<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>http://microwiki.org/wiki/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Azonenberg</id>
	<title>Microwiki - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="http://microwiki.org/wiki/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Azonenberg"/>
	<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php/Special:Contributions/Azonenberg"/>
	<updated>2026-04-04T16:10:31Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.31.1</generator>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=1003</id>
		<title>DCI Drive</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=1003"/>
		<updated>2019-09-19T04:39:31Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: /* Stage */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;DCI stepper motor driver.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Stage==&lt;br /&gt;
&lt;br /&gt;
The provided stage. Marked &amp;quot;DCI MC-001&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_Stage.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Bottom of stage has four holes in a 2x2 grid. Holes are tapped for 10-32 machine screws.&lt;br /&gt;
&lt;br /&gt;
ID of holes is 4.15 mm. &lt;br /&gt;
&lt;br /&gt;
Pitch of holes in short axis (direction of motion): 50.53 mm&lt;br /&gt;
&lt;br /&gt;
Pitch of holes in long axis: 79.55 mm&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Top of stage has six 10-32 holes in a 2x3 grid. Spacing in both axes is 50.53 mm.&lt;br /&gt;
&lt;br /&gt;
==Joystick==&lt;br /&gt;
&lt;br /&gt;
The stage is meant to be manually controlled via a joystick.&lt;br /&gt;
&lt;br /&gt;
The joystick module is a 2-layer PCB which generates step/direction pulses using one CD4046B PLL IC for each axis. This is clearly a prototype or low-volume product given that there are at least four obvious pieces of rework on the board.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_bottom.jpg|500px]] [[File:DCI_joystick_top.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
==Drive==&lt;br /&gt;
&lt;br /&gt;
The drive unit accepts step/direction pulses on a DA-15 D-sub connector. Only six of the 15 positions are loaded, configured as follows. All signals are 5V CMOS logic levels.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
!Pin number!!Wire color!!Function&lt;br /&gt;
|-&lt;br /&gt;
|1||Black||Ground&lt;br /&gt;
|-&lt;br /&gt;
|5||Orange||+10V power to joystick&lt;br /&gt;
|-&lt;br /&gt;
|9||Yellow||X axis step&lt;br /&gt;
|-&lt;br /&gt;
|10||Green||Y axis step&lt;br /&gt;
|-&lt;br /&gt;
|11||Red||X axis direction&lt;br /&gt;
|-&lt;br /&gt;
|12||Brown||Y axis direction&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_cable.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_drive_front.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
TODO: internal photos of the drive unit, back panel, etc&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=997</id>
		<title>DCI Drive</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=997"/>
		<updated>2019-09-05T03:22:07Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: Hole pattern&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;DCI stepper motor driver.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Stage==&lt;br /&gt;
&lt;br /&gt;
The provided stage. Marked &amp;quot;DCI MC-001&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_Stage.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Bottom of stage has four holes in a 2x2 grid. Holes are tapped for 10-32 machine screws.&lt;br /&gt;
&lt;br /&gt;
ID of holes is 4.15 mm. &lt;br /&gt;
&lt;br /&gt;
Pitch of holes in short axis (direction of motion): 50.53 mm&lt;br /&gt;
&lt;br /&gt;
Pitch of holes in long axis: 79.55 mm&lt;br /&gt;
&lt;br /&gt;
==Joystick==&lt;br /&gt;
&lt;br /&gt;
The stage is meant to be manually controlled via a joystick.&lt;br /&gt;
&lt;br /&gt;
The joystick module is a 2-layer PCB which generates step/direction pulses using one CD4046B PLL IC for each axis. This is clearly a prototype or low-volume product given that there are at least four obvious pieces of rework on the board.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_bottom.jpg|500px]] [[File:DCI_joystick_top.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
==Drive==&lt;br /&gt;
&lt;br /&gt;
The drive unit accepts step/direction pulses on a DA-15 D-sub connector. Only six of the 15 positions are loaded, configured as follows. All signals are 5V CMOS logic levels.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
!Pin number!!Wire color!!Function&lt;br /&gt;
|-&lt;br /&gt;
|1||Black||Ground&lt;br /&gt;
|-&lt;br /&gt;
|5||Orange||+10V power to joystick&lt;br /&gt;
|-&lt;br /&gt;
|9||Yellow||X axis step&lt;br /&gt;
|-&lt;br /&gt;
|10||Green||Y axis step&lt;br /&gt;
|-&lt;br /&gt;
|11||Red||X axis direction&lt;br /&gt;
|-&lt;br /&gt;
|12||Brown||Y axis direction&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_cable.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_drive_front.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
TODO: internal photos of the drive unit, back panel, etc&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH&amp;diff=996</id>
		<title>Olympus BH</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH&amp;diff=996"/>
		<updated>2019-09-05T02:57:57Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: /* Base plate */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
=Part list=&lt;br /&gt;
&lt;br /&gt;
==Model==&lt;br /&gt;
&lt;br /&gt;
TODO: add standard metallurgical&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Name!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_system1.jpg|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, cover] [[BHA]||Bottom illumination, removable nosepiece||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHB]]||Bottom illumination, fixed nosepiece||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHC]]||Bottom illumination, fixed nosepiece, integrated light source||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-02]]||Epi-illumination, sliding stanmd, BF, monocular||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-22]]||Epi-illumination, sliding stanmd, BF, binocular||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_bhmj_and_bhmj-n_bhmj.png|300 px]] &amp;lt;br /&amp;gt;Source: [instruction BHMJ/-N, 3] [[BHMJ-42]|| ||Epi-illumination, sliding stanmd, BF, trinocular||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-02-N]]||Epi-illumination, sliding stanmd, BF/DF, monocular||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-22-N]]||Epi-illumination, sliding stanmd, BF/DF, binocular||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-42-N]]||Epi-illumination, sliding stanmd, BF/DF, trinocular||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Objective==&lt;br /&gt;
&lt;br /&gt;
M is BF only.  Neo are BF/DF.  All are M25 threaded&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Part #!!Type!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
| ||[[M5X]]||Objective||5x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[M10X]]||Objective||10x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[M20X]]||Objective||20x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[M40X]]||Objective||40x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[Neo5X]]||Objective||5x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[Neo10X]]||Objective||10x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[Neo20X]]||Objective||20x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[Neo40X]]||Objective||40x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-RE]]||Nosepiece||Quintuple||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-RE]]||Nosepiece|| ||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-NRE]]||Nosepiece|| ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Illuminator==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Part #!!Type!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-MA]]||Illuminator (vertical)||Brightfield||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-RLA]]||Illuminator (vertical)||Brightfield and darkfield||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-lh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BH-LH]||Lamphouse||Tungsten, 30W||Pre-centered&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-LHM]]||Lamphouse||Tungsten||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-lsh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BH-LSH]||Lamphouse||Halogen 100W||Centerable&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-lh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BH-LH]||Lamphouse|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_ls30.png|100 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[LS30]||Bulb||6V, 30W tungsten||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_ls15.png|100 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[LS15]||Bulb||6V, 15W tungsten||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[FK5X]]||Eyepiece, photo||5x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[TF]]||Power supply||Transformer||voltage range?&lt;br /&gt;
|-&lt;br /&gt;
| ||[[45C]]||Filter||for what?||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_jc12v_100w.png|150 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[jc12v 100W]||Bulb||Halogen||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Observation tube==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Part #!!Type!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
