amp;gt;:mcmaster:microscope:olympus:bh3-nre5:side_with_prisms.jpg}}&lt;br /&gt;
{{gallery&amp;gt;:mcmaster:microscope:olympus:bh3-nre5:top.jpg}}&lt;br /&gt;
{{gallery&amp;gt;:mcmaster:microscope:olympus:bh3-nre5:top_with_prisms.jpg}}&lt;br /&gt;
{{gallery&amp;gt;:mcmaster:microscope:olympus:bh3-nre5:turret_with_prisms.jpg}}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= References =&lt;br /&gt;
# BH2-UMA instruction manual: http:''www.alanwood.net/downloads/olympus-bh2-uma-instructions.pdf&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_bh2&amp;diff=343</id>
		<title>Olympus bh2</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_bh2&amp;diff=343"/>
		<updated>2018-12-26T11:38:55Z</updated>

		<summary type="html">&lt;p&gt;Test: Blanked the page&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus&amp;diff=342</id>
		<title>Olympus</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus&amp;diff=342"/>
		<updated>2018-12-26T11:38:37Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
See also: [[:Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
BH2 and such&lt;br /&gt;
&lt;br /&gt;
Optical microscope (OM):&lt;br /&gt;
* [[Olympus EH]]&lt;br /&gt;
* [[Olympus FH]]&lt;br /&gt;
* [[Olympus BH]]&lt;br /&gt;
* [[Olympus BH2]] (and BH3)&lt;br /&gt;
* [[Olympus BX]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= BH series =&lt;br /&gt;
&lt;br /&gt;
The BH2 and BH3 are mostly the same with the addition of the BH3's motorized turret.  BH parts are generally mecanically compatible but optically incompatible with BH2/BH3 due to the move from finite to inifinity optics.  This includes but is not limited to the objective, illuminator, and eyepieces.  If you try to mix them your image quality will degrade.&lt;br /&gt;
&lt;br /&gt;
Ex: the BH RMS nosepiece can be used with finite objectives on the BH and used with MSPlan infinity corrected objectives on the BH2/3.  Thus, while the part is mechanicly compatible the optics aren't.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= References =&lt;br /&gt;
&lt;br /&gt;
http:''www.alanwood.net/photography/olympus/downloads.html#bh2&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus&amp;diff=341</id>
		<title>Olympus</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus&amp;diff=341"/>
		<updated>2018-12-26T11:38:23Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
See also: [[:Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
BH2 and such&lt;br /&gt;
&lt;br /&gt;
Optical microscope (OM):&lt;br /&gt;
* [[Olympus EH]]&lt;br /&gt;
* [[Olympus FH]]&lt;br /&gt;
* [[Olympus BH]]&lt;br /&gt;
* [[Olympus BH2|BH2/BH3]]&lt;br /&gt;
* [[Olympus BX]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= BH series =&lt;br /&gt;
&lt;br /&gt;
The BH2 and BH3 are mostly the same with the addition of the BH3's motorized turret.  BH parts are generally mecanically compatible but optically incompatible with BH2/BH3 due to the move from finite to inifinity optics.  This includes but is not limited to the objective, illuminator, and eyepieces.  If you try to mix them your image quality will degrade.&lt;br /&gt;
&lt;br /&gt;
Ex: the BH RMS nosepiece can be used with finite objectives on the BH and used with MSPlan infinity corrected objectives on the BH2/3.  Thus, while the part is mechanicly compatible the optics aren't.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
= References =&lt;br /&gt;
&lt;br /&gt;
http:''www.alanwood.net/photography/olympus/downloads.html#bh2&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bha-f.png&amp;diff=329</id>
		<title>File:Olympus series bh microscope bha-f.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bha-f.png&amp;diff=329"/>
		<updated>2018-12-26T11:37:41Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bhb-f.png&amp;diff=330</id>
		<title>File:Olympus series bh microscope bhb-f.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bhb-f.png&amp;diff=330"/>
		<updated>2018-12-26T11:37:41Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bhc-f.png&amp;diff=331</id>
		<title>File:Olympus series bh microscope bhc-f.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bhc-f.png&amp;diff=331"/>
		<updated>2018-12-26T11:37:41Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_emm-vi.png&amp;diff=332</id>
