SEM I-O
Image | Vendor | Model | Year | kV | Gun | Resolution (nm) | Features | Manual | Schem | SW | Notes |
---|---|---|---|---|---|---|---|---|---|---|---|
ISI | Alpha 9 | Referenced in price sheet | |||||||||
Source: [UMT EA] |
ISI | CL-6 | |||||||||
Source: [DS130 DS130] |
ISI | DS 130 | 40 | 3 (top stage) 6 (bot stage) |
DS 130/1: Bottom Stage only DS 130/2: Top Stage only DS 130/3: Complete Top and Bottom Stage System | ||||||
Source: [dtradingpost ISI-40] |
ISI | ISI-40 SMS-2D |
TODO: index schematic list | ||||||||
ISI | ISI-60 | 1979 | Advert lists it as new the same time as the Super IIIA and I know the Super IIIA was around 1979 | ||||||||
ISI | ISI-60A | ||||||||||
ISI | ISI-100 | 1977 | 25? | LAB6 | 10? | "could handle 4-inch-diameter specimens" [1970s] | |||||
ISI | ISI-100N | ||||||||||
Source: [AMS SEM] |
ISI | ISI-SS60 | |||||||||
Source: private e-mail |
ISI | ISI M-7 | Very hard to find info on this unit | ||||||||
Source: [OSU MINISEM1] |
ISI | MSM-2 | 1973 | 30 | Tabletop [OSU MINISEM1] ] | ||||||
ISI | ISI SMS-1 ISI Super-Mini-SEM 1 |
1974 | 25 | 10 | Yes | "could accommodate samples up to 32 mm in diameter" [1970s] | |||||
ISI | ISI SMS-2 ISI Super-Mini-SEM 2 |
1975 | 25? | 10? | Yes | "increased the sample chamber size to 3 inches in diameter"[1970s] JM may have partial or full schematic | |||||
ISI | SMS-3A Super-Mini-SEM III "ISI Super III A " |
~1980 | 30 | WHP | 7 | Yes (alt) All |
Yes | ref ] | |||
Source: [PTLI ISI-SS40] |
ISI | SS-40 | Partial? | ||||||||
Source: Jean Drohé private communication |
ISI | SS-60 | Yes | ||||||||
ISI | SS-130 | Partial? | |||||||||
Source: [TNTech MSE] |
ISI | SR50 | |||||||||
Source: [Virago] |
ISI | SX30 | [Virago] | ||||||||
ISI | SX-30/E4 | 5, 15, 25 | 7 | See advert | |||||||
Source: [equipmatching] |
ISI | SX-40 | 30 |
6 | Yes | Thanks to Nathalie Renevier for the user manual! Specifications on page 67 | |||||
ISI | SX-60 | Mentioned on ds130 website but I can't find any other references to this model | |||||||||
ISI | SYSTEM-100A | ||||||||||
ISI | TV Mini-SEM (TV-MSM) Schematic: MRS-2 |
1976 | Yes | unit Year based off of schematic date | |||||||
Source: [eBay 231289327125] |
ISI | WB-6 | |||||||||
JEOL | ClairScope JASM-6200 | W/8nm (30kV) | Atmospheric ] | ||||||||
JEOL | JAMP-10 | ||||||||||
JEOL | JIB-4500 | Multibeam FIB | |||||||||
JEOL | JIB-4600F | Multibeam FIB | |||||||||
JEOL | JEM-100S | [1960s] ] | |||||||||
JEOL | JEM-ARM-1000 | 1983 | 1000 | "one-of-a-kind Ultrahigh Voltage EM for the Lawrence Berkeley Laboratories in California, where scientists were interested in atomic resolution" [1980s] | |||||||
JEOL | JFSM-30 | 1974 | FE | 3 | [1970s] | ||||||