| ||[[CH-M045]]||Observation tube||Monocular||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-swtr.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-SWTR]||Observation tube||Binocular w/ photo?||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-bi30_bi45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-BI30]||Observation tube||Binocular, 30 degree||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-bi30_bi45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-BI45]||Observation tube||Binocular, 45 degree||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-tr30_tr45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-TR30]||Observation tube||Binocular, 30 degree (w/ photo)||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-tr30_tr45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-TR45]||Observation tube||Binocular, 45 degree (w/ photo)||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BiWF10X]]||Eyepiece||HEP, paired||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_emm-vi.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[EMM-VI]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_pm-10-35a.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-10-35A]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_pm-10-35l2a.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-10-35L2A]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_pm-10-35m.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-10-35M]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_pm-6.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-6]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Misc==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Part #!!Type!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
|[[File:zoidberg_bh_neo_turret.jpg|200 px]] [[BH-RE]||Nosepiece||Quintuple||Neo objectives (M25)&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bha-f.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BHA-F]||Stand||Bottom illumination, removable nosepiece||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bhb-f.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BHB-F]||Stand||Bottom illumination, fixed nosepiece||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bhc-f.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BHC-F]||Stand||Bottom illumination, fixed nosepiece, integrated light||Lowest cost?&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-sv.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-SV]||Stage|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-cd.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-CD]||Condenser||Abbe||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-aac.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-AAC]||Condenser||Ach/Apla||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-ST]], [[BHMJ-F]]||Body/base||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[FK3.3X]]||Photo eyepiece|| ||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[32.5C]]||Blue filter||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_ah-ca.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[AH-CA]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_ah-fa.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[AH-FA]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-dcd.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-DCD]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-dcw.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-DCW]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-pc.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-PC]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-sh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-SH]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-swc.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-SWC]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=BHA/BHB/BHC configurations=&lt;br /&gt;
&lt;br /&gt;
[[File:olympus_series_bh_microscope_system1.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
Above: probably a BHA.  Source: [BH microscope, cover]&lt;br /&gt;
&lt;br /&gt;
Source: [BH microscope, 18]&lt;br /&gt;
&lt;br /&gt;
NOTE: -1, -2, etc are my notation for the color columns in [BH microscope, 18]&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Part #!!Type!!Description!!BHA-1!!BHA-2!!BHA-3!!BHA-4!!BHB-1!!BHB-2!!BHB-3!!BHB-4!!BHC-1!!BHC-2&lt;br /&gt;
|-&lt;br /&gt;
|[[BHA-F]]||Stand|| ||Y||Y||Y||Y|| || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BHB-F]]||Stand|| || || || || ||Y||Y||Y||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BHC-F]]||Stand|| || || || || || || || || ||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-RE]]||Nosepiece||Quintuple||Y||Y||Y||Y|| || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-LH]]||Lamphouse|| ||Y||Y||Y||Y||Y||Y||Y||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[LS30]]||Bulb||6V, 30W||Y||Y||Y||Y||Y||Y||Y||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[LS15]]||Bulb||6V, 15W|| || || || || || || || ||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-BI45]]||Observation tube||45 deg binocular|| ||Y|| ||Y|| ||Y|| ||Y|| ||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-TR45]]||Observation tube||45 deg trinocular||Y|| ||Y|| ||Y|| ||Y|| ||Y||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-SV]]||Stage|| ||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-CD]]||Condenser||Abbe|| || ||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-AAC]]||Condenser||Ach/Apla||Y||Y|| || || || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
| ||Objective||Achromat 4x, 10x, S-40x (spring), S-100x (spring, oil) set|| || ||Y||Y|| || ||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Objective||Plan achromat 4x, 10x, 40x (spring), 100x (spring, oil) set||Y||Y|| || ||Y||Y|| || || ||&lt;br /&gt;
|-&lt;br /&gt;
| ||Objective||Plan achromat 20x (spring)||Y||Y|| || || || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BiWF10X]]||Eyepiece||HEP, paired||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[FK5X]]||Eyepiece, photo||5x||Y|| ||Y|| ||Y|| ||Y|| ||Y||&lt;br /&gt;
|-&lt;br /&gt;
|[[45C]]||Filter||for what?|| || || || || || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
| ||Bulb||Spare bulb (2x)||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Fuse||Spare fuse (2x)||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Oil||Immersion oil||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Cover||Vintyl dust cover||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=BHMJ configurations=&lt;br /&gt;
&lt;br /&gt;
[[File:olympus_bhmj_and_bhmj-n_bhmj.png|300 px]]&lt;br /&gt;
&lt;br /&gt;
Above: A BHMJ, probably a BHMJ-42.  Source: [instruction BHMJ/-N, 3]&lt;br /&gt;
&lt;br /&gt;
Source: [instruction BHMJ/-N, 2]&lt;br /&gt;
&lt;br /&gt;
-N adds darkfield&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Part #!!Type!!Description!!BHMJ-02!!BHMJ-22!!BHMJ-42!!BHMJ-02-N!!BHMJ-22-N!!BHMJ-42-N&lt;br /&gt;
|-&lt;br /&gt;
|[[BHMJ-ST]], [[BHMJ-F]]||Body/base|| ||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-RE]]||Nosepiece|| ||Y||Y||Y|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-NRE]]||Nosepiece|| || || || ||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-MA]]||Illuminator (vertical)||Brightfield||Y||Y||Y|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-RLA]]||Illuminator (vertical)||Brightfield and darkfield|| || || ||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[CH-M045]]||Observation tube||Monocular||Y|| || ||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-BI45]]||Observation tube||Monocular|| ||Y|| || ||Y||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-TR45]]||Observation tube||Binocular (w/ photo)|| || ||Y|| || ||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-LHM]]||Lamphouse||Tungsten||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[LS15]]||Bulb||15W tungsten||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[TF]]||Power supply||Transformer||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[M5X]] &amp;lt;br /&amp;gt;[[M10X]] &amp;lt;br /&amp;gt;[[M20X]] &amp;lt;br /&amp;gt;[[M40X]]||Objective||Set||Y||Y||Y|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[Neo5X]] &amp;lt;br /&amp;gt;[[Neo10X]] &amp;lt;br /&amp;gt;[[Neo20X]] &amp;lt;br /&amp;gt;[[Neo40x]]||Objective||Set|| || || ||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||High eyepoint BiWF10X,paired eyepiece|| ||Y||Y|| ||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||High eyepoint WF10X eyepiece||Y|| || ||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[FK3.3X]]||Photo eyepiece|| || ||Y|| || ||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Stage plate||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Stage clips||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Eyepiece caps|| ||Y||Y|| ||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[32.5C]]||Blue filter||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Vinyl dust cover||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=Measurements=&lt;br /&gt;
Taken from Andrew Zonenberg's BHM unless otherwise stated.&lt;br /&gt;
&lt;br /&gt;
===Base plate===&lt;br /&gt;
Attaches to microscope frame with four M6x1.0 screws, 15 mm long, in a 2x2 hole pattern. Screw heads are 9.9 mm OD.&lt;br /&gt;
&lt;br /&gt;
Base plate has 6.7mm clearance holes, scope body is tapped.&lt;br /&gt;
[[File:Hole-pattern.png|none|thumb|BHM hole pattern]]&lt;br /&gt;
Approx 135 mm front-to-back from center of microscope frame to sample.&lt;br /&gt;
&lt;br /&gt;
=References=&lt;br /&gt;
&lt;br /&gt;
*Olympus Series BH System Microscope [BH microscope]: [http://www.alanwood.net/downloads/olympus-bh-bha-bhb-bhc-brochure.pdf]&lt;br /&gt;
*Olympus metallurgical microscopes instruction manual, models BHMJ &amp;amp; BHMJ-N [instruction BHMJ/-N]: [http://www.alanwood.net/downloads/olympus-bhmj-bhmj-n-instructions.pdf]&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:Hole-pattern.png&amp;diff=995</id>
		<title>File:Hole-pattern.png</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:Hole-pattern.png&amp;diff=995"/>
		<updated>2019-09-05T02:56:50Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Olympus BHM base plate drill pattern&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH&amp;diff=994</id>