		<title>File:Olympus series bh microscope emm-vi.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_emm-vi.png&amp;diff=332"/>
		<updated>2018-12-26T11:37:41Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_jc12v_100w.png&amp;diff=333</id>
		<title>File:Olympus series bh microscope jc12v 100w.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_jc12v_100w.png&amp;diff=333"/>
		<updated>2018-12-26T11:37:41Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_ls15.png&amp;diff=334</id>
		<title>File:Olympus series bh microscope ls15.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_ls15.png&amp;diff=334"/>
		<updated>2018-12-26T11:37:41Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_ls30.png&amp;diff=335</id>
		<title>File:Olympus series bh microscope ls30.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_ls30.png&amp;diff=335"/>
		<updated>2018-12-26T11:37:41Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_pm-10-35a.png&amp;diff=336</id>
		<title>File:Olympus series bh microscope pm-10-35a.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_pm-10-35a.png&amp;diff=336"/>
		<updated>2018-12-26T11:37:41Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_pm-10-35l2a.png&amp;diff=337</id>
		<title>File:Olympus series bh microscope pm-10-35l2a.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_pm-10-35l2a.png&amp;diff=337"/>
		<updated>2018-12-26T11:37:41Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_pm-10-35m.png&amp;diff=338</id>
		<title>File:Olympus series bh microscope pm-10-35m.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_pm-10-35m.png&amp;diff=338"/>
		<updated>2018-12-26T11:37:41Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_pm-6.png&amp;diff=339</id>
		<title>File:Olympus series bh microscope pm-6.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_pm-6.png&amp;diff=339"/>
		<updated>2018-12-26T11:37:41Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_system1.jpg&amp;diff=340</id>
		<title>File:Olympus series bh microscope system1.jpg</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_system1.jpg&amp;diff=340"/>
		<updated>2018-12-26T11:37:41Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bh-dcw.png&amp;diff=320</id>
		<title>File:Olympus series bh microscope bh-dcw.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bh-dcw.png&amp;diff=320"/>
		<updated>2018-12-26T11:37:40Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bh-lh.png&amp;diff=321</id>
		<title>File:Olympus series bh microscope bh-lh.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bh-lh.png&amp;diff=321"/>
		<updated>2018-12-26T11:37:40Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bh-lsh.png&amp;diff=322</id>
		<title>File:Olympus series bh microscope bh-lsh.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bh-lsh.png&amp;diff=322"/>
		<updated>2018-12-26T11:37:40Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bh-pc.png&amp;diff=323</id>
		<title>File:Olympus series bh microscope bh-pc.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bh-pc.png&amp;diff=323"/>
		<updated>2018-12-26T11:37:40Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bh-sh.png&amp;diff=324</id>
		<title>File:Olympus series bh microscope bh-sh.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bh-sh.png&amp;diff=324"/>
		<updated>2018-12-26T11:37:40Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bh-sv.png&amp;diff=325</id>
		<title>File:Olympus series bh microscope bh-sv.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bh-sv.png&amp;diff=325"/>
		<updated>2018-12-26T11:37:40Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bh-swc.png&amp;diff=326</id>
		<title>File:Olympus series bh microscope bh-swc.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bh-swc.png&amp;diff=326"/>
		<updated>2018-12-26T11:37:40Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bh-swtr.png&amp;diff=327</id>
		<title>File:Olympus series bh microscope bh-swtr.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Olympus_series_bh_microscope_bh-swtr.png&amp;diff=327"/>
		<updated>2018-12-26T11:37:40Z</updated>

		<summary type="html">&lt;p&gt;Test: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Test</name></author>
		
	</entry>
</feed>