JEOL | JRSM-50A | 1973 | "hot stage for examining samples at elevated temperatures" [1970s] | ||||||||
JEOL | JSM-1 | 50 | 50 | [1960s] | |||||||
JEOL | JSM-2 | 50 | [1960s] | ||||||||
JEOL | JSM-U | 50 | [1960s] | ||||||||
JEOL | JSM-35CF | ||||||||||
JEOL | JSM-35CFS | 1982/3? | [1980s] | ||||||||
JEOL | JSM-820 | ||||||||||
JEOL | JSM-840 | 1982/3? | 3 | "best i've gotten out of it was resolving ~60nm colloidal silica particles" [az] year: [1980s] ] | |||||||
JEOL | JSM-5200 | ||||||||||
JEOL | JSM-5400 | ||||||||||
JEOL | JSM-5800 | ||||||||||
JEOL | JSM-5900 | ||||||||||
Source |
JEOL | JSM-5900LV | 3nm @ 30kV (SEI) 5nm @30kV (BEI) |
||||||||
JEOL | JSM-5910 | ||||||||||
JEOL | JSM-6010LA | HV: 4nm @ 20kV (SE) LV: 5nm @ 20kV (BSE) |
|||||||||
JEOL | JSM-6010PLUS "JSM-6010PLUS InTouchScope" |
||||||||||
JEOL | JSM-6100 | ||||||||||
JEOL | JSM-6300F | CFE | 1.5 nm @ 30 kV | ||||||||
JEOL | JSM-6300LV | ||||||||||
JEOL | JSM-6300V | ||||||||||
JEOL | JSM-6340F | CFE | 2.5 nm @ 1 kV 1.2 nm @ 20 kV |
||||||||
JEOL | JSM-6390 | ||||||||||
JEOL | JSM-6390LV | ||||||||||
JEOL | JSM-6400 | ||||||||||
Source |
JEOL | JSM-6460 | ~2004 | ||||||||
JEOL | JSM-6510 | LV: 3nm @ 30kV (SE) | |||||||||
JEOL | JSM-6510LV | HV: 3nm @ 30kV (SE) LV: 4nm @ 30kV (BSE) |
|||||||||
JEOL | JSM-7100F | 1.2nm at 30kV | |||||||||
JEOL | JSM-7500F | x 25 to 1,000,000 (printed as a 120mm x 90mm micrograph) | |||||||||
JEOL | JSM-7610F | 1.0 nm (15 kV), 0.6 nm (30 kV) attainable in STEM | |||||||||
JEOL | JSM-7800F | 1.0nm at 15kV, 0.8nm at 15kV, GB mode | |||||||||
JEOL | JSM-IC25S | 1970's | [1970s] | ||||||||
JEOL | JSM-IC845 | 1982/3? | "capable of holding 6 inch semiconductor wafers" [1980s] | ||||||||
JEOL | JSM-IC848 | 1982/3? | "cold handle 9 inch wafers" [1980s] | ||||||||
JEOL | JSM IC-848A | ||||||||||
JEOL | JSM-IT300LV | HV: 3nm @ 30kV (SE) LV: 4nm @ 30kV (BSE) |
|||||||||
JEOL | JSM-T20 | ||||||||||
JEOL | JSM-T200 | ||||||||||
JEOL | JSM-T220 | 1986 | "auto-stigmator and auto-focus" [1980s] | ||||||||
JEOL | JSM-T330 | 1986 | "auto-stigmator and auto-focus" [1980s] | ||||||||
JEOL | JSM-T330A | ||||||||||
JEOL | JSM-U3 | 50 | 20 | [1960s] | |||||||
Source |
JEOL | JWS-7500E | |||||||||
JEOL | NeoScope | "10X to 60,000X (printed as a 128mm x 96mm micrograph)" | Benchtop | ||||||||
JEOL | T-200 | ||||||||||
JEOL | T-300 | May be able to get manual, contact me | |||||||||
Leica Cambridge | S 360FE | ||||||||||
Leica Cambridge | 260 | ||||||||||
Leica Cambridge | Stereoscan 150u | 1978 | 7 [manual] | ||||||||
Leica Cambridge | Stereoscan 240 | ||||||||||
Leica Cambridge | Stereoscan 430 | Yes | |||||||||
Leica Cambridge | Stereoscan 440 | Yes | |||||||||
Leo | 435VP | 4nm @ 30kV (HV) | |||||||||
Leo | 1530 | Yes | |||||||||
Leo | 1550 |