		<title>Olympus BH</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH&amp;diff=994"/>
		<updated>2019-09-05T02:56:01Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: /* Base plate */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
=Part list=&lt;br /&gt;
&lt;br /&gt;
==Model==&lt;br /&gt;
&lt;br /&gt;
TODO: add standard metallurgical&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Name!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_system1.jpg|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, cover] [[BHA]||Bottom illumination, removable nosepiece||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHB]]||Bottom illumination, fixed nosepiece||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHC]]||Bottom illumination, fixed nosepiece, integrated light source||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-02]]||Epi-illumination, sliding stanmd, BF, monocular||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-22]]||Epi-illumination, sliding stanmd, BF, binocular||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_bhmj_and_bhmj-n_bhmj.png|300 px]] &amp;lt;br /&amp;gt;Source: [instruction BHMJ/-N, 3] [[BHMJ-42]|| ||Epi-illumination, sliding stanmd, BF, trinocular||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-02-N]]||Epi-illumination, sliding stanmd, BF/DF, monocular||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-22-N]]||Epi-illumination, sliding stanmd, BF/DF, binocular||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-42-N]]||Epi-illumination, sliding stanmd, BF/DF, trinocular||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Objective==&lt;br /&gt;
&lt;br /&gt;
M is BF only.  Neo are BF/DF.  All are M25 threaded&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Part #!!Type!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
| ||[[M5X]]||Objective||5x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[M10X]]||Objective||10x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[M20X]]||Objective||20x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[M40X]]||Objective||40x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[Neo5X]]||Objective||5x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[Neo10X]]||Objective||10x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[Neo20X]]||Objective||20x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[Neo40X]]||Objective||40x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-RE]]||Nosepiece||Quintuple||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-RE]]||Nosepiece|| ||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-NRE]]||Nosepiece|| ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Illuminator==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Part #!!Type!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-MA]]||Illuminator (vertical)||Brightfield||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-RLA]]||Illuminator (vertical)||Brightfield and darkfield||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-lh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BH-LH]||Lamphouse||Tungsten, 30W||Pre-centered&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-LHM]]||Lamphouse||Tungsten||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-lsh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BH-LSH]||Lamphouse||Halogen 100W||Centerable&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-lh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BH-LH]||Lamphouse|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_ls30.png|100 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[LS30]||Bulb||6V, 30W tungsten||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_ls15.png|100 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[LS15]||Bulb||6V, 15W tungsten||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[FK5X]]||Eyepiece, photo||5x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[TF]]||Power supply||Transformer||voltage range?&lt;br /&gt;
|-&lt;br /&gt;
| ||[[45C]]||Filter||for what?||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_jc12v_100w.png|150 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[jc12v 100W]||Bulb||Halogen||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Observation tube==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Part #!!Type!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
| ||[[CH-M045]]||Observation tube||Monocular||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-swtr.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-SWTR]||Observation tube||Binocular w/ photo?||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-bi30_bi45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-BI30]||Observation tube||Binocular, 30 degree||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-bi30_bi45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-BI45]||Observation tube||Binocular, 45 degree||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-tr30_tr45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-TR30]||Observation tube||Binocular, 30 degree (w/ photo)||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-tr30_tr45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-TR45]||Observation tube||Binocular, 45 degree (w/ photo)||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BiWF10X]]||Eyepiece||HEP, paired||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_emm-vi.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[EMM-VI]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_pm-10-35a.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-10-35A]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_pm-10-35l2a.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-10-35L2A]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_pm-10-35m.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-10-35M]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_pm-6.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-6]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Misc==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Part #!!Type!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
|[[File:zoidberg_bh_neo_turret.jpg|200 px]] [[BH-RE]||Nosepiece||Quintuple||Neo objectives (M25)&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bha-f.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BHA-F]||Stand||Bottom illumination, removable nosepiece||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bhb-f.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BHB-F]||Stand||Bottom illumination, fixed nosepiece||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bhc-f.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BHC-F]||Stand||Bottom illumination, fixed nosepiece, integrated light||Lowest cost?&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-sv.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-SV]||Stage|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-cd.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-CD]||Condenser||Abbe||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-aac.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-AAC]||Condenser||Ach/Apla||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-ST]], [[BHMJ-F]]||Body/base||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[FK3.3X]]||Photo eyepiece|| ||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[32.5C]]||Blue filter||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_ah-ca.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[AH-CA]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_ah-fa.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[AH-FA]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-dcd.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-DCD]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-dcw.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-DCW]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-pc.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-PC]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-sh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-SH]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-swc.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-SWC]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=BHA/BHB/BHC configurations=&lt;br /&gt;
&lt;br /&gt;
[[File:olympus_series_bh_microscope_system1.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
Above: probably a BHA.  Source: [BH microscope, cover]&lt;br /&gt;
&lt;br /&gt;
Source: [BH microscope, 18]&lt;br /&gt;
&lt;br /&gt;
NOTE: -1, -2, etc are my notation for the color columns in [BH microscope, 18]&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Part #!!Type!!Description!!BHA-1!!BHA-2!!BHA-3!!BHA-4!!BHB-1!!BHB-2!!BHB-3!!BHB-4!!BHC-1!!BHC-2&lt;br /&gt;
|-&lt;br /&gt;
|[[BHA-F]]||Stand|| ||Y||Y||Y||Y|| || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BHB-F]]||Stand|| || || || || ||Y||Y||Y||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BHC-F]]||Stand|| || || || || || || || || ||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-RE]]||Nosepiece||Quintuple||Y||Y||Y||Y|| || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-LH]]||Lamphouse|| ||Y||Y||Y||Y||Y||Y||Y||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[LS30]]||Bulb||6V, 30W||Y||Y||Y||Y||Y||Y||Y||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[LS15]]||Bulb||6V, 15W|| || || || || || || || ||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-BI45]]||Observation tube||45 deg binocular|| ||Y|| ||Y|| ||Y|| ||Y|| ||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-TR45]]||Observation tube||45 deg trinocular||Y|| ||Y|| ||Y|| ||Y|| ||Y||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-SV]]||Stage|| ||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-CD]]||Condenser||Abbe|| || ||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-AAC]]||Condenser||Ach/Apla||Y||Y|| || || || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
| ||Objective||Achromat 4x, 10x, S-40x (spring), S-100x (spring, oil) set|| || ||Y||Y|| || ||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Objective||Plan achromat 4x, 10x, 40x (spring), 100x (spring, oil) set||Y||Y|| || ||Y||Y|| || || ||&lt;br /&gt;
|-&lt;br /&gt;
| ||Objective||Plan achromat 20x (spring)||Y||Y|| || || || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BiWF10X]]||Eyepiece||HEP, paired||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[FK5X]]||Eyepiece, photo||5x||Y|| ||Y|| ||Y|| ||Y|| ||Y||&lt;br /&gt;
|-&lt;br /&gt;
|[[45C]]||Filter||for what?|| || || || || || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
| ||Bulb||Spare bulb (2x)||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Fuse||Spare fuse (2x)||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Oil||Immersion oil||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Cover||Vintyl dust cover||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=BHMJ configurations=&lt;br /&gt;
&lt;br /&gt;
[[File:olympus_bhmj_and_bhmj-n_bhmj.png|300 px]]&lt;br /&gt;
&lt;br /&gt;
Above: A BHMJ, probably a BHMJ-42.  Source: [instruction BHMJ/-N, 3]&lt;br /&gt;
&lt;br /&gt;
Source: [instruction BHMJ/-N, 2]&lt;br /&gt;
&lt;br /&gt;
-N adds darkfield&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Part #!!Type!!Description!!BHMJ-02!!BHMJ-22!!BHMJ-42!!BHMJ-02-N!!BHMJ-22-N!!BHMJ-42-N&lt;br /&gt;
|-&lt;br /&gt;
|[[BHMJ-ST]], [[BHMJ-F]]||Body/base|| ||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-RE]]||Nosepiece|| ||Y||Y||Y|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-NRE]]||Nosepiece|| || || || ||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-MA]]||Illuminator (vertical)||Brightfield||Y||Y||Y|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-RLA]]||Illuminator (vertical)||Brightfield and darkfield|| || || ||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[CH-M045]]||Observation tube||Monocular||Y|| || ||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-BI45]]||Observation tube||Monocular|| ||Y|| || ||Y||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-TR45]]||Observation tube||Binocular (w/ photo)|| || ||Y|| || ||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-LHM]]||Lamphouse||Tungsten||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[LS15]]||Bulb||15W tungsten||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[TF]]||Power supply||Transformer||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[M5X]] &amp;lt;br /&amp;gt;[[M10X]] &amp;lt;br /&amp;gt;[[M20X]] &amp;lt;br /&amp;gt;[[M40X]]||Objective||Set||Y||Y||Y|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[Neo5X]] &amp;lt;br /&amp;gt;[[Neo10X]] &amp;lt;br /&amp;gt;[[Neo20X]] &amp;lt;br /&amp;gt;[[Neo40x]]||Objective||Set|| || || ||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||High eyepoint BiWF10X,paired eyepiece|| ||Y||Y|| ||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||High eyepoint WF10X eyepiece||Y|| || ||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[FK3.3X]]||Photo eyepiece|| || ||Y|| || ||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Stage plate||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Stage clips||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Eyepiece caps|| ||Y||Y|| ||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[32.5C]]||Blue filter||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Vinyl dust cover||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=Measurements=&lt;br /&gt;
Taken from Andrew Zonenberg's BHM unless otherwise stated.&lt;br /&gt;
&lt;br /&gt;
===Base plate===&lt;br /&gt;
Attaches to microscope frame with four M6x1.0 screws, 15mm long, in a 2x2 hole pattern. Base plate has 6.7mm clearance holes, scope body is tapped.&lt;br /&gt;
&lt;br /&gt;
Back row: outside to outside 42.7 mm so center to center 36 mm&lt;br /&gt;
&lt;br /&gt;
Front row: outside to outside 50.5 mm so center to center 43.8 mm&lt;br /&gt;
&lt;br /&gt;
Row spacing (diagonal): outside to outside 46.9 mm so center to center 40.2 mm, 40mm row linear row spacing&lt;br /&gt;
&lt;br /&gt;
Screw heads are 9.9mm OD.&lt;br /&gt;
&lt;br /&gt;
Approx 135 mm front-to-back from center of microscope frame to sample&lt;br /&gt;
&lt;br /&gt;
=References=&lt;br /&gt;
&lt;br /&gt;
*Olympus Series BH System Microscope [BH microscope]: [http://www.alanwood.net/downloads/olympus-bh-bha-bhb-bhc-brochure.pdf]&lt;br /&gt;
*Olympus metallurgical microscopes instruction manual, models BHMJ &amp;amp; BHMJ-N [instruction BHMJ/-N]: [http://www.alanwood.net/downloads/olympus-bhmj-bhmj-n-instructions.pdf]&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH&amp;diff=993</id>
		<title>Olympus BH</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH&amp;diff=993"/>
		<updated>2019-09-05T02:49:03Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: /* Base plate */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
=Part list=&lt;br /&gt;
&lt;br /&gt;
==Model==&lt;br /&gt;
&lt;br /&gt;
TODO: add standard metallurgical&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Name!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_system1.jpg|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, cover] [[BHA]||Bottom illumination, removable nosepiece||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHB]]||Bottom illumination, fixed nosepiece||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHC]]||Bottom illumination, fixed nosepiece, integrated light source||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-02]]||Epi-illumination, sliding stanmd, BF, monocular||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-22]]||Epi-illumination, sliding stanmd, BF, binocular||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_bhmj_and_bhmj-n_bhmj.png|300 px]] &amp;lt;br /&amp;gt;Source: [instruction BHMJ/-N, 3] [[BHMJ-42]|| ||Epi-illumination, sliding stanmd, BF, trinocular||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-02-N]]||Epi-illumination, sliding stanmd, BF/DF, monocular||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-22-N]]||Epi-illumination, sliding stanmd, BF/DF, binocular||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-42-N]]||Epi-illumination, sliding stanmd, BF/DF, trinocular||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Objective==&lt;br /&gt;
&lt;br /&gt;
M is BF only.  Neo are BF/DF.  All are M25 threaded&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Part #!!Type!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
| ||[[M5X]]||Objective||5x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[M10X]]||Objective||10x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[M20X]]||Objective||20x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[M40X]]||Objective||40x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[Neo5X]]||Objective||5x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[Neo10X]]||Objective||10x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[Neo20X]]||Objective||20x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[Neo40X]]||Objective||40x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-RE]]||Nosepiece||Quintuple||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-RE]]||Nosepiece|| ||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-NRE]]||Nosepiece|| ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Illuminator==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Part #!!Type!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-MA]]||Illuminator (vertical)||Brightfield||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-RLA]]||Illuminator (vertical)||Brightfield and darkfield||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-lh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BH-LH]||Lamphouse||Tungsten, 30W||Pre-centered&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-LHM]]||Lamphouse||Tungsten||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-lsh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BH-LSH]||Lamphouse||Halogen 100W||Centerable&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-lh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BH-LH]||Lamphouse|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_ls30.png|100 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[LS30]||Bulb||6V, 30W tungsten||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_ls15.png|100 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[LS15]||Bulb||6V, 15W tungsten||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[FK5X]]||Eyepiece, photo||5x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[TF]]||Power supply||Transformer||voltage range?&lt;br /&gt;
|-&lt;br /&gt;
| ||[[45C]]||Filter||for what?||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_jc12v_100w.png|150 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[jc12v 100W]||Bulb||Halogen||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Observation tube==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Part #!!Type!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
| ||[[CH-M045]]||Observation tube||Monocular||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-swtr.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-SWTR]||Observation tube||Binocular w/ photo?||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-bi30_bi45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-BI30]||Observation tube||Binocular, 30 degree||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-bi30_bi45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-BI45]||Observation tube||Binocular, 45 degree||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-tr30_tr45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-TR30]||Observation tube||Binocular, 30 degree (w/ photo)||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-tr30_tr45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-TR45]||Observation tube||Binocular, 45 degree (w/ photo)||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BiWF10X]]||Eyepiece||HEP, paired||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_emm-vi.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[EMM-VI]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_pm-10-35a.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-10-35A]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_pm-10-35l2a.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-10-35L2A]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_pm-10-35m.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-10-35M]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_pm-6.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-6]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Misc==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Part #!!Type!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
|[[File:zoidberg_bh_neo_turret.jpg|200 px]] [[BH-RE]||Nosepiece||Quintuple||Neo objectives (M25)&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bha-f.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BHA-F]||Stand||Bottom illumination, removable nosepiece||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bhb-f.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BHB-F]||Stand||Bottom illumination, fixed nosepiece||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bhc-f.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BHC-F]||Stand||Bottom illumination, fixed nosepiece, integrated light||Lowest cost?&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-sv.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-SV]||Stage|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-cd.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-CD]||Condenser||Abbe||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-aac.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-AAC]||Condenser||Ach/Apla||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-ST]], [[BHMJ-F]]||Body/base||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[FK3.3X]]||Photo eyepiece|| ||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[32.5C]]||Blue filter||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_ah-ca.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[AH-CA]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_ah-fa.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[AH-FA]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-dcd.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-DCD]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-dcw.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-DCW]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-pc.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-PC]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-sh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-SH]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-swc.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-SWC]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=BHA/BHB/BHC configurations=&lt;br /&gt;
&lt;br /&gt;
[[File:olympus_series_bh_microscope_system1.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
Above: probably a BHA.  Source: [BH microscope, cover]&lt;br /&gt;
&lt;br /&gt;
Source: [BH microscope, 18]&lt;br /&gt;
&lt;br /&gt;
NOTE: -1, -2, etc are my notation for the color columns in [BH microscope, 18]&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Part #!!Type!!Description!!BHA-1!!BHA-2!!BHA-3!!BHA-4!!BHB-1!!BHB-2!!BHB-3!!BHB-4!!BHC-1!!BHC-2&lt;br /&gt;
|-&lt;br /&gt;
|[[BHA-F]]||Stand|| ||Y||Y||Y||Y|| || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BHB-F]]||Stand|| || || || || ||Y||Y||Y||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BHC-F]]||Stand|| || || || || || || || || ||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-RE]]||Nosepiece||Quintuple||Y||Y||Y||Y|| || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-LH]]||Lamphouse|| ||Y||Y||Y||Y||Y||Y||Y||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[LS30]]||Bulb||6V, 30W||Y||Y||Y||Y||Y||Y||Y||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[LS15]]||Bulb||6V, 15W|| || || || || || || || ||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-BI45]]||Observation tube||45 deg binocular|| ||Y|| ||Y|| ||Y|| ||Y|| ||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-TR45]]||Observation tube||45 deg trinocular||Y|| ||Y|| ||Y|| ||Y|| ||Y||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-SV]]||Stage|| ||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-CD]]||Condenser||Abbe|| || ||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-AAC]]||Condenser||Ach/Apla||Y||Y|| || || || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
| ||Objective||Achromat 4x, 10x, S-40x (spring), S-100x (spring, oil) set|| || ||Y||Y|| || ||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Objective||Plan achromat 4x, 10x, 40x (spring), 100x (spring, oil) set||Y||Y|| || ||Y||Y|| || || ||&lt;br /&gt;
|-&lt;br /&gt;
| ||Objective||Plan achromat 20x (spring)||Y||Y|| || || || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BiWF10X]]||Eyepiece||HEP, paired||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[FK5X]]||Eyepiece, photo||5x||Y|| ||Y|| ||Y|| ||Y|| ||Y||&lt;br /&gt;
|-&lt;br /&gt;
|[[45C]]||Filter||for what?|| || || || || || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
| ||Bulb||Spare bulb (2x)||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Fuse||Spare fuse (2x)||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Oil||Immersion oil||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Cover||Vintyl dust cover||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=BHMJ configurations=&lt;br /&gt;
&lt;br /&gt;
[[File:olympus_bhmj_and_bhmj-n_bhmj.png|300 px]]&lt;br /&gt;
&lt;br /&gt;
Above: A BHMJ, probably a BHMJ-42.  Source: [instruction BHMJ/-N, 3]&lt;br /&gt;
&lt;br /&gt;
Source: [instruction BHMJ/-N, 2]&lt;br /&gt;
&lt;br /&gt;
-N adds darkfield&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Part #!!Type!!Description!!BHMJ-02!!BHMJ-22!!BHMJ-42!!BHMJ-02-N!!BHMJ-22-N!!BHMJ-42-N&lt;br /&gt;
|-&lt;br /&gt;
|[[BHMJ-ST]], [[BHMJ-F]]||Body/base|| ||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-RE]]||Nosepiece|| ||Y||Y||Y|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-NRE]]||Nosepiece|| || || || ||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-MA]]||Illuminator (vertical)||Brightfield||Y||Y||Y|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-RLA]]||Illuminator (vertical)||Brightfield and darkfield|| || || ||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[CH-M045]]||Observation tube||Monocular||Y|| || ||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-BI45]]||Observation tube||Monocular|| ||Y|| || ||Y||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-TR45]]||Observation tube||Binocular (w/ photo)|| || ||Y|| || ||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-LHM]]||Lamphouse||Tungsten||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[LS15]]||Bulb||15W tungsten||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[TF]]||Power supply||Transformer||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[M5X]] &amp;lt;br /&amp;gt;[[M10X]] &amp;lt;br /&amp;gt;[[M20X]] &amp;lt;br /&amp;gt;[[M40X]]||Objective||Set||Y||Y||Y|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[Neo5X]] &amp;lt;br /&amp;gt;[[Neo10X]] &amp;lt;br /&amp;gt;[[Neo20X]] &amp;lt;br /&amp;gt;[[Neo40x]]||Objective||Set|| || || ||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||High eyepoint BiWF10X,paired eyepiece|| ||Y||Y|| ||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||High eyepoint WF10X eyepiece||Y|| || ||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[FK3.3X]]||Photo eyepiece|| || ||Y|| || ||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Stage plate||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Stage clips||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Eyepiece caps|| ||Y||Y|| ||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[32.5C]]||Blue filter||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Vinyl dust cover||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
=Measurements=&lt;br /&gt;
Taken from Andrew Zonenberg's BHM unless otherwise stated.&lt;br /&gt;
&lt;br /&gt;
===Base plate===&lt;br /&gt;
Attaches to microscope frame with four M6x1.0 screws, 15mm long, in a 2x2 hole pattern. Base plate has 6.7mm clearance holes, scope body is tapped.&lt;br /&gt;
&lt;br /&gt;
Back row: outside to outside 42.7 mm so center to center 36 mm&lt;br /&gt;
&lt;br /&gt;
Front row: outside to outside 50.5 mm so center to center 43.8 mm&lt;br /&gt;
&lt;br /&gt;
Row spacing (diagonal): outside to outside 46.9 mm so center to center 40.2 mm.&lt;br /&gt;
&lt;br /&gt;
Screw heads are 9.9mm OD.&lt;br /&gt;
&lt;br /&gt;
Approx 135 mm front-to-back from center of microscope frame to sample&lt;br /&gt;
&lt;br /&gt;
=References=&lt;br /&gt;
&lt;br /&gt;
*Olympus Series BH System Microscope [BH microscope]: [http://www.alanwood.net/downloads/olympus-bh-bha-bhb-bhc-brochure.pdf]&lt;br /&gt;
*Olympus metallurgical microscopes instruction manual, models BHMJ &amp;amp; BHMJ-N [instruction BHMJ/-N]: [http://www.alanwood.net/downloads/olympus-bhmj-bhmj-n-instructions.pdf]&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=Olympus_BH&amp;diff=992</id>
		<title>Olympus BH</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=Olympus_BH&amp;diff=992"/>
		<updated>2019-09-05T02:42:20Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: Added BHM measurements, photos coming soon&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;[[Category:Olympus]]&lt;br /&gt;
&lt;br /&gt;
=Part list=&lt;br /&gt;
&lt;br /&gt;
==Model==&lt;br /&gt;
&lt;br /&gt;
TODO: add standard metallurgical&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Name!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_system1.jpg|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, cover] [[BHA]||Bottom illumination, removable nosepiece||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHB]]||Bottom illumination, fixed nosepiece||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHC]]||Bottom illumination, fixed nosepiece, integrated light source||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-02]]||Epi-illumination, sliding stanmd, BF, monocular||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-22]]||Epi-illumination, sliding stanmd, BF, binocular||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_bhmj_and_bhmj-n_bhmj.png|300 px]] &amp;lt;br /&amp;gt;Source: [instruction BHMJ/-N, 3] [[BHMJ-42]|| ||Epi-illumination, sliding stanmd, BF, trinocular||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-02-N]]||Epi-illumination, sliding stanmd, BF/DF, monocular||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-22-N]]||Epi-illumination, sliding stanmd, BF/DF, binocular||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-42-N]]||Epi-illumination, sliding stanmd, BF/DF, trinocular||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Objective==&lt;br /&gt;
&lt;br /&gt;
M is BF only.  Neo are BF/DF.  All are M25 threaded&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Part #!!Type!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
| ||[[M5X]]||Objective||5x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[M10X]]||Objective||10x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[M20X]]||Objective||20x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[M40X]]||Objective||40x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[Neo5X]]||Objective||5x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[Neo10X]]||Objective||10x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[Neo20X]]||Objective||20x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[Neo40X]]||Objective||40x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-RE]]||Nosepiece||Quintuple||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-RE]]||Nosepiece|| ||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-NRE]]||Nosepiece|| ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Illuminator==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Part #!!Type!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-MA]]||Illuminator (vertical)||Brightfield||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-RLA]]||Illuminator (vertical)||Brightfield and darkfield||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-lh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BH-LH]||Lamphouse||Tungsten, 30W||Pre-centered&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BH-LHM]]||Lamphouse||Tungsten||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-lsh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BH-LSH]||Lamphouse||Halogen 100W||Centerable&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-lh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BH-LH]||Lamphouse|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_ls30.png|100 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[LS30]||Bulb||6V, 30W tungsten||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_ls15.png|100 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[LS15]||Bulb||6V, 15W tungsten||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[FK5X]]||Eyepiece, photo||5x||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[TF]]||Power supply||Transformer||voltage range?&lt;br /&gt;
|-&lt;br /&gt;
| ||[[45C]]||Filter||for what?||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_jc12v_100w.png|150 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[jc12v 100W]||Bulb||Halogen||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Observation tube==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Part #!!Type!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
| ||[[CH-M045]]||Observation tube||Monocular||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-swtr.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-SWTR]||Observation tube||Binocular w/ photo?||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-bi30_bi45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-BI30]||Observation tube||Binocular, 30 degree||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-bi30_bi45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-BI45]||Observation tube||Binocular, 45 degree||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-tr30_tr45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-TR30]||Observation tube||Binocular, 30 degree (w/ photo)||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-tr30_tr45.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[BH-TR45]||Observation tube||Binocular, 45 degree (w/ photo)||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BiWF10X]]||Eyepiece||HEP, paired||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_emm-vi.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[EMM-VI]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_pm-10-35a.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-10-35A]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_pm-10-35l2a.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-10-35L2A]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_pm-10-35m.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-10-35M]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_pm-6.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 15] [[PM-6]|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Misc==&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Image!!Part #!!Type!!Description!!Notes&lt;br /&gt;
|-&lt;br /&gt;
|[[File:zoidberg_bh_neo_turret.jpg|200 px]] [[BH-RE]||Nosepiece||Quintuple||Neo objectives (M25)&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bha-f.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BHA-F]||Stand||Bottom illumination, removable nosepiece||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bhb-f.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BHB-F]||Stand||Bottom illumination, fixed nosepiece||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bhc-f.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 9] [[BHC-F]||Stand||Bottom illumination, fixed nosepiece, integrated light||Lowest cost?&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-sv.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-SV]||Stage|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-cd.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-CD]||Condenser||Abbe||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-aac.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-AAC]||Condenser||Ach/Apla||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[BHMJ-ST]], [[BHMJ-F]]||Body/base||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[FK3.3X]]||Photo eyepiece|| ||&lt;br /&gt;
|-&lt;br /&gt;
| ||[[32.5C]]||Blue filter||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_ah-ca.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[AH-CA]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_ah-fa.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 11] [[AH-FA]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-dcd.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-DCD]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-dcw.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-DCW]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-pc.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-PC]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-sh.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-SH]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[File:olympus_series_bh_microscope_bh-swc.png|300 px]] &amp;lt;br /&amp;gt;Source: [BH microscope, 13] [[BH-SWC]|| ||&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=BHA/BHB/BHC configurations=&lt;br /&gt;
&lt;br /&gt;
[[File:olympus_series_bh_microscope_system1.jpg|300 px]]&lt;br /&gt;
&lt;br /&gt;
Above: probably a BHA.  Source: [BH microscope, cover]&lt;br /&gt;
&lt;br /&gt;
Source: [BH microscope, 18]&lt;br /&gt;
&lt;br /&gt;
NOTE: -1, -2, etc are my notation for the color columns in [BH microscope, 18]&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Part #!!Type!!Description!!BHA-1!!BHA-2!!BHA-3!!BHA-4!!BHB-1!!BHB-2!!BHB-3!!BHB-4!!BHC-1!!BHC-2&lt;br /&gt;
|-&lt;br /&gt;
|[[BHA-F]]||Stand|| ||Y||Y||Y||Y|| || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BHB-F]]||Stand|| || || || || ||Y||Y||Y||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BHC-F]]||Stand|| || || || || || || || || ||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-RE]]||Nosepiece||Quintuple||Y||Y||Y||Y|| || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-LH]]||Lamphouse|| ||Y||Y||Y||Y||Y||Y||Y||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[LS30]]||Bulb||6V, 30W||Y||Y||Y||Y||Y||Y||Y||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[LS15]]||Bulb||6V, 15W|| || || || || || || || ||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-BI45]]||Observation tube||45 deg binocular|| ||Y|| ||Y|| ||Y|| ||Y|| ||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-TR45]]||Observation tube||45 deg trinocular||Y|| ||Y|| ||Y|| ||Y|| ||Y||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-SV]]||Stage|| ||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-CD]]||Condenser||Abbe|| || ||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-AAC]]||Condenser||Ach/Apla||Y||Y|| || || || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
| ||Objective||Achromat 4x, 10x, S-40x (spring), S-100x (spring, oil) set|| || ||Y||Y|| || ||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Objective||Plan achromat 4x, 10x, 40x (spring), 100x (spring, oil) set||Y||Y|| || ||Y||Y|| || || ||&lt;br /&gt;
|-&lt;br /&gt;
| ||Objective||Plan achromat 20x (spring)||Y||Y|| || || || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BiWF10X]]||Eyepiece||HEP, paired||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[FK5X]]||Eyepiece, photo||5x||Y|| ||Y|| ||Y|| ||Y|| ||Y||&lt;br /&gt;
|-&lt;br /&gt;
|[[45C]]||Filter||for what?|| || || || || || || || || ||&lt;br /&gt;
|-&lt;br /&gt;
| ||Bulb||Spare bulb (2x)||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Fuse||Spare fuse (2x)||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Oil||Immersion oil||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Cover||Vintyl dust cover||Y||Y||Y||Y||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
=BHMJ configurations=&lt;br /&gt;
&lt;br /&gt;
[[File:olympus_bhmj_and_bhmj-n_bhmj.png|300 px]]&lt;br /&gt;
&lt;br /&gt;
Above: A BHMJ, probably a BHMJ-42.  Source: [instruction BHMJ/-N, 3]&lt;br /&gt;
&lt;br /&gt;
Source: [instruction BHMJ/-N, 2]&lt;br /&gt;
&lt;br /&gt;
-N adds darkfield&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable sortable&amp;quot; border=&amp;quot;1&amp;quot;&lt;br /&gt;
!Part #!!Type!!Description!!BHMJ-02!!BHMJ-22!!BHMJ-42!!BHMJ-02-N!!BHMJ-22-N!!BHMJ-42-N&lt;br /&gt;
|-&lt;br /&gt;
|[[BHMJ-ST]], [[BHMJ-F]]||Body/base|| ||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-RE]]||Nosepiece|| ||Y||Y||Y|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-NRE]]||Nosepiece|| || || || ||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-MA]]||Illuminator (vertical)||Brightfield||Y||Y||Y|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-RLA]]||Illuminator (vertical)||Brightfield and darkfield|| || || ||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[CH-M045]]||Observation tube||Monocular||Y|| || ||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-BI45]]||Observation tube||Monocular|| ||Y|| || ||Y||&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-TR45]]||Observation tube||Binocular (w/ photo)|| || ||Y|| || ||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[BH-LHM]]||Lamphouse||Tungsten||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[LS15]]||Bulb||15W tungsten||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[TF]]||Power supply||Transformer||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[M5X]] &amp;lt;br /&amp;gt;[[M10X]] &amp;lt;br /&amp;gt;[[M20X]] &amp;lt;br /&amp;gt;[[M40X]]||Objective||Set||Y||Y||Y|| || ||&lt;br /&gt;
|-&lt;br /&gt;
|[[Neo5X]] &amp;lt;br /&amp;gt;[[Neo10X]] &amp;lt;br /&amp;gt;[[Neo20X]] &amp;lt;br /&amp;gt;[[Neo40x]]||Objective||Set|| || || ||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||High eyepoint BiWF10X,paired eyepiece|| ||Y||Y|| ||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||High eyepoint WF10X eyepiece||Y|| || ||Y|| ||&lt;br /&gt;
|-&lt;br /&gt;
|[[FK3.3X]]||Photo eyepiece|| || ||Y|| || ||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Stage plate||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Stage clips||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Eyepiece caps|| ||Y||Y|| ||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|[[32.5C]]||Blue filter||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
| ||Vinyl dust cover||Y||Y||Y||Y||Y||Y&lt;br /&gt;
|-&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
= Measurements =&lt;br /&gt;
Taken from Andrew Zonenberg's BHM unless otherwise stated.&lt;br /&gt;
&lt;br /&gt;
=== Base plate ===&lt;br /&gt;
Attaches to microscope frame with four M6x1.0 screws, 15mm long, in a 2x2 hole pattern. Base plate has 6.7mm clearance holes, scope body is tapped.&lt;br /&gt;
&lt;br /&gt;
Back row: outside to outside 42.7 mm so center to center 36 mm&lt;br /&gt;
&lt;br /&gt;
Front row: outside to outside 50.5 mm so center to center 43.8 mm&lt;br /&gt;
&lt;br /&gt;
Row spacing (diagonal): outside to outside 46.9 mm so center to center 40.2 mm.&lt;br /&gt;
&lt;br /&gt;
Screw heads are 9.9mm OD.&lt;br /&gt;
&lt;br /&gt;
=References=&lt;br /&gt;
&lt;br /&gt;
*Olympus Series BH System Microscope [BH microscope]: [http://www.alanwood.net/downloads/olympus-bh-bha-bhb-bhc-brochure.pdf]&lt;br /&gt;
*Olympus metallurgical microscopes instruction manual, models BHMJ &amp;amp; BHMJ-N [instruction BHMJ/-N]: [http://www.alanwood.net/downloads/olympus-bhmj-bhmj-n-instructions.pdf]&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=965</id>
		<title>DCI Drive</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=965"/>
		<updated>2019-08-10T08:08:12Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: finally got the table looking right&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;DCI stepper motor driver.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Stage ==&lt;br /&gt;
&lt;br /&gt;
The provided stage. Marked &amp;quot;DCI MC-001&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_Stage.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
== Joystick ==&lt;br /&gt;
&lt;br /&gt;
The stage is meant to be manually controlled via a joystick.&lt;br /&gt;
&lt;br /&gt;
The joystick module is a 2-layer PCB which generates step/direction pulses using one CD4046B PLL IC for each axis. This is clearly a prototype or low-volume product given that there are at least four obvious pieces of rework on the board.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_bottom.jpg|500px]] [[File:DCI_joystick_top.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
== Drive ==&lt;br /&gt;
&lt;br /&gt;
The drive unit accepts step/direction pulses on a DA-15 D-sub connector. Only six of the 15 positions are loaded, configured as follows. All signals are 5V CMOS logic levels.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Pin number !! Wire color !! Function&lt;br /&gt;
|-&lt;br /&gt;
| 1          || Black      || Ground&lt;br /&gt;
|-&lt;br /&gt;
| 5          || Orange     || +10V power to joystick&lt;br /&gt;
|-&lt;br /&gt;
| 9          || Yellow     || X axis step&lt;br /&gt;
|-&lt;br /&gt;
| 10         || Green      || Y axis step&lt;br /&gt;
|-&lt;br /&gt;
| 11         || Red        || X axis direction&lt;br /&gt;
|-&lt;br /&gt;
| 12         || Brown      || Y axis direction&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_cable.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_drive_front.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
TODO: internal photos of the drive unit, back panel, etc&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=964</id>
		<title>DCI Drive</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=964"/>
		<updated>2019-08-10T08:07:44Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: even more table tweaks&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;DCI stepper motor driver.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Stage ==&lt;br /&gt;
&lt;br /&gt;
The provided stage. Marked &amp;quot;DCI MC-001&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_Stage.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
== Joystick ==&lt;br /&gt;
&lt;br /&gt;
The stage is meant to be manually controlled via a joystick.&lt;br /&gt;
&lt;br /&gt;
The joystick module is a 2-layer PCB which generates step/direction pulses using one CD4046B PLL IC for each axis. This is clearly a prototype or low-volume product given that there are at least four obvious pieces of rework on the board.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_bottom.jpg|500px]] [[File:DCI_joystick_top.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
== Drive ==&lt;br /&gt;
&lt;br /&gt;
The drive unit accepts step/direction pulses on a DA-15 D-sub connector. Only six of the 15 positions are loaded, configured as follows. All signals are 5V CMOS logic levels.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Pin number !! Wire color !! Function&lt;br /&gt;
|- | 1          || Black      || Ground&lt;br /&gt;
|- | 5          || Orange     || +10V power to joystick&lt;br /&gt;
|- | 9          || Yellow     || X axis step&lt;br /&gt;
|- | 10         || Green      || Y axis step&lt;br /&gt;
|- | 11         || Red        || X axis direction&lt;br /&gt;
|- | 12         || Brown      || Y axis direction&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_cable.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_drive_front.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
TODO: internal photos of the drive unit, back panel, etc&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=963</id>
		<title>DCI Drive</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=963"/>
		<updated>2019-08-10T08:07:17Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: more table edits&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;DCI stepper motor driver.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Stage ==&lt;br /&gt;
&lt;br /&gt;
The provided stage. Marked &amp;quot;DCI MC-001&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_Stage.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
== Joystick ==&lt;br /&gt;
&lt;br /&gt;
The stage is meant to be manually controlled via a joystick.&lt;br /&gt;
&lt;br /&gt;
The joystick module is a 2-layer PCB which generates step/direction pulses using one CD4046B PLL IC for each axis. This is clearly a prototype or low-volume product given that there are at least four obvious pieces of rework on the board.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_bottom.jpg|500px]] [[File:DCI_joystick_top.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
== Drive ==&lt;br /&gt;
&lt;br /&gt;
The drive unit accepts step/direction pulses on a DA-15 D-sub connector. Only six of the 15 positions are loaded, configured as follows. All signals are 5V CMOS logic levels.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Pin number !! Wire color !! Function&lt;br /&gt;
|- 1          || Black      || Ground&lt;br /&gt;
|- 5          || Orange     || +10V power to joystick&lt;br /&gt;
|- 9          || Yellow     || X axis step&lt;br /&gt;
|- 10         || Green      || Y axis step&lt;br /&gt;
|- 11         || Red        || X axis direction&lt;br /&gt;
|- 12         || Brown      || Y axis direction&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_cable.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_drive_front.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
TODO: internal photos of the drive unit, back panel, etc&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=962</id>
		<title>DCI Drive</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=962"/>
		<updated>2019-08-10T08:06:23Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: Fixed table&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;DCI stepper motor driver.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Stage ==&lt;br /&gt;
&lt;br /&gt;
The provided stage. Marked &amp;quot;DCI MC-001&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_Stage.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
== Joystick ==&lt;br /&gt;
&lt;br /&gt;
The stage is meant to be manually controlled via a joystick.&lt;br /&gt;
&lt;br /&gt;
The joystick module is a 2-layer PCB which generates step/direction pulses using one CD4046B PLL IC for each axis. This is clearly a prototype or low-volume product given that there are at least four obvious pieces of rework on the board.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_bottom.jpg|500px]] [[File:DCI_joystick_top.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
== Drive ==&lt;br /&gt;
&lt;br /&gt;
The drive unit accepts step/direction pulses on a DA-15 D-sub connector. Only six of the 15 positions are loaded, configured as follows. All signals are 5V CMOS logic levels.&lt;br /&gt;
&lt;br /&gt;
{|&lt;br /&gt;
! Pin number !! Wire color !! Function&lt;br /&gt;
| 1          || Black      || Ground&lt;br /&gt;
| 5          || Orange     || +10V power to joystick&lt;br /&gt;
| 9          || Yellow     || X axis step&lt;br /&gt;
| 10         || Green      || Y axis step&lt;br /&gt;
| 11         || Red        || X axis direction&lt;br /&gt;
| 12         || Brown      || Y axis direction&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_cable.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_drive_front.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
TODO: internal photos of the drive unit, back panel, etc&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=961</id>
		<title>DCI Drive</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=961"/>
		<updated>2019-08-10T08:05:36Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: changed image sizes&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;DCI stepper motor driver.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Stage ==&lt;br /&gt;
&lt;br /&gt;
The provided stage. Marked &amp;quot;DCI MC-001&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_Stage.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
== Joystick ==&lt;br /&gt;
&lt;br /&gt;
The stage is meant to be manually controlled via a joystick.&lt;br /&gt;
&lt;br /&gt;
The joystick module is a 2-layer PCB which generates step/direction pulses using one CD4046B PLL IC for each axis. This is clearly a prototype or low-volume product given that there are at least four obvious pieces of rework on the board.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_bottom.jpg|500px]] [[File:DCI_joystick_top.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
== Drive ==&lt;br /&gt;
&lt;br /&gt;
The drive unit accepts step/direction pulses on a DA-15 D-sub connector. Only six of the 15 positions are loaded, configured as follows. All signals are 5V CMOS logic levels.&lt;br /&gt;
&lt;br /&gt;
{|&lt;br /&gt;
! Pin number ! Wire color ! Function&lt;br /&gt;
| 1          | Black      | Ground&lt;br /&gt;
| 5          | Orange     | +10V power to joystick&lt;br /&gt;
| 9          | Yellow     | X axis step&lt;br /&gt;
| 10         | Green      | Y axis step&lt;br /&gt;
| 11         | Red        | X axis direction&lt;br /&gt;
| 12         | Brown      | Y axis direction&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_cable.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_drive_front.jpg|500px]]&lt;br /&gt;
&lt;br /&gt;
TODO: internal photos of the drive unit, back panel, etc&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=960</id>
		<title>DCI Drive</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=960"/>
		<updated>2019-08-10T08:05:12Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: corrected image sizes&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;DCI stepper motor driver.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Stage ==&lt;br /&gt;
&lt;br /&gt;
The provided stage. Marked &amp;quot;DCI MC-001&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_Stage.jpg|300px]]&lt;br /&gt;
&lt;br /&gt;
== Joystick ==&lt;br /&gt;
&lt;br /&gt;
The stage is meant to be manually controlled via a joystick.&lt;br /&gt;
&lt;br /&gt;
The joystick module is a 2-layer PCB which generates step/direction pulses using one CD4046B PLL IC for each axis. This is clearly a prototype or low-volume product given that there are at least four obvious pieces of rework on the board.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_bottom.jpg|300px]]&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_top.jpg|300px]]&lt;br /&gt;
&lt;br /&gt;
== Drive ==&lt;br /&gt;
&lt;br /&gt;
The drive unit accepts step/direction pulses on a DA-15 D-sub connector. Only six of the 15 positions are loaded, configured as follows. All signals are 5V CMOS logic levels.&lt;br /&gt;
&lt;br /&gt;
{|&lt;br /&gt;
! Pin number ! Wire color ! Function&lt;br /&gt;
| 1          | Black      | Ground&lt;br /&gt;
| 5          | Orange     | +10V power to joystick&lt;br /&gt;
| 9          | Yellow     | X axis step&lt;br /&gt;
| 10         | Green      | Y axis step&lt;br /&gt;
| 11         | Red        | X axis direction&lt;br /&gt;
| 12         | Brown      | Y axis direction&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_cable.jpg|300px]]&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_drive_front.jpg|300px]]&lt;br /&gt;
&lt;br /&gt;
TODO: internal photos of the drive unit, back panel, etc&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=959</id>
		<title>DCI Drive</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=DCI_Drive&amp;diff=959"/>
		<updated>2019-08-10T08:04:19Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: Created page with &amp;quot;DCI stepper motor driver.   == Stage ==  The provided stage. Marked &amp;quot;DCI MC-001&amp;quot;.  300  == Joystick ==  The stage is meant to be manually controlled via...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;DCI stepper motor driver.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Stage ==&lt;br /&gt;
&lt;br /&gt;
The provided stage. Marked &amp;quot;DCI MC-001&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_Stage.jpg|300]]&lt;br /&gt;
&lt;br /&gt;
== Joystick ==&lt;br /&gt;
&lt;br /&gt;
The stage is meant to be manually controlled via a joystick.&lt;br /&gt;
&lt;br /&gt;
The joystick module is a 2-layer PCB which generates step/direction pulses using one CD4046B PLL IC for each axis. This is clearly a prototype or low-volume product given that there are at least four obvious pieces of rework on the board.&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_bottom.jpg|300]]&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_top.jpg|300]]&lt;br /&gt;
&lt;br /&gt;
== Drive ==&lt;br /&gt;
&lt;br /&gt;
The drive unit accepts step/direction pulses on a DA-15 D-sub connector. Only six of the 15 positions are loaded, configured as follows. All signals are 5V CMOS logic levels.&lt;br /&gt;
&lt;br /&gt;
{|&lt;br /&gt;
! Pin number ! Wire color ! Function&lt;br /&gt;
| 1          | Black      | Ground&lt;br /&gt;
| 5          | Orange     | +10V power to joystick&lt;br /&gt;
| 9          | Yellow     | X axis step&lt;br /&gt;
| 10         | Green      | Y axis step&lt;br /&gt;
| 11         | Red        | X axis direction&lt;br /&gt;
| 12         | Brown      | Y axis direction&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_joystick_cable.jpg|300]]&lt;br /&gt;
&lt;br /&gt;
[[File:DCI_drive_front.jpg|300]]&lt;br /&gt;
&lt;br /&gt;
TODO: internal photos of the drive unit, back panel, etc&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:DCI_drive_front.jpg&amp;diff=958</id>
		<title>File:DCI drive front.jpg</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:DCI_drive_front.jpg&amp;diff=958"/>
		<updated>2019-08-10T08:01:01Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:DCI_joystick_cable.jpg&amp;diff=957</id>
		<title>File:DCI joystick cable.jpg</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:DCI_joystick_cable.jpg&amp;diff=957"/>
		<updated>2019-08-10T07:59:59Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:DCI_joystick_top.jpg&amp;diff=956</id>
		<title>File:DCI joystick top.jpg</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:DCI_joystick_top.jpg&amp;diff=956"/>
		<updated>2019-08-10T07:55:30Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:DCI_joystick_bottom.jpg&amp;diff=955</id>
		<title>File:DCI joystick bottom.jpg</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:DCI_joystick_bottom.jpg&amp;diff=955"/>
		<updated>2019-08-10T07:54:37Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
	<entry>
		<id>http://microwiki.org/wiki/index.php?title=File:DCI_Stage.jpg&amp;diff=954</id>
		<title>File:DCI Stage.jpg</title>
		<link rel="alternate" type="text/html" href="http://microwiki.org/wiki/index.php?title=File:DCI_Stage.jpg&amp;diff=954"/>
		<updated>2019-08-10T07:52:39Z</updated>

		<summary type="html">&lt;p&gt;Azonenberg: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Azonenberg</name></author>
		
	</entry>
</feed>